Emerson 3051N manual Fast Key Sequences, Fast Key Sequence Conventions Fast Key Sequence Example

Page 85

Reference Manual

00809-0100-4808, Rev CA June 2008

Rosemount 3051N

Fast Key Sequences

HART fast key sequences provide quick on-line access to most transmitter variables and functions. Instead of stepping your way through the menu structure using the action keys, you can press a HART fast key sequence to move from the ONLINE MENU to the desired variable or function. On-screen instructions guide you through the rest of the screens.

Fast Key Sequence Conventions

Fast Key Sequence Example

MENUS AND

FUNCTIONS

Main Menu

The fast key sequences for the Rosemount 275 use the following conventions for their identification:

1 through 9–Refer to the keys located directly below the dedicated keypad.

Left Arrow–Refers to the LEFT ARROW directional key.

HART fast key sequences are made up of the series of numbers corresponding to the individual options in each step of the menu structure. For example, from the ONLINE MENU you can change the date. Following the menu structure, press 1 to reach Device Setup, press 3 for Basic Setup, press 4 for Device Info, press 1 for Date. The corresponding HART fast key sequence is 1, 3, 4, 1.

HART fast keys are operational only from the ONLINE MENU. If you use them consistently, you will need to return to the ONLINE MENU

by pressing HOME (F3) when it is available. If you do not start at the ONLINE MENU, the HART fast key sequences will not function properly.

Use Table A-1,an alphabetical listing of most on-line functions, to find the corresponding HART fast key sequences. These codes are applicable only to Rosemount 3051N transmitters and the HART Communicator.

The HART Communicator is a menu driven system. Each screen provides a menu of options that can be selected as outlined above, or provides direction for input of data, warnings, messages, or other instructions.

When the HART Communicator is turned on, one of two menus will appear. If the HART Communicator is connected to an operating loop, the communicator will find the device and display the ONLINE MENU (see below). If it is not connected to a loop, the communicator will indicate that no device was found. When you press OK (F4), it will display the MAIN menu.

The MAIN menu provides the following options:

Offline–The Offline option provides access to offline configuration data and simulation functions.

Online–The Online option checks for a device and if it finds one, brings up the ONLINE MENU.

Transfer–The Transfer option provides access to options for transferring data either from the HART Communicator (memory) to the transmitter (device) or vice versa. Transfer is used to move off-line data from the HART Communicator to the transmitter, or to retrieve data from a transmitter for off-line revision.

A-9

Image 85
Contents Reference Manual Important Notice -- Errata Rosemount 3051N Return of Material Old Changes from June 2006 to JuneChanges Rosemount 3051N Table of Contents Troubleshooting InstallationSpecifications Reference Data Appendix a OptionsHart Communicator Glossary Index Section Introduction Using this ManualRosemount 3051N Transmitter Functions Overview Safety MessagesTransmitter Alarm Level VerificationSecurity Physical Removal Local Zero and Span Local Keys Configuring Transmitter Alarm and Security Jumper ProcedureElectronics Board Setting the Loop to Manual Wiring Diagrams Bench Hook-up Wiring Diagrams Field Hook-up Check Output Review Configuration DataProcess Variables Basic Setup Sensor TemperatureSet Process Variable Units Set OutputRerange with a Communicator Only RerangeRerange with a Pressure Input Source and a Communicator Span and Zero Adjustment Buttons Diagnostics Service Detailed SetupLoop Test Transmitter TestCalibration Transmitter Bench Calibration Tasks Field Calibration Tasks Calibration Overview Configure the Analog Output ParametersURV Sensor TrimTypical Zero vs Non-zero-Based Application Illustrations Zero TrimDigital Trim Connection Drawing 4-20 mA Transmitters Full TrimRecall Factory Trim Recall Factory Trim- Sensor Trim Digital-to-Analog Trim Using Other ScaleRecall Factory Trim- Analog Output Analog Output TrimZero Effect HTc = URV + S URV Ps Rosemount 3051N Section Installation Rosemount 3051N Typical Installation Flowchart Special Draft Range Considerations General ConsiderationsMechanical Considerations 156 181 16 x 11/4 Bolts for Mounting to 54.1 Transmitter 120 127 66.8 Traditional Flange Option Code H2 Dimensional Drawing Mounting Rosemount 3051N GAS or Liquid Service GAS Service Steam Service Power Supply Process Connections Housing RotationElectrical Considerations Power Supply Load Limitations WiringGrounding the Transmitter Case Access Requirements Cover InstallationEnvironmental Considerations Troubleshooting Returning Rosemount Products and Materials Symptom Corrective ActionsSeismic Nuclear SpecificationsModel Range Code Hydrostatic Test Pressure Ambient Temperature Effect12 Performance SpecificationsReference Accuracy DriftOverpressure Effect Static Pressure Effect Power Supply Effect Load Effect Mounting Position EffectRange Code Overpressure Effect Range Code Static Pressure Zero Effect1Service Functional SpecificationsTemperature Limits OutputRange Minimum Span Upper URL Lower LRL Span and Zero, Zero Elevation, SuppressionRange Code Minimum Time Constant Tc Including Dead Time Td Pressure12 Maximum WorkingStatic Pressure Limits Overpressure Limits Burst PressurePhysical Specifications Materials of Construction Option Code Description Add Ordering Information Housing Material Conduit Entry Size Configuration InformationMounting Bracket Options Meters optionalDate  On Rosemount 3051N Exploded View with Coplanar Process Flange Rosemount 3051N Rosemount 3051N Section Options Overview Safety Messages LCD MeterCustom Meter Configuration Exploded View of the Rosemount 3051N with Optional LCD Meter Installing the MeterRosemount 3051N Error Diagnostic MessagesPress Limit Mounting Brackets OperationTransient Protection Terminal Block T1 Traditional Flange H2Transient Protection Terminal Block T1 Rosemount 3051N Appendix a Hart Communicator Introduction Safety MessagesRosemount 3051N Online Menu Function Hart Fast Key Sequence Connections and Hardware Figure A-3. Rosemount Hart terminal access doorFigure A-4. Bench Hook-up MA Transmitters Communicator Keys RosemountAction Keys Alphanumeric and Shift Keys Function KeysData Entry Fast Key Sequence Conventions Fast Key Sequence Example Fast Key SequencesMenus Functions Main MenuOnline Menu Touch Multifunction LED Alphanumeric KeysTouch Screen Multifunction LED Processing IndicationRosemount 3051N Fast Key Sequences Hot Key options Diagnostic MessagesMessage Description Rosemount 3051N Uploadvariable Rosemount 3051N Rosemount 3051N Glossary Smart Family Index 00809-0100-4808, Rev CA June Security Page ¢00809-0100-4801V¤