Fostex CR300 ANALOG-SOURCE Recording, RW disc containing a Recordable space, To Analog

Page 22

ANALOG-SOURCE RECORDING

This function is for recording the analog output.

After loading the disc, check that the CD-R or CD-RW indicator stops blinking and starts to light steadily.

In case it does not light steadily, refer to page 42.

Track numbers are automatically up- dated when the AUTO TRACK indicator is on.

Track numbers are automatically up- dated if the following signal is input after 2-seconds of ”no signal” condition.

In the case of analog source, the CR300 detects the signal level selected by the ”Automatic Track Number Renewal Lev- el Sensitivity Setting” menu as ”no sig- nal”. Track numbers are automatically updated if the signal level exceeds this level. (See page 24.)

Therefore recordings of classical music and other music styles with long silent passages will be recorded on more tracks than required. Turn off the auto track function and create new tracks manually to avoid this problem.

Press the PAUSE ( ) or PLAY ( ) buttons after the counter displays "00:00".

1 3

2 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC

 

 

 

 

FADER

 

TRACK NO.

 

 

 

 

 

 

WREITE

 

 

 

 

REPEAT

 

 

 

5

6

 

 

 

 

 

 

 

1 Load a CD-R or CD-

 

 

 

 

 

 

Label side

 

 

 

 

 

 

 

 

RW disc containing a

 

 

 

 

 

 

 

 

recordable space.

 

 

 

 

 

 

 

 

For a disc loading, refer to

 

 

 

 

 

 

 

 

page 15.

 

 

 

 

 

 

 

2 Set the INPUT SELECTOR

 

INPUT SELECTOR

 

DIGITAL

 

XLR/+4

ANALOG

 

to ANALOG.

 

 

 

COAX

 

XLR/-10

 

 

 

 

 

 

 

 

OPT

 

 

LINE

 

Select the analog input to be recorded.

 

AESEBU/

 

 

 

 

XLR/+4 or XLR/-10 or LINE

 

 

 

 

 

 

 

3 Press the RECORD

 

 

 

 

 

 

 

 

(REC ) button(s).

 

 

 

 

 

 

 

 

• This unit enters record-pause mode.

 

 

 

 

 

 

Press two buttons

 

• Check the copy bit indicator

 

 

 

 

 

 

 

(refer to page 24).

 

 

 

 

 

 

together.

 

 

 

 

 

 

 

 

4

Adjust the recording level.

 

5

 

 

 

 

 

 

REC LEVEL

L

 

 

R

 

 

R e f e r t o p a g e 2 3 f o r t h e

4

 

 

6

7

 

 

adjustment method.

3

 

 

 

 

 

 

 

 

 

• Start playback of the

 

 

 

 

 

 

 

 

2

 

 

 

 

8

source player.

 

 

 

 

 

 

 

 

1

 

 

 

9

 

 

 

 

 

 

 

 

 

 

0

 

 

10

 

 

 

5 Press the pause ( )

or play ( ) button in

 

 

record-pause mode.

or

or

 

• This unit starts recording.

• Start playback of the source player after having started the recording of this unit.

6 After recording, press the stop ( ) button to end recording.

• "PMA REC" is displayed and the unit stops after recording the track data.

22

CR300 <PRB1291-A>

Image 22
Contents CR300 Safety Instructions For Canadian model Information to UserPour le modele Canadien Features Contents Battery loading method Checking AccessoriesAC power cord AAA/R03 dry cell batteries ... x Batteries AAA/R03 dry cell batteriesCD lens cleaner Precautions regarding installationCleaning the compact disc recorder LocationCD-R finalization DiscsDiscs usable with this unit CD-R and CD-RW discsDo not play a CD with a special shape Disc maintenanceHandling of disc Disc storageDigital Signal Connection ConnectionsAnalog Signal Connection Controls and Indicators Switching the time display Also be carried out by using buttons with the same Wireless remote controlParallel remote control Operations performed by buttons marked can2,4 Turn the power onDisc LOADING/UNLOADING Open the disc trayTrack numbers are updated automatically by this unit Mode of RecordingRecording a CD, DAT, MD or DCC source S/P DIF only Recording of other-than-audio signals Recording from the middle of a discTrack recording Load a CD-R or CD All-track recordingRW disc containing Recordable space Press the Finalize Automatic finalization recordingSynchro button twice ButtonPress the Record REC buttons Manual DIGITAL-SOURCE RecordingAfter recording, press the stop button to end recording ANALOG-SOURCE Recording Press the pause Or play button Record-pause modeAdjust the recording level RW disc containing a Recordable spaceLevel meter Recording level adjustmentAdjustment reference Minimum recording time per trackFade In / Fade Out Time Setting Copy Bit SettingAuto stop delay time Setting in Digital Synchro Menu Button FunctionsBalanced Output Level Setting Automatic Track Number Renewal Level Sensitivity SettingAuto Pause Mode Setting Sample Rate Converter ThruAutomatic writing of track number Track Number WritingManual writing of track number Press the Track no T O / M a N U a LCreating a blank Convenient Functions for RecordingTo pause recording Starting recording with fade-inChecking the recording end point from the middle of a disc Play the track to be skipped Setting skip ID to a track Track skipSkip ID Recording Press the Skip ID SET buttonClearing skip ID of a track Play the track which is not to be skippedRW disc which has Been recorded on What is finalization?Finalization TOC Recording Press the Finalize buttonErasing CD-RW only Erasing CD-RW discsLoad a CD-RW disc which has been finalized Load a CD-RW disc w h i c h h a s b e e n recorded onPress the Erase button Press the pause button to start the TOC erasingAll tracks erasing To pause playback PlaybackStarting playback Playing from the desired track Direct track selectionPress the track search Searching an adjacent track Track searchSearching the desired point Manual search Press and hold the manualPlaying tracks repeatedly Repeat playback Playback in Auto Pause ModePress the Repeat button of the remote control unit Fade-in/fade-out during playbackProgram reservation Programmed PlaybackPlaying Tracks in the Desired Order Programming pauseChecking the programmed tracks Clearing the entire programClearing a track from the program Replacing a track in the programPress the play button Load a disc containing the recording of skip ID dataCase skip playback is not required Character Message List Message Description Ref.Information messages related to recording operation Information messages related to playback operationSymptom Cause Remedy ConnectionsIndex Term Function Ref.Audio Unit typical Declaration of EC Directive Affect of Immunity on This EquipmentPage Fostex CO