FIGURE 3-3. Rosemount 3051N Coplanar Flange Dimensional Drawing (Differential Pressure Transmitter Shown)

 

5 (127)

Meter

 

Cover

4.3 (110)

(optional)

 

0.75 (20)

Clearance

for Cover

Removal

Transmitter

circuitry

Nameplate

1/2-14 NPT Conduit Connection (two places)

0.75(20)

Clearance for Cover Removal

Terminal

Connections

Label

4.1 (105)

7.1

(181)

Drain/vent Valve

Housing Rotation Set Screw

6.4 (163)

Note

Dimensions are nominal in inches (millimeters).

1/4-18 NPT on Coplanar Flange for Pressure Connection

1/4-18 NPT on Coplanar Flange for Pressure Connection

3-6

Image 40
Contents Reference Manual Important Notice -- Errata Rosemount 3051N Return of Material Old Changes from June 2006 to JuneChanges Rosemount 3051N Table of Contents Troubleshooting InstallationSpecifications Reference Data Appendix a OptionsHart Communicator Glossary Index Using this Manual Section IntroductionRosemount 3051N Overview Safety Messages Transmitter FunctionsTransmitter Alarm Level VerificationSecurity Configuring Transmitter Alarm and Security Jumper Procedure Physical Removal Local Zero and Span Local KeysElectronics Board Setting the Loop to Manual Wiring Diagrams Bench Hook-up Wiring Diagrams Field Hook-up Check Output Review Configuration DataProcess Variables Sensor Temperature Basic SetupSet Process Variable Units Set OutputRerange Rerange with a Communicator OnlyRerange with a Pressure Input Source and a Communicator Span and Zero Adjustment Buttons Detailed Setup Diagnostics ServiceLoop Test Transmitter TestCalibration Transmitter Bench Calibration Tasks Field Calibration Tasks Configure the Analog Output Parameters Calibration OverviewSensor Trim URVZero Trim Typical Zero vs Non-zero-Based Application IllustrationsFull Trim Digital Trim Connection Drawing 4-20 mA TransmittersDigital-to-Analog Trim Using Other Scale Recall Factory Trim Recall Factory Trim- Sensor TrimRecall Factory Trim- Analog Output Analog Output TrimZero Effect HTc = URV + S URV Ps Rosemount 3051N Section Installation Rosemount 3051N Typical Installation Flowchart Special Draft Range Considerations General ConsiderationsMechanical Considerations 156 181 16 x 11/4 Bolts for Mounting to 54.1 Transmitter 120 127 66.8 Traditional Flange Option Code H2 Dimensional Drawing Mounting Rosemount 3051N GAS or Liquid Service GAS Service Steam Service Power Supply Process Connections Housing RotationElectrical Considerations Wiring Power Supply Load LimitationsGrounding the Transmitter Case Access Requirements Cover InstallationEnvironmental Considerations Troubleshooting Symptom Corrective Actions Returning Rosemount Products and MaterialsNuclear Specifications SeismicModel Range Code Hydrostatic Test Pressure Performance Specifications Ambient Temperature Effect12Reference Accuracy DriftPower Supply Effect Load Effect Mounting Position Effect Overpressure Effect Static Pressure EffectRange Code Overpressure Effect Range Code Static Pressure Zero Effect1Functional Specifications ServiceTemperature Limits OutputRange Minimum Span Upper URL Lower LRL Span and Zero, Zero Elevation, SuppressionRange Code Minimum Time Constant Tc Including Dead Time Td Maximum Working Pressure12Static Pressure Limits Overpressure Limits Burst PressurePhysical Specifications Materials of Construction Option Code Description Add Ordering Information Configuration Information Housing Material Conduit Entry SizeMounting Bracket Options Meters optionalDate  On Rosemount 3051N Exploded View with Coplanar Process Flange Rosemount 3051N Rosemount 3051N Overview Safety Messages LCD Meter Section OptionsCustom Meter Configuration Installing the Meter Exploded View of the Rosemount 3051N with Optional LCD MeterRosemount 3051N Diagnostic Messages ErrorPress Limit Operation Mounting BracketsTraditional Flange H2 Transient Protection Terminal Block T1Transient Protection Terminal Block T1 Rosemount 3051N Introduction Safety Messages Appendix a Hart CommunicatorRosemount 3051N Online Menu Function Hart Fast Key Sequence Figure A-3. Rosemount Hart terminal access door Connections and HardwareFigure A-4. Bench Hook-up MA Transmitters Communicator Keys RosemountAction Keys Alphanumeric and Shift Keys Function KeysData Entry Fast Key Sequences Fast Key Sequence Conventions Fast Key Sequence ExampleMenus Functions Main MenuOnline Menu Touch Alphanumeric Keys Multifunction LEDTouch Screen Multifunction LED Processing IndicationRosemount 3051N Fast Key Sequences Hot Key options Diagnostic MessagesMessage Description Rosemount 3051N Uploadvariable Rosemount 3051N Rosemount 3051N Glossary Smart Family Index 00809-0100-4808, Rev CA June Security Page ¢00809-0100-4801V¤