A.O. Smith 2600, 3400, 1700, 2000 instruction manual Status or Home, Configure Button

Page 53

STATUS OR HOME PAGE

A status (summary) page (Figure 54) is displayed when the S7999B display is connected. This status page appears on the S7999B when the Burner control icon is pressed on the “Home” page. The status page displays the current condition of the burner control and displays some of the more important configuration settings.

The boiler name associated with the burner control is displayed in the title on the status page.

Note: When the burner control has no boiler name defined, Modbus address is used to identify the boiler.

The initial status page displayed contains summary status information as shown in Figure 54. Any status information not applicable for the installation is grayed/blanked out on the screen.

Buttons on this screen include:

Configure: used to configure the burner control (password protected).

Operation: used to perform daily or frequent functions with the burner control, such as setpoint adjustment, etc.

Diagnostic: used to view burner control diagnostic information.

Details: used to view burner control detail status information.

History: used to view burner control history

Pump: used to expand the pump status information.

Modulation: used to toggle between status displays: pump, setpoints, and modulation.

Figure 54.  SUMMARY STATUS PAGE

CONFIGURE BUTTON

Pressing the Configure button (bottom left) on the Status page opens the Configuration page.

The S7999B Configuration page does not have a “Display Setup” button.

The configuration page allows the user to view and set parameters that define how the connected R7910A functions in the hydronic heating system. All parameters are factory configured and only a Field Service Agent must perform the configuration settings.

The configuration page contains a menu of parameters grouped into functional areas that the user selects for configuration (see Figure 55).

No specific order for configuration is required. All parameters are enabled for editing, though some may not be applicable (e.g., a configuration parameter may disable a control feature). Selecting a parameter group from the menu displays parameters exclusively applicable for the functional group on the page (see Figure 56). These parameters can be edited, and when the user is finished, control returns back to the configuration menu page.

Each parameter is displayed in its group. If there are more parameters than will fit on the screen, a vertical scroll bar allows the user to scroll up and down to view all parameters. The parameter name is displayed on the left and the current setting is displayed in the text box on the right.

