U.K. and IRELAND
Congratulations
By choosing a Bionaire™ humidifier, you have chosen one of the finest humidifiers on the market today
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS.
NOTE: Before reading these instructions, please refer to the corresponding illustrations
Descriptions (See fig 1/2)
A.Mist Chamber
B.Medicine Cup
C.Humidifier Housing
D.Power Knob
E.Night Light Control
FNight Light
GTank Handle
H.Tank
I.Tank Cap
J.Humidifier Base
K.Water Purification Filter
L.Water Tray
M.Safety Lock
N.Heating Element
SAFETY PRECAUTIONS
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1.Read all instructions before using the appliance.
2.To avoid fire or shock hazard, plug the appliance directly into an electrical outlet and fully insert the plug.
3.Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, or near radiator, stoves, or heaters.
4.DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. Do locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 10cm/4" away from the wall for best results.
5.WARNING: This humidifier produces hot steam and therefore should not be placed in an area where it is accessible to children. Never use a humidifier in a closed room. (i.e: doors and windows closed) as it may result in excessive humidity.
6.WARNING: Do not attempt to refill humidifier without first unplugging the unit from it's
electrical outlet. Be sure to pull by the plug and not the cord.
7.NEVER drop or insert any object into any openings. DO NOT place hands, face, or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet or place anything over it while the unit is operating.
8.DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or amaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.
9.Use appliance only for intended household use
as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by The Holmes Group, may cause hazards.
10.DO NOT use outdoors.
11.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for under the humidifier. NEVER place it on a surface that may become
damaged by exposure to water and moisture (i.e. finished floor).
12.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wallpaper.
13.Humidifier should be unplugged when not in use.
14.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. DO NOT attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged. Serious injury may result.
15.This humidifier requires regular maintenance to operate appropriately. Refer to cleaning and maintenance procedures.
16.NEVER use detergents, petrol, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
17.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF
18.Do not use humidifier in an area where humidity level is in excess of 55%.
19.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
2
20.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person.
PLEASE SAVE THESE INSTRUCTIONS Please note that this is an electrical appliance, and requires attention when in use.
How Your Warm Mist Humidifier Works
Your Bionaire™ Warm Mist Humidifier is designed to allow the proper amount of water to flow out of the tank and through the water purification filter.
The filter takes most of the minerals and sediment out of the water before the water enters the heating chamber where the Electronic Thermal Control heating element warms the water. Air is drawn in through the grill openings located in the back of the unit and mixed with steam in the misting chamber. The warm mist is then dispersed out of the top of the misting chamber through the outlet grill and into the room.
NOTE: A humidity level below 30% can be unhealthy and uncomfortable. The recommended humidity level is between 45%-55%.
PRE-OPERATING INSTRUCTIONS
1.Be sure the humidifier is disconnected from the electrical outlet and the power knob is in the 0 - off position.
2.Select a location for your humidifier, on a flat surface, about 10cm away from the wall. Do not place your humidifier on furniture. A floor location that will not be damaged by moisture is best.
3.Remove the water tank (see Figure 1). Remove the Water Purification Filter, and hold it under a cold running tap for at least 1 minute to ensure it is thoroughly wet. Then replace it in the water tray.
4.Make sure the water tray is free of foreign objects by removing the Mist Chamber. To remove this stack you must move the Safety Lock (M) that secures both parts in place. (Replace the Mist Chamber over the heating element and make sure that the Safety Lock knob is in the "Lock" position).
Filling the Water Tank
NOTE: This humidifier holds about 5.5 litres of water in the tank and humidifier base. The humidifier will produce up to 11.5 litres of moisture over a 24-hour period.
1.Be sure the humidifier is disconnected from the electrical outlet and the power knob is in the 0 - off position. Remove the water tank.
2.Twist off the tank cap located on the bottom of the reservoir by turning counter clockwise and fill the water tank with cool, fresh water. Do not fill with warm water as this may cause leaking.
3.After filling the tank, replace the tank cap by firmly turning clockwise and then replace the water tank on the base. The tank will immediately begin to empty into the base.
4.Plug the power cord into a convenient and suitable power supply.
OPERATING INSTRUCTIONS (See Fig 2)
IMPORTANT
When using the water purification filter in the humidifier for the first time, or after a period of non-use (i.e. 48 hours), pre-soak the filter under a cold running tap for 1 minute. Replace the filter in the unit and allow 5 minutes for the water to pass.
Then, carefully lift the water tank and check if the water tray (I) is 2/3 full of water. If not, replace the water tank and wait a further 5 minutes until the water reaches the desired level.
DO NOT switch on the humidifier until the water tray is 2/3 full of water.
1.Turn the power knob to the I position. It is normal for the humidifier to take about 2-3 minutes to warm up and begin to mist.
2.The Medicine Cup (B) is located on the top of the Mist Chamber (A). To use, pour designated humidifier medication into the groove.
DO NOT add medication to the water tank DO NOT add medication to the medicine cup when the unit is already operating.
Nightlight
1. To activate nightlight( ), move the knob to the on (I) position.
2.To maximize bulb life, turn the nightlight () off (O) during the day.
RESET PROCEDURE
NOTE: When the water tank is empty and the water in the Heating Chamber is almost empty, the re-fill light (red) will illuminate and the Automatic Shut-off will activate. The unit will not operate again until you refill the water tank and reset the humidifier.
1.Turn the power knob anti-clockwise on to RESET() .
2.Unplug the unit.
3.Remove and refill the water tank.Replace the tank onto the base.
4.Wait 5 minutes for the Automatic Shut-Off to reset.
5.After the 5 minutes, plug in the unit and turn
3