Crown Boiler CWI103 II Specifications, Cwi Boilers - Generalconfiguration, Cwi Specifications

Page 3
II Specifications

II Specifications

FIGURE 1: CWI BOILERS - GENERALCONFIGURATION

TABLE 1: CWI SPECIFICATIONS

BASIC

NUMBER

 

NATURAL OR LP GAS *

 

 

 

 

 

 

 

WATER

 

HEATING

I=B=R NET

AFUE (%)

TANKLESS

 

 

 

 

 

BOILER

OF

INPUT

CAPACITY

RATING

STNDG.

INT.

HTR. RATING

DIMENSIONS (in.)

 

VOL.

MODEL

SECTIONS

(MBH)

(MBH)

(MBH)

PILOT

PILOT

(Gal/min)

"A"

"B"

"C"

 

"D"

(Gal)

CWI069

3

69

57

50

81.0

83.1

 

12 3/4

28

40 7/16

 

4

7.8

CWI103

4

103

86

75

81.3

83.1

2.50

16

28

40 7/16

 

5

10.0

CWI138

5

138

115

100

81.6

83.1

3.00

19 1/4

28

40 7/16

 

6

12.2

CWI172

6

172

144

125

81.8

83.2

3.50

22 1/2

28

40 7/16

 

6

14.4

CWI207

7

207

173

150

82.1

83.2

3.75/4.50

25 3/4

30

40 7/16

 

7

16.6

CWI241

8

241

202

175

81.1

83.2

3.75/4.75***

29

30

40 7/16

 

7

18.8

CWI276

9

276

232

200

81.4

83.2

4.00/5.25***

32 1/4

30

40 7/16

 

8

21.0

CWI310

10

310

259

225

83.5**

4.00/5.25***

35 1/2

30

45 7/16

 

8

23.2

CWI345

11

345

288

251

83.5**

4.00/5.25***

38 3/4

30

45 7/16

 

9

25.4

CWI379

12

379

316

275

83.5**

4.00/5.25***

42

30

45 7/16

 

9

27.6

*CWI345 AND CWI379 NOT AVAILABLE FOR USE WITH LP GAS

**COMBUSTION EFFICIENCY

***RATING WITH OPTIONAL "HIGH CAPACITY" TANKLESS HEATER

3

2

Image 3
Contents These instructions must be affixed on or adjacent to the boiler Gas-Fired Natural Draft Water Boilers INSTALLATION INSTRUCTIONSCWI Series ModelsI Product Description Table of ContentsII Specifications FIGURE 1 CWI BOILERS - GENERALCONFIGURATIONTABLE 1 CWI SPECIFICATIONS IV Locating the Boiler III Before InstallingV Air for Combustion and Ventilation For Buildings of Other than Unusually Tight Construction ForBuildingsofUnusuallyTightConstructionExample FIGURE3BOILERINSTALLEDINCONFINEDSPACE, ALL AIR FROM INSIDE FIGURE 4 ALL AIR FROM OUTDOORS, VENTILATED CRAWL SPACE AND ATTICFIGURE 5 ALL AIR FROM OUTDOORS VIA VENTILATED ATTIC FIGURE 6 ALL AIR FROM OUTDOORS, USING OPENINGS INTO BOILER ROOM VI Venting Removing an Existing Boiler from a Common Chimney FIGURE 9 VENT DAMPER INSTALLATION DETAILS FIGURE8 CWI BOILERTYPICALVENTSYSTEM INSTALLATION AND COMPONENTSVII Gas Piping VIII System Piping StandardPipingDANGER Piping for Special Situations 1413BOILERSIDEPIPING FIGURE 11 STANDARD BOILER PIPING FIGURE 12 INDIRECT WATER HEATERFIGURE13 BOILERBYPASSPIPING FIGURE15 BOILERPIPINGWITHCHILLER FIGURE14 ISOLATIONOFBOILERFROMSYSTEMWITHAHEATEXCHANGERIX TANKLESS HEATER PIPING A mixing valve does not eliminate the risk of scalding Feel water before showering or bathingFIGURE 17TANKLESSHEATERPIPING SingleZoneWiring IX WiringFIGURE 20 WIRING DIAGRAM, STANDING PILOT WITH TANKLESS HEATER Wiring Variations FACTORYWIRING NOT SHOWN - SEE FIGURES 18 FIGURE 22 CIRCULATOR ZONEWIRING USING HONEYWELLR845AsFACTORY BOILER WIRING NOT SHOWN - SEE FIGURES 18 FIGURE23ZONEWIRINGUSINGHONEYWELLV8043FZONEVALVESCWI Control System - Sequence of Operation Sequence of Operation, Standing Pilot, Less Tankless HeaterSequence of Operation, Standing Pilot, With Tankless Heater Sequence of Operation, Intermittent Ignition, With Tankless Heater Sequence of Operation, Intermittent Ignition, Less Tankless HeaterSafety Control Operation - Standing Pilot and Intermittent Ignition XI Start-up and CheckoutFIGURE 24 STANDING PILOT BURNER FLAME 2726Page Page LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH HONEYWELL FOR YOUR SAFETY READ BEFORE OPERATINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH ROBERTSHAW7000ERHC SERIES GAS VALVES STANDING PILOT VR8204 AND VR8304 SERIES GAS VALVES INTERMITTENT PILOT FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE7000DERHC SERIES GAS VALVES INTERMITTENT PILOT FIGURE 28b GASVALVEDETAIL-ROBERTSHAW 7000DERHC INTERMITTENT IGNITION FIGURE 27a GASVALVEDETAIL-HONEYWELLVR8200ORVR8300STANDINGPILOTXI Service and Maintenance Heat Exchanger Cleaning Procedure XIII Troubleshooting C1&C2? STARTNational Fuel Gas Code 5&6 onL2 ? STARTC1&C2? T&TV?C2 and Caution Read page 36 before attempting to use this chart Standing Pilot Ignition System Troubleshooting ChartIntermittent Ignition System Troubleshooting Chart XIV PARTS Page These Valves Piped in Series to Provide Redundent Shut-off 1/4 Pilot Tubing Used with Robertshaw Valves40mm BURNERS ONLY Page KEY # Page C. Heat Exchanger and Flue Collector Installation Appendix A Knockdown Boiler Assembly InstructionsA. Before Installing B. BaseAssembly PreparationFIGUREA1 BASE, HEAT EXCHANGER, FLUE COLLECTORASSEMBLY E. Control and Trim Installation D. Gas Valve InstallationFIGURE A2 JACKET INSTALLATION G. Complete Installation F. Electrical Wiring ConnectionsFIGURE A3 TAPPING LOCATIONS SEE TEXT FOR TAPPING USES P.O. Box 3633 I. StreetPhiladelphia