Hearth and Home Technologies LCOR-HVB-CE Wiring the Fireplace, Finishing, Optional Accessories

Page 34

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

For Standing Pilot Ignition Wiring

Appliance Requirements

Optional Accessories

Optional remote control kits require that 230 VAC be wired to the facto- ry installed junction box before the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on a wall. Run a maximum of 780cm or less length of 0.102 cm diameter minimum wire and connect it to the fireplace ON/OFF switch pigtails.

!WARNING: DO NOT CONNECT 230 VAC TO THE GAS CONTROLVALVE

OR THE APPLIANCE WILL MALFUNC- TION AND THE VALVE WILL BE DE- STROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DIS- CONNECTION WHEN SERVICING CON- TROLS. WIRING ERRORS CAN CAUSE IM- PROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SER- VICING.

Step 9. Finishing

Figure 30 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 4 and

5for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front.

!

WARNING: WHEN FINISHING THE FIREPLACE, NEVER

OBSTRUCT OR MODIFY THE AIR INLET/OUTLET GRILLES

 

IN ANY MANNER.

 

 

CAUTION: IF JOINTS BETWEEN THE FIN- ISHED WALLS AND THE FIREPLACE SUR- ROUND (TOP AND SIDES) ARE SEALED, A 150° C. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON- COMBUSTIBLE MATERIAL (USING 150° C.

MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND (SEE FIGURE 31).

 

MANTEL

305mm

 

 

280mm

 

254mm

 

228mm

 

 

204mm

 

 

178mm

 

 

153mm

407mm

 

127mm

 

381mm

102mm

356mm

 

 

77mm

 

331mm

51mm

 

305mm

280mm

25.4mm

254mm

 

 

229mm

 

 

204mm

 

 

178mm

 

153mm

 

127mm

 

 

HOOD

NOTE: 305mm (12 in.) mantel at 407mm (16 in.) above hood.

Figure 30.

Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles above Fireplace

NOTE: Sheetrock or other combustible material such as wood can be placed on the top edge and sides of the fireplace.

 

ST-HVB-CE

 

TOP EDGE

 

SIDE EDGE

 

0” GAP

PIER-HVB-CE and L&RCOR-HVB-CE

 

TOP EDGE

 

SIDE EDGE

 

0” GAP

Figure 31.

Sealant Material

34

Heat & Glo • PIER/ST/L&RCOR-HVB-CE2068-900 Rev. H • 6/07

Image 34
Contents 0087 Safety and Warning Information Table of Contents PIER-HVB-CE NG, LP Exploded Parts Diagram PIER-HVB-CEST-HVB-CE ST-HVB-CE LCOR-HVB-CE LCOR-HVB-CE RCOR-HVB-CE RCOR-HVB-CE Valve Assembly RCOR-HVB-CE ÍAppliance Certification Installation RegulationsPre-install Preparation CertificationDiagram of the PIER-HVB-CE Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07Diagram of the ST-HVB-CE Diagram of the LCOR-HVB-CE and RCOR-HVB-CE Framing the Fireplace Fireplace Dimensions and LocationsLocating the Fireplace Clearance RequirementsModel AT Each Joint Identifying Flue Components Installing the Flue SystemFlue System Approvals Terminations KitsStraight OUT Horizontalflueing Max. RunFlueing with One 90 Elbow Flueing with Two 90 Elbows Propane / Butane Flueing with TWO 90 Elbows Flueing with three 90 elbows + H1 FT + V1 FT Installing Flue Components Attach the First Flue Component to the Starting CollarsContinue Adding Flue Components Install Support BracketsCombustibles inside the framed firestop opening Ceiling Firestop Ceiling Side Trapezoid Termination CapMinimum Height from Roof to Lowest Discharge Opening Vent Termination Minimum Clearances Gas Control System Positioning, Leveling, and Securing the FireplaceSecuring of a Fireplace Gas Pressure Requirements Gas Supply LineNatural Gas Wall Switch Wiring the FireplaceOptional Accessories FinishingInstalling the Trim Installing Trim, Logs & Ember MaterialLog placement Attachment of Lower Door AssemblyHeat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 3 4 Only for Model LCOR-HVB-CEHeat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Before Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceReplacing old ember material Fireplace MaintenanceCleaning Glass Door Checking Flame Patterns, Flame Height5Troubleshooting Troubleshooting Be Placed in this Opening