Nilfisk-ALTO 7309021 user manual Outlet points and accessories, Outlet Station

Page 29

1.8Outlet points and accessories

Outlet point A is a high-pressure cock meant for permanent mounting. The high-pressure cock should be fitted straight on the pipe line by means of an 15 mm cutting ring connection.

If a DELTABOOSTER spray lance is wanted the quick-coupling for the high- pressure hose should be fitted straight on to outlet point A.

If equipment for the application of detergents is wanted a foam injector should be fitted between outlet point A and the quick-coupling on the high-pressure hose.

When using the detergent trolley the high-pressure hose may be fitted straight on to the outlet point A.

OUTLET STATION

AHigh-pressure cock

To be used for connection of detergent trolley, single foam injector or single DELTABOOSTER spray lance.

BFoam injector

To be fitted on high-pressure cock.To be used in conjunction with foam lance when detergents and disinfectants are to be applied.

Dosage from 1-5%.

CWall rack

Used in conjunction with outlet station A and detach able foam injector.

Capacity to take lance, two 25 l cans and 10 m high-pressure hose.

DDetergent trolley

May be connected to high-pressure cock. Capacity to take high-pressure cock with detachable foam injector (A+B+C) and floor washer.

29

Image 29
Contents Deltabooster Deltabooster How to use the Deltabooster Layout of system Product DescriptionPage Model survey and main functions Deltabooster switchboardC3K pumps Number of Pumps Selection of systemLine Pressure Selection of Spray LanceIdentification of model Technical dataWater tank Control system2 C3K pump ClassificaNo. of pumps Model 44C3 Dimensions, weight and total performance per systemLocation of the Deltabooster Differential pressure of solenoid valve measured in bar Installation requirements for water connectionMax 125 a Installation requirements for mains power connectionDeltabooster control system Types of pipes standards Pipe systemLocation of pipelines/general instructions PipingComponents TuyauterieRørledningskomponenter Fittings, standardsRohrleitungskomponenten-Elements Bezeichnung Designation DimensionRohrhalterung tuyauSupport Bezeichnung DesignationdimensionKobber Copper Rohrleitungskomponenten-ElementsDimensioning of pipe systems Page Example 50 m 40 m 70 m ExamplesPressure Drop Bar30 m 10 m M 80 m Example 60 mPressure DropBar 10 bar Example 20 m 40 m 30 m 60 m 30 m 15 m 80 mRing system Mounting requirements and hints Temperature compensationBends/hose connections CompensationMounting of Pipe LINES/GENERAL Instructions Fixation AT Corners and TEE ConnectorsRemounting Mounting in Connection SocketOutlet Station Outlet points and accessoriesDetachable foam injector AccessoriesBar grey nozzle protection Multipressure spray lance systemBar black nozzle protection Location Sketch Mounting base Filter Connection of inlet waterControl of filter in water tank Page Oil control Starting up/runningStart Venting of pumpsVenting of pipe system Adjustment of line pressureSafety How to use the DeltaboosterDo not Interfere with this Setting Save these instructions for laterModel survey Functional diagram Instrument panel Main / emergency switchControl switch / starting switch and stopping switch Control panel Setting and reading of Deltabooster On 50C Setting of water temperatureBoth should be on for the operation of a single plant Connection and disconnection of C3K pumpsReading of hour meters Starting up/running in cf. Fig Page Multipressure spray lance system Operation after starting up Operation after starting up outlet points and equipmentAfter use Admixture of detergentsGeneral guidelines for the dosage of detergents Service intervals/oil change MaintenanceWater filter CouplingsProblem Possible cause Correction Trouble-shooting and possible correctionPortugal 7309021