Nilfisk-ALTO 7309021 user manual General guidelines for the dosage of detergents

Page 52

3.8.3 Outlet point with detergent trolley and foam lance, Outlet point D

1.Open/close handle on high-pressure cock

2.Quick-coupling

3.Trigger on spray handle

4.Safety lock

5.Quick-coupling for spray lance

7.Foam lance

10.Dosage scale

11.Dosage valve

12.Detergent containers

Outlet point with detergent trolley should be operated in the same way as outlet point A with foam injector - cf. section 3.8.2.

3.8.4 General guidelines for the dosage of detergents

The Nilfisk-ALTO detergent equipment may be used for all disinfectants and detergents suitable for use in high-pressure cleaning according to Nilfisk-ALTO instructions. (The pH value should lie between 4 and 14). Acids and lyes should not be used undiluted.

The supplier’s instructions and guidelines should be followed very closely, this also applies to rules on protective garments and drainage.

Detergents which have not specifically been specified for use in high- pressure cleaning should only be used after prior permission from Nilfisk-ALTO and possibly the supplier.

By using Nilfisk-ALTO detergents users are sure to have machinery, accessories and deter- gents which are compatible and which are a pre- requisite for optimal solutions to the cleaning tasks.

Nilfisk-ALTO can offer a wide range of effective substances for professional cleaning and disin- fection.The products are composed of substances which unite effectiveness with environmental considerations.

52

Image 52
Contents Deltabooster Deltabooster How to use the Deltabooster Product Description Layout of systemPage Deltabooster switchboard Model survey and main functionsC3K pumps Selection of system Number of PumpsLine Pressure Selection of Spray LanceTechnical data Identification of modelControl system Water tank2 C3K pump ClassificaDimensions, weight and total performance per system No. of pumps Model 44C3Location of the Deltabooster Installation requirements for water connection Differential pressure of solenoid valve measured in barDeltabooster control system Installation requirements for mains power connectionMax 125 a Location of pipelines/general instructions Pipe systemTypes of pipes standards Tuyauterie PipingComponentsRørledningskomponenter Fittings, standardsRohrleitungskomponenten-Elements Dimension Bezeichnung DesignationBezeichnung Designationdimension Rohrhalterung tuyauSupportRohrleitungskomponenten-Elements Kobber CopperDimensioning of pipe systems Page Examples Example 50 m 40 m 70 mPressure Drop BarExample 60 m 30 m 10 m M 80 mPressure DropRing system Example 20 m 40 m 30 m 60 m 30 m 15 m 80 mBar 10 bar Temperature compensation Mounting requirements and hintsBends/hose connections CompensationFixation AT Corners and TEE Connectors Mounting of Pipe LINES/GENERAL InstructionsMounting in Connection Socket RemountingOutlet points and accessories Outlet StationAccessories Detachable foam injectorBar black nozzle protection Multipressure spray lance systemBar grey nozzle protection Location Sketch Mounting base Control of filter in water tank Connection of inlet waterFilter Page Starting up/running Oil controlStart Venting of pumpsAdjustment of line pressure Venting of pipe systemHow to use the Deltabooster SafetyDo not Interfere with this Setting Save these instructions for laterModel survey Functional diagram Control switch / starting switch and stopping switch Main / emergency switchInstrument panel Control panel Setting and reading of Deltabooster Setting of water temperature On 50CConnection and disconnection of C3K pumps Both should be on for the operation of a single plantReading of hour meters Starting up/running in cf. Fig Page Multipressure spray lance system Operation after starting up outlet points and equipment Operation after starting upAdmixture of detergents After useGeneral guidelines for the dosage of detergents Maintenance Service intervals/oil changeWater filter CouplingsTrouble-shooting and possible correction Problem Possible cause CorrectionPortugal 7309021