Hearth and Home Technologies ST-HVB-CE, RCOR-HVB-CE, PIER-HVB-CE, LCOR-HVB-CE manual St-Hvb-Ce

Page 7

(NG, LP) Exploded Parts Diagram

ST-HVB-CE

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

ITEM

 

COMMON PART

SERIAL #

PART NUMBER

 

 

Burner Orifice NG (#33DMS)

 

582-833

 

 

 

 

 

 

 

Burner Orifice LP (#51DMS)

 

582-851

 

 

 

 

 

 

 

Burner Orifice Butane (#53DMS)

 

582-853

 

 

 

 

 

1

 

Glass Door Assembly

 

GLA-6TROC

 

 

 

 

 

2

 

Burner Assembly (NG)

 

2068-011

 

 

 

 

 

2

 

Burner Assembly (LP & Butane)

 

2068-013

 

 

 

 

 

3

 

Log Grate

 

2068-020

 

 

 

 

 

4

 

Log Set Assembly (Sold as set only)

 

LOGS-ST-CE

 

 

 

 

 

5

 

Dress Guard Assembly

 

2068-040

 

 

 

 

 

6

 

Lower Door

 

2068-041

 

 

 

 

 

7

 

Side Refractory

 

SRV2005-730

 

 

 

 

 

 

 

Non-Combustible Board (Side)

 

2006-136

 

 

 

 

 

 

 

Door Stop

 

2068-144

 

 

 

 

 

 

 

Lava Rock Bag

 

2005-790

 

 

 

 

 

 

 

Junction Box

 

546-250A

 

 

 

 

 

 

 

Mesh Assembly, Small End

 

561-330A

 

 

 

 

 

 

 

Mesh Assembly

 

537-300

 

 

 

 

 

 

 

Fiber Glass Rope

 

060-455

 

 

 

 

 

 

 

Mineral Wool

 

050-721

 

 

 

 

 

 

 

Glass Latch Assembly

 

386-122A

 

 

 

 

 

 

 

Bracket, Junction Box

 

2068-106

 

 

 

 

 

 

ACCESSORIES

 

 

 

 

Hood, black

 

SRV2005-190

 

 

 

 

 

 

 

Hood End, black

 

SRV2006-194

 

 

 

 

 

 

 

Fan Kit

 

GFK-240V

 

 

 

 

 

 

 

Wall Thermostat Kit

 

MV-STAT

 

 

 

 

 

 

 

Wall Switch Kit, Off White

 

WSK-21

 

 

 

 

 

 

 

Wall Switch Kit, White

 

WSK-21-W

 

 

 

 

 

 

 

Conversion Kit, NG

 

NGK-ST-CE

 

 

 

 

 

 

 

Conversion Kit, LP

 

LPK-ST-CE

 

 

 

 

 

 

 

Conversion Kit, Butane

 

BGK-ST-CE

 

 

 

 

 

 

 

Regulator, NG

 

230-1570

 

 

 

 

 

 

 

Regulator, LP, Butane

 

230-4520

 

 

 

 

 

 

 

Pilot Orifice NG

 

529-512

 

 

 

 

 

 

 

Pilot Orifice LP

 

200-2630

 

 

 

 

 

Heat & Glo • PIER/ST/L&RCOR-HVB-CE2068-900 Rev. H • 6/07

7

Image 7
Contents 0087 Safety and Warning Information Table of Contents PIER-HVB-CE PIER-HVB-CE NG, LP Exploded Parts DiagramST-HVB-CE ST-HVB-CE LCOR-HVB-CE LCOR-HVB-CE RCOR-HVB-CE RCOR-HVB-CE RCOR-HVB-CE Í Valve AssemblyCertification Installation RegulationsPre-install Preparation Appliance CertificationHeat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Diagram of the PIER-HVB-CEDiagram of the ST-HVB-CE Diagram of the LCOR-HVB-CE and RCOR-HVB-CE Clearance Requirements Fireplace Dimensions and LocationsLocating the Fireplace Framing the FireplaceModel AT Each Joint Terminations Kits Installing the Flue SystemFlue System Approvals Identifying Flue ComponentsMax. Run Straight OUT HorizontalflueingFlueing with One 90 Elbow Flueing with Two 90 Elbows Propane / Butane Flueing with TWO 90 Elbows Flueing with three 90 elbows + H1 FT + V1 FT Attach the First Flue Component to the Starting Collars Installing Flue ComponentsContinue Adding Flue Components Install Support BracketsCombustibles inside the framed firestop opening Trapezoid Termination Cap Ceiling Firestop Ceiling SideMinimum Height from Roof to Lowest Discharge Opening Vent Termination Minimum Clearances Gas Control System Positioning, Leveling, and Securing the FireplaceSecuring of a Fireplace Gas Pressure Requirements Gas Supply LineNatural Gas Finishing Wiring the FireplaceOptional Accessories Wall SwitchAttachment of Lower Door Assembly Installing Trim, Logs & Ember MaterialLog placement Installing the TrimHeat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Only for Model LCOR-HVB-CE 3 4Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Heat & Glo PIER/ST/L&RCOR-HVB-CE 2068-900 Rev. H 6/07 Lighting the Fireplace After the InstallationDouble-check for faulty components Before Lighting the FireplaceChecking Flame Patterns, Flame Height Fireplace MaintenanceCleaning Glass Door Replacing old ember material5Troubleshooting Be Placed in this Opening Troubleshooting