Nilfisk-ALTO 7309021 user manual Deltabooster

Page 2

 

 

 

DELTABOOSTER

 

 

 

manual

 

Contents

 

 

1

 

Product description

4

 

1.1

Model survey and main functions

6

 

1.2

Selection of system

8

 

1.3

Technical data

9

 

 

1.3.0

Switchboard

10

 

 

1.3.1

Water tank

10

 

 

1.3.2

C3K pumps

10

 

 

1.3.3 Dimensions, weight and total performance for systems

11

 

1.4

Location: surroundings -frost, safety and service margins

12

 

1.5

Installation requirements for water connection

13

 

1.6

Installation requirements for mains power connection

14

 

1.7

Pipe system

15

 

 

1.7.1 Location of pipe lines/general instructions

15

 

 

1.7.2 Types of pipes, standards

15

 

 

1.7.3

Fittings, standards

16

 

 

1.7.4 Dimensioning of pipe systems, pressure drop graph

21

 

 

1.7.5

Examples

23

 

 

1.7.6 Mounting requirements and hints

26

 

1.8

Outlet points and accessories

29

 

1.9

Spray lance system

31

2

Instructions for assembly

32

 

2.1

Location of the DELTABOOSTER

32

 

2.2

Mounting base and tip over safety device

33

 

2.3

Connection of inlet water

34

 

 

2.3.1 Control of filter in water tank

34

2.4Connection of power between the DELTABOOSTER and the supply network

(Settings on the plant, see section 3.5)

35

2.5 Starting up / running in

36

2.5.1

Oil control

36

2.5.2

Start

36

2.5.3

Venting of pumps

36

2.5.4 Venting of pipe system

37

2.5.5 Adjustment of line pressure

37

2

Image 2
Contents Deltabooster Deltabooster How to use the Deltabooster Product Description Layout of systemPage Deltabooster switchboard Model survey and main functionsC3K pumps Line Pressure Selection of systemNumber of Pumps Selection of Spray LanceTechnical data Identification of model2 C3K pump Control systemWater tank ClassificaDimensions, weight and total performance per system No. of pumps Model 44C3Location of the Deltabooster Installation requirements for water connection Differential pressure of solenoid valve measured in barMax 125 a Installation requirements for mains power connectionDeltabooster control system Types of pipes standards Pipe systemLocation of pipelines/general instructions Rørledningskomponenter TuyauteriePipingComponents Fittings, standardsRohrleitungskomponenten-Elements Dimension Bezeichnung DesignationBezeichnung Designationdimension Rohrhalterung tuyauSupportRohrleitungskomponenten-Elements Kobber CopperDimensioning of pipe systems Page Pressure Drop ExamplesExample 50 m 40 m 70 m BarPressure Example 60 m30 m 10 m M 80 m DropBar 10 bar Example 20 m 40 m 30 m 60 m 30 m 15 m 80 mRing system Bends/hose connections Temperature compensationMounting requirements and hints CompensationFixation AT Corners and TEE Connectors Mounting of Pipe LINES/GENERAL InstructionsMounting in Connection Socket RemountingOutlet points and accessories Outlet StationAccessories Detachable foam injectorBar grey nozzle protection Multipressure spray lance systemBar black nozzle protection Location Sketch Mounting base Filter Connection of inlet waterControl of filter in water tank Page Start Starting up/runningOil control Venting of pumpsAdjustment of line pressure Venting of pipe systemDo not Interfere with this Setting How to use the DeltaboosterSafety Save these instructions for laterModel survey Functional diagram Instrument panel Main / emergency switchControl switch / starting switch and stopping switch Control panel Setting and reading of Deltabooster Setting of water temperature On 50CConnection and disconnection of C3K pumps Both should be on for the operation of a single plantReading of hour meters Starting up/running in cf. Fig Page Multipressure spray lance system Operation after starting up outlet points and equipment Operation after starting upAdmixture of detergents After useGeneral guidelines for the dosage of detergents Water filter MaintenanceService intervals/oil change CouplingsTrouble-shooting and possible correction Problem Possible cause CorrectionPortugal 7309021