Wayne-Dalton 3320B, 3324B, 3322B-Z, 3224C-Z, 3222C  Troubleshooting, MAINTENANCE/ Troubleshooting

Page 41

Troubleshooting

SYMPTOM

PROBABLE CAUSE

CORRECTIVE ACTION

Opener won’t work from wall button or radio control.

No power to opener.

Check cord to outlet, wall switch and circuit breaker.

 

Short circuit in wires to opener or wall button.

Isolate by disconnecting the wires at the opener from the wall

 

 

station.

 

Motor Protector trips open due to excessive use.

 

 

 

Allow motor to cool for 20 minutes and try again.

 

 

 

Opener works from wall button but not from radio control.

Radio control system non-operational.

Weak or dead battery in transmitter replace.

 

 

Security code not matched between receiver and transmitter

 

 

(see page 33)

 

 

If two or more transmitters don’t work, have motor control board

 

 

tested.

 

 

 

Door does not open and opener light fl ashes.

Something obstructing door travel.

Disconnect door from operator. Operate door by hand to locate

 

 

obstruction or call a service person.

 

Insuffi cient opening force.

 

 

 

Adjust opening force. (See Adj. #1 on page 32).

 

Build up of ice and snow around door.

 

 

 

Shovel and clear door area.

 

 

 

Door does not open fully and light does not fl ash.

Open limit not set properly.

Adjust open travel with screwdriver, turn counter-clockwise to

 

 

desired setting. 1/4 turn equals to 1” of travel (see Step 20).

 

 

 

Door stops and does not close fully.

Close limit not set properly.

Adjust close travel with screwdriver, turn clockwise to desired

 

 

setting. 1/4 turn equals 1” of travel (See Step 19).

 

 

 

Door closes and then returns to fully open position and

Door arm adjustment.

Adjust door arm (See Step 17 and 18).

opener light fl ashes.

 

 

 

Close travel adjustment is set beyond normal door position.

Adjust close travel with screwdriver, turn counter-clockwise to

 

 

desired setting. 1/4 turn equals 1” of travel (See Step 19).

 

Obstructions on fl oor.

 

 

 

Check for stones or ice under door and remove.

 

 

 

When activated with door in fully open position, door travels

Infrared safety sensors out of adjustment or defective.

Infrared safety sensors alignment should be checked per

for 1 second, stops, and returns to fully open position and

 

instructions. (See Step 16).

light begins to fl ash.

 

 

 

Obstructions in door opening.

Check for object blocking Infrared safety sensors.

 

 

 

Door reverses travel before reaching fully closed position

Activation of obstruction sensing system.

Check for binding in door travel (door “stops”, door tracks, etc).

and opener light fl ashes.

 

 

 

Loose or hanging objects on door activating Infrared safety

Remove objects.

 

sensor.

 

 

Insuffi cient closing force.

Adjust closing force. (See Adj. #1 on page 32).

 

 

 

Door fully opens and then light fl ashes.

Open limit is set too high and trolley is hitting the stop bolt.

Adjust open travel with screwdriver, turn clockwise to desired

 

 

setting. 1/4 turn equals to 1” of travel (see Step 20).

 

 

 

MAINTENANCE/ TROUBLESHOOTING

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need 35 You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Image 41
Contents Rev.3 7/19/2007 Important NoticeGarage Doors & Openers Package Contents Page Disconnect from power source and proceed to assembly Pre-InstallationDoor Test One Door Test TwoHomelink Compatibility Rolling Code Technology System FeaturesTools Needed Definition of key words used in this manual Table of ContentsAttaching Opener to Rail InstallationReinforce the Header Wall Positioning and Installing Front Wall BracketService Person End of Opener Positioning MotorAttach Unit to Front Wall Bracket AT Least 3 Feet LongMounting Opener End Proper InstallationMounting Door Bracket Installing LightManufacturer for Proper Reinforcing of Your DoorDoor can be Seen When Wired Wall Station Installation If IncludedWall Station Near or Next to Garage DoorWall Station Near or Next to Garage Door Wall Station Installation If IncludedWall Station OUT of the Reach Children and in a Location WhereNot adhere EntrapmentApply entrapment warning label in a Wired Infrared Safety Sensor Installation Infrared Safety Sensor Installation of Wiring for WiredConnecting Wired Infrared Safety Sensor to OpenerConnecting Trolley Connecting OpenerTo Latch Assembly Cord in AnywaySafety Sensors Alignment of Wired InfraredBe Closed by Continuously Fully Closed PositionTo Avoid Possible Injury or Setting Trolley Close PositionARM Connecting Door Arm to Door Setting Door Opening Travel Setting Door Close TravelStop Bolt Trolley Opener Result from Operating the DOOR/OPENER Contact Obstruction TestFatal Injury MAY Result Entry If Included Programming Wireless KeylessPossible Personal Injury To Prevent Door Damage orWood framing using the two screws Important Install ALL WallSurface inside garage MaterialsTo Avoid Electrical Shock Power ConnectionImportant Check Your Local Instructions IllustratedTools Needed Power Drill Socket Driver Optional InstallationsMounting Door Bracket To Series Door 14 x 5/8 self tapping screws as shown in FIGShown in FIG Must be Adjusted ProperlyWith Step 1/4 14 x 5/8 self-tapping screwsTrack Radius Being UsedLOW Headroom Standard LiftDIM Type of ARM Connecting Door ArmDetermine the WAYNE-DALTON Track Radius Being Used Trolley settingsDistance forward To Door , on Have to cut straight arm to accomplishLOW Headroom Trolley Positioning Chart for Door activation OperationRead and Follow ALL Instructions Operating the Wireless Wall Station Opener Controls Customizing the SettingsTeaching HomeLink to the opener Primary Programming for HomeLink to the ProdriveProgramming/Training HomeLink Unit Alternate Programming for HomeLink to the Prodrive Adjustment # 1 Opening and Closing Force AdjustmentsClosing Force Adjustment Opening Force AdjustmentWall Station Tools Needed NoneTransmitter Twice a Year MaintenanceBattery Replacement for Wall Station Symptom Probable Cause Corrective Action  TroubleshootingMAINTENANCE/ Troubleshooting # Per Unit Parts Breakdown Rail Assembly All ModelsDescription Description # Per Unit Parts Breakdown Opener Assembly And Accessories All ModelsWireless Keyless Entry Prodrive AccessoriesPre-drill 5/64 pilot hole Pre-drill 3/32 pilot holeDrill Template Thank you for your purchase Please Do Not Return This Product To The StoreReplacement labor Lifetime Limited WarrantyFCC and IC Statement Patent Information