Lochinvar 400 - 801 service manual Settings

Page 16

Service Manual

1Service

Parameter table

Table 1-4(continued from previous page) This table lists SMART SYSTEM control module parameters and where to access them

Menu

Sub

Description

See

User Access

Installer Access

 

 

 

 

Item

Page

Display

Modify

Display

Modify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

DHW Boiler Set Point

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

2

DHW Tank Set Point

21

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

3

Tank Set Point Differential

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

4

Boiler Set Point Offset

21

No

No

Yes

Yes

SETTINGS

 

 

 

 

 

 

 

 

 

5

Boiler Set Point Differential

21

No

No

Yes

Yes

E

 

 

 

 

 

 

 

6

SH/DHW Switching Time

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

7

DHW/SH Switching Time

21

No

No

Yes

Yes

DHW

 

 

 

 

 

 

 

 

 

 

8

Tank Minimum Set Point

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

9

Tank Maximum Set Point

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

10

DHW Type (Normal, Zone)

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

11

Fan Speed Limiting for Indirect DHW Tank

21

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

1

Low Outdoor Temperature

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

2

High Outdoor Temperature

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

3

SH1 Set Point at Low Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

4

SH1 Set Point at High Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

5

Outdoor Air Shutdown SH1

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

6

Outdoor Air Shutdown Differential SH1

23

No

No

Yes

Yes

RESET

 

 

 

 

 

 

 

 

 

7

Shift Reset Curve SH1

23

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

8

SH2 Set Point at Low Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

OUTDOOR

F

9

SH2 Set Point at High Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

10

Outdoor Air Shutdown SH2

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

11

Outdoor Air Shutdown Differential SH2

23

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

12

Shift Reset Curve SH2

23

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

13

SH3 Set Point at Low Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

14

SH3 Set Point at High Outdoor Temp

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

15

Outdoor Air Shutdown SH3

22

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

16

Outdoor Air Shutdown Differential SH3

23

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

17

Shift Reset Curve SH3

23

No

No

Yes

Yes

 

 

 

 

 

 

 

 

 

16

Image 16
Contents Models 400 Contents Handling ceramic fiber materials Please read before proceedingNiosh stated First Aid When servicing boiler What is in this manual? ServiceMaintenance TroubleshootingService Near boiler pipingKnight XL display Navigation DialControl inputs LOW Voltage Connection BoardSmart Control Module Control outputsAccess modes General OperationHow the boiler operates How the control module operatesOperation Display From previous page Sequence of Operation Display panel menu access Button Screen Operation Display StatusDisplay panel parameter access Parameter table GeneralSettings Reset Notification Temperature units C / F Viewable and changeable control parametersDate and Time Software VersionData Logging Temperature SettingsFunctions DHW Settings Outdoor Reset Anti-Cycling SH Ramp Delay Control modesControlling Sensor BMS Thermostat Input Active / InactiveCascade Offset Minimum On/Off TimeCirculation pumps Service Notification Service technician Maintenance Maintenance and annual startupOwner maintenance Maintenance Flue vent system and air piping Check water systemCheck expansion tank Check boiler relief valveCheck ignition ground wiring Check all boiler wiringCheck control settings Inspect ignition and flame sense electrodesCheck flame signal Cleaning boiler heat exchangerReview with owner Model Kit Part Component Number DescriptionTroubleshooting Before troubleshootingCheck control module fuses Check the followingNo Display No BurnerOperation Unit Does NotChecking temperature sensors Temperature ResistanceWire Color R/BK and Y Wire Color G and Y Resistance TemperatureNoisy No PumpBoiler Pump System Pump DHW PumpSwitch/LWCO FlowAnti-cycling Flame Fail IgnAuto Reset Flame SequenceHigh Limit Fan LowGV/Relay FailFan High Fan Speed HighFlue Temp High Delta T HighOutlet Temp HighRem Ctrl Flt Service BlkParameters Progr Watch Dog Error No Error StoredLow 24 vac Write EEPromCombustion Analysis Procedure Gas Valve AdjustmentOr Obstruction Gas Supply PressureModel Gas valve adjustment procedureModels 601 Page