KitchenAid 9760425A Complete Chimney Support Installation, Make Electrical Connection

Page 8
Complete Chimney Support Installation

3.Attach the extension to the support using the 4 bolts supplied with the extension kit. Tighten bolts securely.

9.Replace the four screws and tighten securely.

A

D

C

B

A. Chimney extension frame

B. Chimney support

C.Bolt

D.Captive threaded insert

Complete Chimney Support Installation

1.Run wire through the 1¹⁄₄" (3.0 cm) electrical hole in the ceiling according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical wiring box.

2.Use caulk to seal all openings.

NOTE: Do not reconnect power until installation is complete.

3.Remove wiring box cover located on the top section of the chimney support.

4.Install a UL- or CSA-listed strain relief in the wiring box so that the screws can be tightened after the chimney support is attached to the ceiling.

5.Lift chimney support into final position, feeding electrical wire through the strain relief.

6.Position the chimney support so that the large end of the keyhole slots are over the ceiling attachment bolts. Then push the chimney support so that the bolts are in the neck of the slots. Tighten bolts securely.

IMPORTANT: The chimney support must be securely attached to the ceiling.

7.Determine the desired length of the chimney support.

8.Remove the four screws and adjust the length of the lower chimney support as needed.

NOTE: This is the only section that can be adjusted.

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Use twist-on connectors and connect black wires together.

3.Use twist-on connectors and connect white wires together.

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death or electrical shock.

4.Connect ground wire to green ground screw in terminal box.

A

B

 

C

 

 

 

A. Ground screw connector

 

 

 

 

B. Ground wire

 

 

 

 

C. Power supply cable

 

A

5.

Tighten strain relief securely.

 

6.

Replace wiring box cover. Tighten screw securely.

A. Screws

8

Image 8
Contents Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future referenceSave installation instructions for local inspectors use Installateur Remettre les instructions dinstallation au propriétaireTABLE OF CONTENTS RANGE HOOD SAFETYYour safety and the safety of others are very important INSTALLATION INSTRUCTIONSIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONSINSTALLATION REQUIREMENTS Product DimensionsRecirculating chimney kit dimensions Tools and PartsInstallation Clearances Cold weather installationsVenting Requirements Venting MethodsElectrical Shock Hazard Disconnect power before servicing Electrical RequirementsCalculating Vent System Length Replace all parts and panels before operatingINSTALLATION INSTRUCTIONS Install Chimney SupportInstalling Chimney Extension Kit Optional Excessive Weight HazardComplete Chimney Support Installation Connect ground wire to green ground screw in terminal boxMake Electrical Connection Electrical Shock Hazard Electrically ground blowerInstall Chimney Covers Vented Installation OptionRecirculating Installation Option, Kit Required Chimney Extension Kit Installation OptionalInstall Range Hood Complete InstallationRANGE HOOD USE OperationCheck Operation Hood control panelCleaning and Maintenance AccessoriesCharcoal Filters - For recirculating installations RANGE HOOD CAREREQUESTING ASSISTANCE OR SERVICE If you need assistance or service in U.S.AIf you need assistance or service in Canada If you need replacement partsOR CONSEQUENTIAL DAMAGES RANGE HOOD WARRANTYKitchenAid will not pay for WIRING DIAGRAM Votre sécurité et celle des autres est très importante SÉCURITÉ DE LA HOTTE DE CUISINIÈREDANGER AVERTISSEMENT IMPORTANTES INSTRUCTIONS DE SÉCURITÉ CONSERVEZ CES INSTRUCTIONSEXIGENCES DINSTALLATION Exigences demplacementDimensions du produit Kit de cheminée pour une installation avec recyclage - dimensionsInstallation dans une région à climat froid Exigences concernant lévacuationDégagements de séparation à respecter Méthodes dévacuationAVERTISSEMENT Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Risque de choc électriqueINSTRUCTIONS DINSTALLATION Installation du support de cheminéeInstallation de lextension de cheminée option Risque du poids excessifRaccordement électrique Achever linstallation du support de cheminéeOption de linstallation du cache-cheminée Installation avec décharge à lextérieurOption de linstallation avec recyclage, kit nécessaire Risque de choc électrique Relier le ventilateur à la terreInstallation de la hotte de cuisinière Installation du kit dextension de cheminée optionAchever linstallation Contrôle du fonctionnementTableau de commande de la hotte CUISINIÈREFonctionnement Nettoyage et entretienRemplacement dune lampe à halogène AccessoiresFiltres à charbon - Installation sans décharge à lextérieur recyclage DEMANDE DASSISTANCE OU DE SERVICE Si vous avez besoin dassistance ou de service aux États-UnisSi vous avez besoin dassistance ou de service au Canada Pour pièces, accessoires et service au CanadaDOMMAGES FORTUITS OU INDIRECTS GARANTIE DE LA HOTTE DE CUISINIÈREKitchenAid ne paiera pas pour SCHÉMA DE CÂBLAGE GRISVERT GROUPE MOTEUR LAMPE DIRECTIONNELLEPage 9760425A Printed in U.S.A2005, KitchenAid Imprimé aux É.-U