Nilfisk-ALTO 7309021 user manual Multipressure spray lance system, Bar black nozzle protection

Page 31

1.9Multipressure spray lance system

Spray lances with colour coding are used as standard equipment. The colour code indicates the water volume and pressure supplied by the specific lance.

The different water volumes and pressures depend on the high-pressure nozzle, pre-nozzle and spray lance fitted.

The spray lances for 120 and 160 bar respectively differ in that the spray lances for 120 bar are fitted with a GREY nozzle protection, whereas the spray lances for 160 bar are fitted with a BLACK nozzle protection.

Multipressure spray lances are available in 3 different lengths: 50 mm - 570 mm - 930 mm.

160 bar  (black nozzle protection)

No.

Colour

High-

Pre-

C3K pumps

Reactive power*)

No. of

 

 

pressure

nozzle

Pressure

Water vol.

N

kp

pumps

 

 

nozzle

diameter

bar

l/min

 

 

in oper.

 

 

 

 

 

 

 

 

 

1

White

1515

1.56

27

17

19

2.0

1

2

Black

1530

2.27

27

35

41

4.2

2

3

Brown

1511

1.73

50

17

26

2.6

1

4

Green

1520

2.35

53

33

56

5.7

2

5

Blue

1508

1.80

80

17

35

3.6

1

6

Red

1513

2.27

80

27

57

5.8

1.5

7

Orange

15075

2.08

107

17

38

3.9

1

8

Yellow

1511

2.50

107

26

60

6.2

1.5

9

Steel

1506

none

152

17

46

4.7

1

 

 

 

 

 

 

 

 

 

120 bar  (grey nozzle protection)

No.

1

2

3

4

5

6

7

8

9

Colour

White

Black

Brown

Green

Blue

Red

Orange

Yellow

Steel

High- Pre- pressure nozzle nozzle diameter

15165

1.68

1531

2.32

1511

1.73

1522

2.43

1509

1.88

1515

2.43

1508

2.15

1513

2.74

15075

none

C3K pumps Pressure Water vol.

bar l/min

20

17

20

32

40

16

40

32

60

16

60

26

8017

8027

11417

Reactive power*)

N kp

18

1.8

33

3.4

23

2.3

48

4.9

28

2.8

45

4.6

35

3.6

565.7

404.1

No. of pumps in oper.

1

2

1

2

1

1.5

1

1.5

1

*) As the reactive power describes an angle together with the spray lance the pistol handle is also affected by a torque power.

Alternative lances should only be mounted under the guidance of Nilfisk-ALTO staff.

31

Image 31
Contents Deltabooster Deltabooster How to use the Deltabooster Layout of system Product DescriptionPage Model survey and main functions Deltabooster switchboardC3K pumps Selection of Spray Lance Selection of systemNumber of Pumps Line PressureIdentification of model Technical dataClassifica Control systemWater tank 2 C3K pumpNo. of pumps Model 44C3 Dimensions, weight and total performance per systemLocation of the Deltabooster Differential pressure of solenoid valve measured in bar Installation requirements for water connectionDeltabooster control system Installation requirements for mains power connectionMax 125 a Location of pipelines/general instructions Pipe systemTypes of pipes standards Fittings, standards TuyauteriePipingComponents RørledningskomponenterRohrleitungskomponenten-Elements Bezeichnung Designation DimensionRohrhalterung tuyauSupport Bezeichnung DesignationdimensionKobber Copper Rohrleitungskomponenten-ElementsDimensioning of pipe systems Page Bar ExamplesExample 50 m 40 m 70 m Pressure DropDrop Example 60 m30 m 10 m M 80 m PressureRing system Example 20 m 40 m 30 m 60 m 30 m 15 m 80 mBar 10 bar Compensation Temperature compensationMounting requirements and hints Bends/hose connectionsMounting of Pipe LINES/GENERAL Instructions Fixation AT Corners and TEE ConnectorsRemounting Mounting in Connection SocketOutlet Station Outlet points and accessoriesDetachable foam injector AccessoriesBar black nozzle protection Multipressure spray lance systemBar grey nozzle protection Location Sketch Mounting base Control of filter in water tank Connection of inlet waterFilter Page Venting of pumps Starting up/runningOil control StartVenting of pipe system Adjustment of line pressureSave these instructions for later How to use the DeltaboosterSafety Do not Interfere with this SettingModel survey Functional diagram Control switch / starting switch and stopping switch Main / emergency switchInstrument panel Control panel Setting and reading of Deltabooster On 50C Setting of water temperatureBoth should be on for the operation of a single plant Connection and disconnection of C3K pumpsReading of hour meters Starting up/running in cf. Fig Page Multipressure spray lance system Operation after starting up Operation after starting up outlet points and equipmentAfter use Admixture of detergentsGeneral guidelines for the dosage of detergents Couplings MaintenanceService intervals/oil change Water filterProblem Possible cause Correction Trouble-shooting and possible correctionPortugal 7309021