Emerson 3051N manual Review Configuration Data, Check Output, Process Variables

Page 19

Reference Manual

00809-0100-4808, Rev CA June 2008

Rosemount 3051N

REVIEW CONFIGURATION DATA

HART Comm

1, 5

 

 

CHECK OUTPUT

Process Variables

HART Comm.

2

 

 

NOTE

Information and procedures in this section that make use of HART Communicator fast key sequences assume that the transmitter and communicator are connected, powered, and operating correctly. If you are not familiar with the HART Communicator or fast-key sequences, refer to Appendix A: HART Communicator.

Before you place the transmitter into operation, it is recommended that you review the transmitter configuration data that was set at the factory. You should review the following configuration data:

Transmitter Model

Type

Tag

Range

Date

Descriptor

Message

Minimum and Maximum

 

Sensor Limits

Minimum Span

Units

4 and 20 mA points

Output (linear or sq. root)

Damping

Alarm Setting (high, low)

Security Setting (on, off)

Local Zero/Span Keys

 

(enabled, disabled)

Integral Meter

Sensor Fill

Isolator Material

Flange (type, material)

O-Ring Material

Drain/Vent

Remote Seal (type, fill fluid,

Transmitter S/N

isolator material, number)

 

Address

Sensor S/N

Before performing other transmitter on-line operations, review the digital output parameters to ensure that the transmitter is operating properly and is configured to the appropriate process variables.

The process variables for the Rosemount 3051N provide the transmitter output, and are continuously updated. The process variable menu displays the following process variables:

Pressure

Percent of Range

Analog Output

The pressure reading in both Engineering Units and Percent of Range will continue to track with pressures outside of the defined range from the lower to the upper range limit of the sensor module.

2-7

Image 19
Contents Reference Manual Important Notice -- Errata Rosemount 3051N Return of Material Old Changes from June 2006 to JuneChanges Rosemount 3051N Table of Contents Troubleshooting InstallationSpecifications Reference Data Appendix a OptionsHart Communicator Glossary Index Section Introduction Using this ManualRosemount 3051N Transmitter Functions Overview Safety MessagesTransmitter Alarm Level VerificationSecurity Physical Removal Local Zero and Span Local Keys Configuring Transmitter Alarm and Security Jumper ProcedureElectronics Board Setting the Loop to Manual Wiring Diagrams Bench Hook-up Wiring Diagrams Field Hook-up Check Output Review Configuration DataProcess Variables Set Output Sensor TemperatureBasic Setup Set Process Variable UnitsRerange with a Communicator Only RerangeRerange with a Pressure Input Source and a Communicator Span and Zero Adjustment Buttons Diagnostics Service Detailed SetupLoop Test Transmitter TestCalibration Transmitter Bench Calibration Tasks Field Calibration Tasks Calibration Overview Configure the Analog Output ParametersURV Sensor TrimTypical Zero vs Non-zero-Based Application Illustrations Zero TrimDigital Trim Connection Drawing 4-20 mA Transmitters Full TrimAnalog Output Trim Digital-to-Analog Trim Using Other ScaleRecall Factory Trim Recall Factory Trim- Sensor Trim Recall Factory Trim- Analog OutputZero Effect HTc = URV + S URV Ps Rosemount 3051N Section Installation Rosemount 3051N Typical Installation Flowchart Special Draft Range Considerations General ConsiderationsMechanical Considerations 156 181 16 x 11/4 Bolts for Mounting to 54.1 Transmitter 120 127 66.8 Traditional Flange Option Code H2 Dimensional Drawing Mounting Rosemount 3051N GAS or Liquid Service GAS Service Steam Service Power Supply Process Connections Housing RotationElectrical Considerations Power Supply Load Limitations WiringGrounding the Transmitter Case Access Requirements Cover InstallationEnvironmental Considerations Troubleshooting Returning Rosemount Products and Materials Symptom Corrective ActionsSeismic Nuclear SpecificationsModel Range Code Hydrostatic Test Pressure Drift Performance SpecificationsAmbient Temperature Effect12 Reference AccuracyRange Code Static Pressure Zero Effect1 Power Supply Effect Load Effect Mounting Position EffectOverpressure Effect Static Pressure Effect Range Code Overpressure EffectOutput Functional SpecificationsService Temperature LimitsRange Minimum Span Upper URL Lower LRL Span and Zero, Zero Elevation, SuppressionRange Code Minimum Time Constant Tc Including Dead Time Td Overpressure Limits Burst Pressure Maximum WorkingPressure12 Static Pressure LimitsPhysical Specifications Materials of Construction Option Code Description Add Ordering Information Meters optional Configuration InformationHousing Material Conduit Entry Size Mounting Bracket OptionsDate  On Rosemount 3051N Exploded View with Coplanar Process Flange Rosemount 3051N Rosemount 3051N Section Options Overview Safety Messages LCD MeterCustom Meter Configuration Exploded View of the Rosemount 3051N with Optional LCD Meter Installing the MeterRosemount 3051N Error Diagnostic MessagesPress Limit Mounting Brackets OperationTransient Protection Terminal Block T1 Traditional Flange H2Transient Protection Terminal Block T1 Rosemount 3051N Appendix a Hart Communicator Introduction Safety MessagesRosemount 3051N Online Menu Function Hart Fast Key Sequence Connections and Hardware Figure A-3. Rosemount Hart terminal access doorFigure A-4. Bench Hook-up MA Transmitters Communicator Keys RosemountAction Keys Alphanumeric and Shift Keys Function KeysData Entry Main Menu Fast Key SequencesFast Key Sequence Conventions Fast Key Sequence Example Menus FunctionsOnline Menu Touch Multifunction LED Processing Indication Alphanumeric KeysMultifunction LED Touch ScreenRosemount 3051N Fast Key Sequences Hot Key options Diagnostic MessagesMessage Description Rosemount 3051N Uploadvariable Rosemount 3051N Rosemount 3051N Glossary Smart Family Index 00809-0100-4808, Rev CA June Security Page ¢00809-0100-4801V¤