For Vertical Terminations - To locate the flue and install the flue sections:
• Locate and mark the flue centerpoint on the underside of |
the roof, and drive a nail through the centerpoint. |
• Make the outline of the roof hole around the centerpoint |
nail. |
• The size of the roof hole framing dimensions depend on the |
pitch of the roof. There MUST BE a 25.4mm clearance |
from the vertical flue pipe to combustible materials. |
• Mark the roof hole accordingly. |
• Cover the opening of the installed flue pipes. |
To seal the roof hole, and to divert rain and snow from the flue system:
•Attach a flashing to the roof using nails, and use a non- hardening mastic around the edges of the flashing base where it meets the roof.
•Attach a storm collar over the flashing joint to form a
•Slide the termination cap over the end of the flue pipe and snap into place.
• Cut and frame the roof hole. |
• Use framing lumber the same size as the roof rafters |
and install the frame securely. Flashing anchored to the |
frame must withstand heavy winds. |
• Continue to install concentric flue sections up through |
the roof hole (for inside flue installations) or up past the |
roof line until you reach the appropriate distance above |
the roof (for outside terminations). |
!WARNING: FOLLOWING NATIONAL REGU- LATIONS AND CODES OF PRACTICE FOR
MINIMUM CLEARANCES FROM GAS TERMINALS, AND PLACEMENT OF GAS TERMINAL.
TERMINATION
CAP
50.8 cm | VERTICAL |
| |
| WALL |
LOWEST
DISCHARGE
OPENING
X
30.5 cm
ROOF PITCH IS X/ 30.5 cm
H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING
NOTE: This also pertains to vertical flue systems installed on the outside of the building.
Roof Pitch | H (min.) |
flat to 6/12 | 305 mm (1.0 ft.)* |
6/12 to 7/12 | 381 mm (1.25 ft.)* |
over 7/12 to 8/12 | 458 mm (1.5 ft.)* |
over 8/12 to 9/12 | 610 mm (2.0 ft.)* |
over 9/12 to 10/12 | 762 mm (2.5 ft.)* |
over 10/12 to 11/12 | 991 mm (3.25 ft.) |
over 11/12 to 12/12 | 1.2 m (4.0 ft.) |
over 12/12 to 14/12 | 1.5 m (5.0 ft.) |
over 14/12 to 16/12 | 1.9 m (6.0 ft.) |
over 16/12 to 18/12 | 2.2 m (7.0 ft.) |
over 18/12 to 20/12 | 2.3 m (7.5 ft.) |
over 20/12 to 21/12 | 2.5 m (8.0 ft.) |
* 91.4 cm minimum in snow regions
Figure 25. Minimum Height from Roof to Lowest Discharge Opening