Emerson 3051N manual Ordering Information

Page 60

Rosemount 3051N

Reference Manual

00809-0100-4808, Rev CA June 2008

ORDERING

 

 

 

 

 

 

 

 

INFORMATION

 

 

(1)

 

 

 

 

 

 

 

 

Rosemount 3051N Differential, Gage, and Absolute Pressure Transmitters

 

 

 

 

 

 

 

— = Not Applicable • = Applicable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)

 

Rosemount

Transmitter Type (Select One)

 

 

 

 

ND

NG

NA

 

 

 

 

 

 

 

 

 

3051ND

Differential Pressure Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3051NG

Gage Pressure Transmitter

 

 

 

 

3051NA

Absolute Pressure Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Ranges (RANGE/MIN. SPAN)

 

 

 

 

 

 

Code

Rosemount 3051ND

 

Rosemount 3051NG

Rosemount 3051NA

ND

NG

NA

 

 

 

 

 

 

 

 

 

0(2)

–3 to 3 inH2O/0.1 inH2O

 

Not Applicable

 

0 to 5 psia/0.167 psia

 

(–747 to 747 Pa/25 Pa)

 

 

 

(0 to 259 mmHga/8,6 mmHga)

 

 

 

1

–25 to 25 inH2O/0.5 inH2O

Not Applicable

 

0 to 30 psia/0.3 psia

 

(–6,22 to 6,22 kPa/0,12 kPa)

 

 

(0 to 207 kPa/2,1 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

2

–250 to 250 inH2O/2.5 inH2O

–250 to 250 inH2O/2.5 inH2O

0 to 150 psia/1.5 psia

 

(–62,2 to 62,2 kPa/0,6 kPa)

(–62,2 to 62,2 kPa/0,6 kPa)

(0 to 1 034 kPa/10,34 kPa)

 

 

 

3

–1000 to 1000 inH2O/10 inH2O

–393 to 1000inH2O/10in H2O

0 to 800 psia/8 psia

 

(–248 to 248 kPa/2,5 kPa)

 

(–101 to 249 kPa/2,5 kPa)

(0 to 5 516 kPa/55,16 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

–300 to 300 psi/3 psi

 

–14.2 to 300 psi/3 psi

0 to 4000 psia/40 psia

 

(–2 070 to 2 070 kPa/20,7 kPa)

(–101 to 2 070 kPa/20,7 kPa)

(0 to 27 580 kPa/276 kPa)

 

 

 

5

–2000 to 2000 psi/20 psi

 

–14.2 to 2000 psig/20 psi

Not Applicable

 

(–13 800 to13 800 kPa/

 

(–101 to 13 800 kPa/138 kPa)

 

 

 

 

 

 

138 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Rosemount

3051NG lower range limit varies with

atmospheric pressure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

4–20 mA with Digital Signal Based on HART Protocol

 

 

 

Materials of Construction

 

 

 

 

 

 

 

 

Process

 

 

 

 

 

 

 

 

 

Code

Flange Type

 

Flange Material

Drain/Vent

 

 

ND

NG

NA

 

 

 

 

 

 

 

 

 

 

 

2

Coplanar

 

SST

 

SST

 

 

 

 

 

 

 

 

 

 

 

 

0

Alternate Flange – See Option Code H2

 

 

 

Code

Isolating Diaphragm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

316L SST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Process O-ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

Glass-filled TFE

 

 

 

 

 

B(3)

Ethylene Propylene (EPR)

 

 

 

 

Code

Fill Fluid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Silicone oil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5-10

