G. Installing Vertical Termination Cap
•Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of the pipe section while placing the outer collar of the cap over the outer flue of the pipe section.
•Secure the cap by driving three
Termination Cap
Brackets/ |
| (1 of three) |
| ||
|
| |
Bolts |
|
|
Storm
Collar
Screws
Caulk
Figure 10.15
H. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp.
•Connect both halves of the storm collar with two screws (see Figure 10.15).
•Wrap the storm collar around the exposed pipe section closest to the roof and align brackets. Insert a bolt (provided) through the brackets and tighten the nut to complete the storm collar assembly. Make sure the collar is tight against the pipe section.
•Slide the assembled storm collar down the pipe section until it rests on the roof flashing (see Figure 10.16).
•Caulk around the top of the storm collar (see Figure 10.15).
Figure 10.15 Assembling the Storm Collar
Figure 10.16 Assembling the Storm Collar Around the Pipe