DEAN MILLIVOLT GAS FRYERS
CHAPTER 2: IMPORTANT INFORMATION
2.2 General (cont.)
Dean Super Marathon Series gas fryers are energy efficient,
All units are shipped completely assembled with accessories packed inside the frypots. All units are adjusted, tested and inspected at the factory before shipment. Sizes, weights and input rates of all models are listed in this manual.
WARNING
The
the inherent dangers of operating a
2.3 Principles of Operation
The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slower and more turbulent flame gives much better heat transfer to the walls of the tubes, thereby heating the oil more efficiently.
2.4 Rating Plate
This is attached to the inside front door panel. Information provided includes the model and serial number of the fryer, BTU/hr input of the burners, outlet gas pressure in inches W.C. and whether the unit has natural or propane gas orifices.
DANGER
Fryers MUST be connected ONLY to the gas type identified on the attached rating
plate.