Setting Trolley Close Position/
Connecting Door Arm
(Continued)
LOW HEADROOM:
Using the LOW HEADROOM TROLLEY POSITIONING CHART, refer to DIM “X” to set the distance from header to trolley, as shown in FIG. 1.5.
NOTE: Depending on your setup, you may or may not have to cut straight arm to accomplish trolley settings.
If adjustment of the trolley position is required, use the close travel adjustment screw located on the bottom of the opener. A 1/4 turn equals approximately 1” of trolley travel; turn clockwise to decrease distance (forward) and
LOW HEADROOM TROLLEY
POSITIONING CHART FOR
(MODELS 9100, 9400, 9600, 5120 & 5140)
DIM “X” | TYPE OF ARM | REFERENCE | |
BEING USED | ILLUSTRATIONS | ||
| |||
|
|
| |
20” | CURVED / | FIG. 1.6 | |
STRAIGHT | |||
|
| ||
|
|
| |
| OPTIONAL HOOKUP | ||
|
|
| |
10” - 14” | STRAIGHT | FIG. 1.6a | |
|
|
|
LOW HEADROOM TROLLEY
POSITIONING CHART FOR (MODEL 9700)
DIM “X” | TYPE OF ARM | REFERENCE | |
BEING USED | ILLUSTRATIONS | ||
| |||
|
|
| |
CURVED / | FIG. 1.6 | ||
STRAIGHT | |||
|
| ||
|
|
| |
| OPTIONAL HOOKUP | ||
|
|
| |
10” - 14” | STRAIGHT | FIG. 1.6a | |
|
|
|
NOTE: Proceed with “Connecting Door Arm To Door” Step 18, on page 14.
TRAVEL ADJUSTMENT |
| |
OPEN | CLOSE | Bottom Of Opener |
MORE | LESS |
|
MORE |
| |
|
| FIG. 1.4 |
| “X” |
|
| Low Headroom Track | |
|
| FIG. 1.5 |
Curved Arm |
| |
|
| Straight Arm |
| Cut Straight Arm To |
|
| Accomplish Trolley |
|
| Setting |
|
| FIG. 1.6 | FIG. 1.6a |
26Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need
You can reach us Toll Free at