RTS ADAM Specifications, Board Performance, Configuration Requirements, Links Used, # TBX Cards

Models: ADAM

1 48
Download 48 pages 3.75 Kb
Page 9
Image 9
Specifications

Specifications

Board Performance

Throughput Per Link:

360Mb/sec

SFP Fiber Transceivers:

Voltage:

3.3V Rails

Standard Rate:

SONET OC12 or Gigabit Ethernet Recommended Parts:

Multi-Mode:

Finisar - FTLF8519P2BNL (Oxide VCSEL, Maximum reach of 550m) Single Mode:

Finisar - FTLF1422P1BTL (1310nm, Maximum reach 40km)

Fiber Cable Connector Type:

Multiple Mode Fiber LC–LC Duplex Connector – max length 500m (546.8 yd.)

Single Mode Fiber LC–LC Duplex Connector – max length 40km (24.9 miles)

Configuration Requirements

An MCII-e Master Controller card must be installed in the same frame as the TBX-Tribus. For more information, see the MCII-e User Manual which can be found at www.rtsintercoms.com.

TABLE 1. Systems Supported by the TBX-Tribus Card

Links Used

 

# TBX Cards

System

Frames Supported

Channels

 

per Frame

 

 

 

 

 

 

 

 

 

 

 

1

1

 

AIO-8

2

256

 

 

 

 

 

 

1

1

 

AIO-16

2

512

 

 

 

 

 

 

3

1

 

AIO-8

3

384

 

 

 

 

 

 

3

1

 

AIO-16

3

768

 

 

 

 

 

 

6

1

 

AIO-8

4

512

 

 

 

 

 

 

6

1

 

AIO-16

4

880

 

 

 

 

 

 

10

2

 

AIO-8

5

640

 

 

 

 

 

 

10

2

 

AIO-16

5

880

 

 

 

 

 

 

15

2

 

AIO-8

6

768

 

 

 

 

 

 

15

2

 

AIO-16

6

880

 

 

 

 

 

 

21

2

 

AIO-8

7

880

 

 

 

 

 

 

21

2

 

AIO-16

7

880

 

 

 

 

 

 

28

3

 

AIO-8

8

880

 

 

 

 

 

 

28

3

 

AIO-16

8

880

 

 

 

 

 

 

NOTE: The TBX–Tribus supports up to eight (8) frames in non-redundant mode. Slot 10 should be used if a third TBX– Tribus card is needed.