Emerson manual Rosemount 3051N

Page 78

Rosemount 3051N

Reference Manual

00809-0100-4808, Rev CA June 2008

Warnings

Explosions can result in death or serious injury.

Do not remove the transmitter covers in explosive environments when the circuit is alive.

Before connecting a communicator in an explosive atmosphere, make sure the instruments in the loop are installed according to intrinsically safe or nonincendive field wiring practices.

If you choose to ignore all field device status messages, every message from nuisance to critical will be ignored.

Voltage measurements are for reference purposes only. Do not make critical process control decisions based upon this voltage.

A-2

Image 78
Contents Reference Manual Important Notice -- Errata Rosemount 3051N Return of Material Changes from June 2006 to June OldChanges Rosemount 3051N Table of Contents Installation TroubleshootingSpecifications Reference Data Options Appendix aHart Communicator Glossary Index Using this Manual Section IntroductionRosemount 3051N Overview Safety Messages Transmitter FunctionsAlarm Level Verification TransmitterSecurity Configuring Transmitter Alarm and Security Jumper Procedure Physical Removal Local Zero and Span Local KeysElectronics Board Setting the Loop to Manual Wiring Diagrams Bench Hook-up Wiring Diagrams Field Hook-up Review Configuration Data Check OutputProcess Variables Set Process Variable Units Sensor TemperatureBasic Setup Set OutputRerange Rerange with a Communicator OnlyRerange with a Pressure Input Source and a Communicator Span and Zero Adjustment Buttons Detailed Setup Diagnostics ServiceTransmitter Test Loop TestCalibration Transmitter Bench Calibration Tasks Field Calibration Tasks Configure the Analog Output Parameters Calibration OverviewSensor Trim URVZero Trim Typical Zero vs Non-zero-Based Application IllustrationsFull Trim Digital Trim Connection Drawing 4-20 mA TransmittersRecall Factory Trim- Analog Output Digital-to-Analog Trim Using Other ScaleRecall Factory Trim Recall Factory Trim- Sensor Trim Analog Output TrimZero Effect HTc = URV + S URV Ps Rosemount 3051N Section Installation Rosemount 3051N Typical Installation Flowchart General Considerations Special Draft Range ConsiderationsMechanical Considerations 156 181 16 x 11/4 Bolts for Mounting to 54.1 Transmitter 120 127 66.8 Traditional Flange Option Code H2 Dimensional Drawing Mounting Rosemount 3051N GAS or Liquid Service GAS Service Steam Service Process Connections Housing Rotation Power SupplyElectrical Considerations Wiring Power Supply Load LimitationsAccess Requirements Cover Installation Grounding the Transmitter CaseEnvironmental Considerations Troubleshooting Symptom Corrective Actions Returning Rosemount Products and MaterialsNuclear Specifications SeismicModel Range Code Hydrostatic Test Pressure Reference Accuracy Performance SpecificationsAmbient Temperature Effect12 DriftRange Code Overpressure Effect Power Supply Effect Load Effect Mounting Position EffectOverpressure Effect Static Pressure Effect Range Code Static Pressure Zero Effect1Temperature Limits Functional SpecificationsService OutputSpan and Zero, Zero Elevation, Suppression Range Minimum Span Upper URL Lower LRLRange Code Minimum Time Constant Tc Including Dead Time Td Static Pressure Limits Maximum WorkingPressure12 Overpressure Limits Burst PressurePhysical Specifications Materials of Construction Option Code Description Add Ordering Information Mounting Bracket Options Configuration InformationHousing Material Conduit Entry Size Meters optionalDate  On Rosemount 3051N Exploded View with Coplanar Process Flange Rosemount 3051N Rosemount 3051N Overview Safety Messages LCD Meter Section OptionsCustom Meter Configuration Installing the Meter Exploded View of the Rosemount 3051N with Optional LCD MeterRosemount 3051N Diagnostic Messages ErrorPress Limit Operation Mounting BracketsTraditional Flange H2 Transient Protection Terminal Block T1Transient Protection Terminal Block T1 Rosemount 3051N Introduction Safety Messages Appendix a Hart CommunicatorRosemount 3051N Online Menu Function Hart Fast Key Sequence Figure A-3. Rosemount Hart terminal access door Connections and HardwareFigure A-4. Bench Hook-up MA Transmitters Rosemount Communicator KeysAction Keys Function Keys Alphanumeric and Shift KeysData Entry Menus Functions Fast Key SequencesFast Key Sequence Conventions Fast Key Sequence Example Main MenuOnline Menu Touch Touch Screen Alphanumeric KeysMultifunction LED Multifunction LED Processing IndicationRosemount 3051N Diagnostic Messages Fast Key Sequences Hot Key optionsMessage Description Rosemount 3051N Uploadvariable Rosemount 3051N Rosemount 3051N Glossary Smart Family Index 00809-0100-4808, Rev CA June Security Page ¢00809-0100-4801V¤