Regency G36D installation manual Removing Valve, Installing Valve

Page 37

MAINTENANCE

REMOVING VALVE

1)Shut off the gas supply.

2)Remove louvers.

3)Open and remove the fl ush door.

4)Remove logs.

5)Remove the burner assembly by removing the two Phillips head screws.

11)Removethe12Phillipsheadscrewssecuring the valve tray assembly in place.

INSTALLING VALVE

1)

Attach the valve to the valve bracket with

 

the 4 (m5x8 metric) screws provided.

2)

Reconnect the "gas out" fl are fi tting with an

 

11/16" wrench.

3)

Reconnect the "gas out" fl are nut with a

 

13/16" wrench.

4) Install piezo ignitor push button assembly

 

and reconnect wire.

screws

Valve Tray Assembly

12) Lift the entire assembly out.

6)Remove the burner assembly by sliding left and out.

7)Remove the rear log stand by removing the 2 screws.

Screws Rear Log Stand

 

13)

Undo the pilot tube from the valve with a

 

 

7/16" wrench.

 

14)

Undo the quick drop out thermocouple nut

 

 

on the valve with a 9mm (metric) wrench.

 

15)

Remove the Piezo ignitor wire and push

 

 

button assembly.

 

16)

Undo the "gas out" fl are nut with a 13/16"

8) Lift out the bottom base panel.

wrench.

 

17)

Undo the "gas out" fl are fi tting with an 11/16"

 

 

wrench.

 

18)

Remove the 4 Phillips head screws from

 

 

the sides of the valve bracket and remove

 

 

valve.

9)

Hint: If you are using black pipe, ensure

Disconnect the inlet gas line.

that there is a union by the valve,

 

 

10)

Disconnect the 2 TP wires and the 2 TH

otherwise removal will be almost

impossible.

 

wires from the valve.

 

 

5)

Reconnect the quick drop out thermocouple

 

nut with a 9mm wrench.

6)

Reconnect the pilot tube nut with a 7/16"

 

wrench.

7)

Scrape off the old gasket from the fl oor of the

 

fi rebox and from the valve tray assembly.

8)

Install a new gasket and reinstall the valve

 

tray assembly.

Note: Failure to install a new gasket may severely affect the appliance performance.

9)Reinstall the 12 hold down screws.

10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

11)Reinstall the bottom brick panel and the front log stand.

12)Install burner assembly

13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)

14)Fire up the unit temporarily

15)Check the manifold pressure.

16)Reinstall the logs and base panels as needed.

17)Close the door and replace the louvers.

18)Fire up the unit again and check for proper fl ame appearance and glow on logs.

Verify proper operation

after servicing.

UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace

37

Image 37
Contents 12/18/05 G36D Zero Clearance Direct Vent Gas FireplaceTo the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for G36D-NG1 Safety Label300 Certified for/Certifiée pour Canada and U.S.AInstallation Checklist InstallationImportant Message Save These Instructions Before YOU StartDiagram G36D Unit DimensionsLocating Your GAS Stove Manufactured Mobile Home Additional RequirementsMantel LEG Clearances ClearancesFraming Finishing Combustible Mantels Top Standoff Assembly Unit Assembly Prior to InstallationVenting Introduction Top Facing Support Side Nailing StripsExterior Vent Area where terminal is not permitedLocations Vertical TerminationVenting Secure Vent Rigid Pipe Venting Components ListAlternate Rigid Pipe Venting SystemsUltraGlow Direct Vent System Flex Rigid Pipe Venting Arrangements Horizontal TerminationsInstallation Rigid Pipe Venting Arrangements Vertical Terminations Installation Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Flex LinerVenting Arrangements Vertical Terminations I g h t Achieved Diagram 3aSnorkel Terminations Diagram Roof Pitch Firestop spacer must be installedCeiling to the position Continue to assemble pipe lengthsOffset Chart Installation ProceduresFor UltraGlow Direct Vent System Flex GAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationLPG Conversion Kit Contains Installation of LPG Conversion KitQty DC Sparker Kit Contains QtySparker Ignitor Wire Ignitor WireGround Wire from Kit Piezo IgnitorHeat Shield Install the 1/2 bushing to the heat shieldChain 02-75 02-55 02-52 LOG SET Installation02-53 02-51 02-54 Log indentation 5th Grate TabRear Grate Tab Front BracketsPlace embers in these 3 locations On the burner tray Install fl ush glass as per instructions in manualFlush Louvers Standard Flush DoorOptional Flush Trim Wall Switch Remote ControlThermostat Wire Table Wall ThermostatDo not cut the ground terminal off under any circumstances Wiring DiagramTo Remove the Fan Installing the Optional FANOpen the bottom louver door Operating Instructions Copy of the Lighting Plate Instructions Maintenance InstructionsNormal Operating Sounds of GAS Appliances Maintenance Removing Valve Installing ValveG36D Main Assembly Pilot Assembly Gasket Parts ListG36D Flush Front Assembly UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyExclusions Register your UltraGlow online at