INSTALLATION
15)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.
Fig.
WARNING!
Do not overtighten the screw
Recommended to grip the wrench by the short side.
16)Verify that if the conversion is from NG to LPG, the screw must be re assembled with the red
WARNING!
Also check that the pilot
and main burner injectors are
appropriate for the gas type.
18)Reverse steps 5) to 2)
19)Attach the label "This unit has been converted to LPG" near or on top of the serial # decal.
20)Replace yellow "Natural Gas" label with red "Propane" label.
Installation of the DC Sparker:
21)Locate the Piezo Ignitor situated at the side of valve.
Piezo
Ignitor
24)I nstall the 3/4" nylon plug to cover up the hole on the mounting bracket.
25)Connect the DC spark generator wires to the SIT Valve with the screw which is provided in the kit.
Red
LPG Configuration
22)Remove the Piezo Ignitor by unscrewing the nut at the back of the mounting bracket.
26)Locate the ground lug at the receptical box, left of the unit.
Fig.5
Ignitor
Wire
17)
Fig. 6
Piezo
Ignitor
23)Disconnect the ignitor wire from the Piezo Ignitor and connect it to the D.C. Sparker
DC
Sparker
Ignitor
Wire
27)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.
Ground
wire from
kit
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace | 25 |