Figure 55.  CONFIGURATION MENU PAGE

Figure 56.  SAMPLE CONFIGURATION PAGE

53

Image 53
Contents XP Boiler Table of Contents Important Definitions Safe INSTALLATION, USE and ServiceApprovals General Safety Model Identification IntroductionAbbreviations Used QualificationsOperating Characteristics Dimensions and Capacity DataDouble Heat Exchanger Boiler Rough in Dimensions Double Electrical Requirements RatingsXB Models FLOW, Head and Temperature Rise FLOW, Head and Temperature RiseSingle Heat Exchanger Boiler Components Features and ComponentsDouble Heat Exchanger Boiler Components Low water cutoff board and sensor probe Lwco Component DescriptionControl Components Water Temperature Limit Controls Flame Sensor Water Temperature SensorsMain Power Supply Switch LOW Water Cutoff Device LwcoHydronic System Boiler Installation ConsiderationsGeneral HOT Water Boiler System General Water Line Connections Internal ContaminantsClosed Water Systems Thermal ExpansionGAS Connections Explosion HazardGAS Supply Line Sizing Corrosive Materials and Contamination SourcesVAC Power Supply Wiring Field WiringPower Supply Check LOW Voltage Control WiringSuggested Pipe Size for Multiple GAS Appliances Natural GAS Required Ability General RequirementsLocation Replacing Existing Common Vented BoilerPanels and Covers Installation ClearancesChemical Vapor Corrosion LevelingOutdoor AIR Through ONE Opening Confined Space Outdoor AIR Through TWO OpeningsFresh AIR Openings for Confined Spaces Outdoor AIR Through TWO Vertical Ducts Outdoor AIR Through TWO Horizontal DuctsAIR from Other Indoor Spaces DuctsVenting AIR Inlet Pipe Materials Vent and AIR Pipe InstallationRequirements for Installation in Canada Horizontal Installation Requirements Vertical Installation RequirementsDirect Vent Installation Requirements Venting SupportsModels Vent KIT Numbers XB/XW TEE Models Vent KIT Numbers XB/XW Rain CAPModels Vent AIR Intake XB/XW KIT Numbers Rain CAP Elbow Models Vent AIR Intake XB/XW KIT Numbers TEE ElbowDirect VENT, Vertical Vent Horizontal Intake Power Vent Termination Clearances Sidewall Power VentDirect Vent Termination Clearances Sidewall Direct VentBELOW. Keep Clear of ALL Obstructions Termination Direct Vent Horizontal TerminationVENT/AIR Termination Locations Prepare ROOF/WALL Penetrations Direct Venting Vertical TerminationVertical ClearancesModel Vent Diameter Vent MIN. Length Vent MAX. Length Inch Condensate Neutralizer Condensate DisposalCondensate Trap XP Models AO Smith Condensate Neutralizer KIT NumbersGAS Pressure Requirements GAS Supply ConnectionsGAS Supply Pipe Connections Purging GAS Line Pipe Sizes for Propane GASCheck GAS Supply Inlet Pressure Check for GAS LeaksFilling HOT Water Supply Boiler Installation Filling and Purging of Heating Boiler InstallationBoiler Start UP and Operations Manifold Pressure ConnectionsCHECK/CONTROL Water Hardness Freeze Protection Hydronic Heating InstallationINSPECT/FILL Condensate System Water Hardness Medium 0-12 Grains PER Gallon XW ModelLighting and Operating Instructions Setting of the Test Mode AdjustmentHigh Fire Rate Overview Control SystemBurner Control System Burner Control Operation SpecificationsCommunications and Displays General Operational Sequence Lead LAG LL Master General Operation Lead LAGDomestic HOT Water Definitions FeaturesLocal Operator Interface Display System Mounting the S7999B OI Display and Power Supply Installation Instructions S7999B OI DisplayQuick Setup S7999B OI Display Common OI Display page Symbols POWER-UP ValidationStarting UP the S7999B OI Display NavigationS7999B Display page Flow Status or Home Configure ButtonLogin Configuration PasswordChange Parameter Settings KeyboardParameter Verify Example of Change ConfigurationHistory Button FAULT/ALARM HandlingData Comment Example of Hydronic History Operation Button Control Expanded Alert DetailSystem Configuration S7999B OI Display only Diagnostics ButtonHydronic Control ConfigurationSystem Synchronization S7999B OI Display only Code Description Recommended Troubleshooting Lockout Codes TroubleshootingReserved ILK OFF Flame Operation Faults 105 Flame detected out of sequence Adjust the LF switch while in this position Inspect the Combustion Pressure Switch to make Code Description Recommended Troubleshooting Lockout Codes Code Description Recommended Troubleshooting Lockout Codes Allowed Code DescriptionFan Parameter Errors Code Description Steam 20mA water temperature setting was invalid Abnormal Recycle Hardware flame bias delta high Eeprom DHW Plate Heat Exchanger Errors Maintenance Schedules Maintenance ProceduresGeneral Maintenance Inspect Boiler AreaAIR Filter BOX Burner MaintenanceBlower Compartment Condensate Removal System Venting MaintenanceHeat Exchanger Maintenance Handling Ceramic Fiber Materials Replacement PartsInlet DIA Piping DiagramsStorage Tank AOS Conditions and Exceptions Limited Warranty

3400, 1700, 2000, 2600 specifications

A.O. Smith, a leader in water heating solutions, has developed a range of high-efficiency water heaters that cater to various residential and commercial needs. Among their stellar offerings are the A.O. Smith 2600, 2000, 1700, and 3400 models, each boasting impressive features, cutting-edge technologies, and excellent energy efficiency.

The A.O. Smith 2600 model is designed for those who require a robust water heating solution with a capacity to handle high-demand scenarios. It utilizes a highly efficient heating element that provides rapid heating and maintains a steady output. The built-in smart control system allows users to monitor temperature settings and track energy consumption, ensuring optimal performance.

Next in line, the A.O. Smith 2000 is perfect for households that require a reliable and efficient water heater without compromising on space. This compact model integrates advanced thermal insulation that minimizes heat loss, coupled with a powerful heating element that ensures quick heating times. Its sleek design makes it suitable for various installations while maintaining aesthetic appeal.

The A.O. Smith 1700 model caters specifically to smaller residential needs but retains features that align with higher-end models. It incorporates state-of-the-art safety features, including overheat protection and a pressure relief valve. Its lightweight structure and ease of installation stand out, making it a recommended choice for those looking for efficient heating without extensive modifications to their plumbing systems.

Lastly, the A.O. Smith 3400 is a powerhouse designed for larger commercial applications. This model offers exceptional heating capacities and includes advanced technologies such as a digital display for easy monitoring and control. The robust build is complemented by a high-performance insulation system that significantly reduces energy consumption and operating costs.

All A.O. Smith water heaters, including the 2600, 2000, 1700, and 3400 models, feature corrosion-resistant materials ensuring longevity and durability. With their commitment to quality and innovation, A.O. Smith continues to provide water heating solutions that meet modern demands while emphasizing energy efficiency and user convenience. Whether for residential or commercial use, each model represents the pinnacle of reliability and performance in water heating technology.

In conclusion, A.O. Smith has established itself as a reliable choice for water heaters, with models that cater to diverse needs without compromising on efficiency or quality.