Para asegurar su operacibn segura
315MHz Garage Door Opener
Contents
Tools needed
Preparing your garage door
Sectional Door Installations
Planning
Carton inventory
Safety Labels
IlililiIililitililil
Assembly Hardware
Assemble the Rail & Instaff the Troffey
Assembly Step t
Use ONLYthose boitstfastenersmountedin the top Opener
Assembly Step
Fasten the Rail to the Motor Unit
Atlach spreader to the motor unit with two screws
Trolley Be sure the chain is not twisted
Chain/Cable
1t2 38 cm high objector a 2x4 laid flat on the floor
Tighten the Chain
Determine the Header Bracket Location
Iinstallatioh Step
Mark the vertical set of bracket holes Drill 3/16
Install the Header Bracket
TiHSTALLAT!ION Step
Attach the Ra! to the Header Bracket
MNSTALLATmON Step
On E-PIECEDOOR with OUT Track
NNSTALLATHON Step
Position the Opener
Hang the Opener
Nstallation Step
Iil 11tH I Ifi Itili iiliTil
To opener terminal screws white to 2 white/red to
Rope and Handle
MNSTALLATilON Step
Do NOTuse bulbs largerthan 75W ONLYuseA19 sizebulbs
Attach the Emergency Release
ENectrical Requirements
NSTALLATmON Step
Unstallatoh Step
Install The Protector System
Installing the Brackets
Floor installation Figure
Mounting and Wiring the Safety Reversing Sensors
Aligning the Safety Reversing Sensors
Fasten the Door Bracket
NSTALLATmON Step t t
ONE-PIECE Doors
Screws not provided to fasten the bracket to the door
Hole alignment alternative
IHSTALLATllON Step
Connect the door arm to the trolley
Adjustment procedures, Figure
Assemble the door arm, Figure
HOW and When to Adjust the Limits
Adjustment Step t
Adjust the UP and Down Travel Limits
Test the UP open force
Adjustment Step
Adjust the Force
Test the Down close force
Test The Protector System s
Test the Safety Reversal System
Using Your Garage Door Opener
Important Safety ,NSTRUCTIONS
Lockout
Door Control
To Open the Door Manually
Care Your Garage Door Opener
Limit Force Forcecontrols Adjustments
Maintenance Schedule
Turning down limit adjustment screw clockwise
Refer to Adjustment , Adjust the Force
Symptom LED is not lit on door control
Diagnostic Chart
Function Remotes
To Add or Reprogram a Hand.held Remote Control
Programming
To Erase All Codes From Motor Unit Memory
To Add, Reprogram or Change a Keyless Entry PiN
To set a temporary PiN
183A163 Wear pads
Repair Parts
Installation Parts
Assembly & installation hardware bag see Ownersmanual
KEY Part
Motor Unit Assembly Parts
Drlva
For Sectional Doors Only
Warranty
Available only through Sears Parts & Service
Emergency Key Release
TNTRODUCCION
Contknido
Herramientas necesarias
PreparaciGn de la puerta de su cochera
Instalacion CON UNA Puerta Seccional
Pianificaci6n
Puerta DE UNA PtEZA CON Carril
Planificaci6n continUa
Instalacion CON Puertas DE UNA Sola Pieza
Puerta DE UNA Sola Pieza SIN Carril
Dosbl ndudores Dc4npanaBlar,coy. blanr.olroio
Nnventario de la Caja de CartOn
PemelocoI
TORNILLERtA Y Piezas Para EL Montaje
Monte el Riel e instale el Trole
MONTAJE, Paso
Estaspiezas SE Muestranen Sutamaio Real
Fije el Riel a la Unidad del Motor
Instale la Polea Loca
De pulg no ajuste demasiado la tuerce
#nstale ia Cadena y Cable
Paso
Eieroscado
INISTALACII6N
Extrema
INSTALACI6N, Paso t
Determine d6nde va a instalar ia Mnsula del Cabezal
Instalacion DE LA Mnsula DEL Cabezal EN EL Cielo Raso
Instale la Mnsula del Cabezal
Instalacon DE LA MleNSULA DEL Cabezal EN LA
Pared Delantera
16pot1q,2depulg
IINSTALACi6N, Paso
Coloque el Riel en la Mnsula dei Cabezal
Estas Piezasse Mliestranen Sutamanoreal
Puerta Seccional O Puerta DE UNA Sola Pieza CON Carril
Coloque el Abridor en Posici6n
Cueigue el Abridor
MNSTALACaON, Paso
Voltios
Lnstale la Unidad de Control de la Puerta
80TQN Decontroldelapuerta
Coloque la Manija y la Cuerda de EEmergencia
NSTALACaON, Paso
Hnstale ia Luz
Para evitar dificultades con la instalaci6n, no encienda
Bequisitos para la Instalaci6n ElcErica
Si la reglamentaci6n local exige que su abridor tenga
DE Seguridad
INSTALACmON, Paso t0
Nnstale La Sistema de Protecci6n
Informacin 1MPORTANTE CON Respects
InstalaciSn en el piss Figura
I71
Instalacion DE LAS Mensulas
Instalaci6n en la pared y
Si la luz indicadora del sensor que emile el rayo
LOS Sensores DEL Sistema DE Retroceso DE Seguridad
Puertas Seccionales
NNSTALACm6N, Paso
Fije la Mnsula de la Puerta
Puertas DE UNA Sola Pieza
Solo Para Puertas Seccionales
Conecte el Brazo de la Puerta al Trole
Ep.CLOl
5zo-8,na
Conecte el braze de la puerta al trole
Todas LAS Puertas DE UNA Sola Pieza
Arme el braze de la puerta, Figura
Interferencia visible en el ciclo def recorrido
Durante un ciclo complete del recorrido
COMa Y CU.,NDO Ajustar LOS LiMITES
Si la puerta retrocede cuando est# en la posiciSn
Eerrar
Ajuste la Fuerza
Como Y CU,NDO Ajustar LA Fuerza DEL Abridor
Ajuste
Pruebe el Sisterna de Retroceso de Seguridad
Pruebe La Sistema de Protecci6n e
Prueba
Seguridad de retroceso correctamente instalado y alineado
C6mo Usar su Abridor de Puerta de Cochera
Como Reconectar EL Trole
C6rno Usar la Unidad de Control de Pared
C6mo Abrir ia Puerta Manualmente
Como Desconectar EL Trole
Repita la prueba de retroceso de seguridad Ajustes
IANTSNIMgEHTO DE SU
Ajustes DE Limite Y Fuerza
Controlesde Limite
Consults el apartado Ajustes, Paso 2 Ajuste la fuerza
Sl Tiene ALGgN Problema
La puerta no cierra y las luces de la unidad del motor
E1 control remote no activa la puerta
Motor se calienta o hay un posible fallo de RPM
Tabla de Diagn6stico
Hay un cortocircuito en el cable de los sensores de
Los sensores de retroceso
COMa Usar EL Baton Learn Aprender
C6mo Agregar o Reprogramar un Control Remoto Manual
Controles Rernotos de 3 Funciones
Enter
Cierre con un bot6n
Mnsulas de extensi6n
Liberador de la Ilave de emergencia
Meinsulas de soporte
Consota de control premium
Call anytime, day or night USoA. only
LE-FOYER M
SU-HOGAR sM
Call anytime, day or night U SeA, and Canada