Image 60
Contents Reference Manual Important Notice -- Errata Rosemount 3051N Return of Material Changes from June 2006 to June OldChanges Rosemount 3051N Table of Contents Installation TroubleshootingSpecifications Reference Data Options Appendix aHart Communicator Glossary Index Using this Manual Section IntroductionRosemount 3051N Overview Safety Messages Transmitter FunctionsAlarm Level Verification TransmitterSecurity Configuring Transmitter Alarm and Security Jumper Procedure Physical Removal Local Zero and Span Local KeysElectronics Board Setting the Loop to Manual Wiring Diagrams Bench Hook-up Wiring Diagrams Field Hook-up Review Configuration Data Check OutputProcess Variables Sensor Temperature Basic SetupSet Process Variable Units Set OutputRerange Rerange with a Communicator OnlyRerange with a Pressure Input Source and a Communicator Span and Zero Adjustment Buttons Detailed Setup Diagnostics ServiceTransmitter Test Loop TestCalibration Transmitter Bench Calibration Tasks Field Calibration Tasks Configure the Analog Output Parameters Calibration OverviewSensor Trim URVZero Trim Typical Zero vs Non-zero-Based Application IllustrationsFull Trim Digital Trim Connection Drawing 4-20 mA TransmittersDigital-to-Analog Trim Using Other Scale Recall Factory Trim Recall Factory Trim- Sensor TrimRecall Factory Trim- Analog Output Analog Output TrimZero Effect HTc = URV + S URV Ps Rosemount 3051N Section Installation Rosemount 3051N Typical Installation Flowchart General Considerations Special Draft Range ConsiderationsMechanical Considerations 156 181 16 x 11/4 Bolts for Mounting to 54.1 Transmitter 120 127 66.8 Traditional Flange Option Code H2 Dimensional Drawing Mounting Rosemount 3051N GAS or Liquid Service GAS Service Steam Service Process Connections Housing Rotation Power SupplyElectrical Considerations Wiring Power Supply Load LimitationsAccess Requirements Cover Installation Grounding the Transmitter CaseEnvironmental Considerations Troubleshooting Symptom Corrective Actions Returning Rosemount Products and MaterialsNuclear Specifications SeismicModel Range Code Hydrostatic Test Pressure Performance Specifications Ambient Temperature Effect12Reference Accuracy DriftPower Supply Effect Load Effect Mounting Position Effect Overpressure Effect Static Pressure EffectRange Code Overpressure Effect Range Code Static Pressure Zero Effect1Functional Specifications ServiceTemperature Limits OutputSpan and Zero, Zero Elevation, Suppression Range Minimum Span Upper URL Lower LRLRange Code Minimum Time Constant Tc Including Dead Time Td Maximum Working Pressure12Static Pressure Limits Overpressure Limits Burst PressurePhysical Specifications Materials of Construction Option Code Description Add Ordering Information Configuration Information Housing Material Conduit Entry SizeMounting Bracket Options Meters optionalDate  On Rosemount 3051N Exploded View with Coplanar Process Flange Rosemount 3051N Rosemount 3051N Overview Safety Messages LCD Meter Section OptionsCustom Meter Configuration Installing the Meter Exploded View of the Rosemount 3051N with Optional LCD MeterRosemount 3051N Diagnostic Messages ErrorPress Limit Operation Mounting BracketsTraditional Flange H2 Transient Protection Terminal Block T1Transient Protection Terminal Block T1 Rosemount 3051N Introduction Safety Messages Appendix a Hart CommunicatorRosemount 3051N Online Menu Function Hart Fast Key Sequence Figure A-3. Rosemount Hart terminal access door Connections and HardwareFigure A-4. Bench Hook-up MA Transmitters Rosemount Communicator KeysAction Keys Function Keys Alphanumeric and Shift KeysData Entry Fast Key Sequences Fast Key Sequence Conventions Fast Key Sequence ExampleMenus Functions Main MenuOnline Menu Touch Alphanumeric Keys Multifunction LEDTouch Screen Multifunction LED Processing IndicationRosemount 3051N Diagnostic Messages Fast Key Sequences Hot Key optionsMessage Description Rosemount 3051N Uploadvariable Rosemount 3051N Rosemount 3051N Glossary Smart Family Index 00809-0100-4808, Rev CA June Security Page ¢00809-0100-4801V¤