Frymaster SM35 operation manual Gas Inputs, Btu

Page 25

DEAN MILLIVOLT GAS FRYERS (NON-CE)

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.6 Gas Inputs

Nominal Heat Inputs (Qn), Gas Type, Orifice Size (applicable for fryer operation at altitudes of 2000 feet or less), Part Number and Quantity are listed in the table below:

MODEL

NOMINAL HEAT

GAS TYPE

ORIFICE SIZE

ORIFICE

ORIFICE

 

INPUT- Qn

 

(MM)

PART NO.

QUANTITY

 

(BTU)

 

 

 

 

SM 80 GM

165

NAT

2.58(#38)

810-2062

5

LP

1.61(#52)

810-2063

5

 

 

 

 

 

 

 

 

SM 60 GM

150

NAT

2.53(#39)

810-2048

5

LP

1.51(#53)

810-2059

5

SR 62G

 

LP

1.61(#52)**

810-2063**

5

 

 

 

 

 

 

 

 

SR 52 GM

120

NAT

2.53(#39)

810-2048

4

SM 50 GM

LP

1.51(#53)

810-2059

4

 

 

 

 

 

 

 

SM 35 GM

105

NAT

2.80(#35)

810-2040/*810-3097

3

SR 42G

LP

1.70(#51)

810-2064/*810-3099

3

 

 

 

 

 

 

 

SM 20 GM

50

NAT

2.18(#44)

810-2050

2

LP

1.40(#54)

810-2324

2

 

 

 

 

 

 

 

 

* Use these orifices on SR42 fryers built after 4/07. ** Use these orifices for Australian units.

A. Adjustments for different gases are as follows:

Gas Adjustments

Gas Type

Natural

LP

 

 

 

Gas Supply Pressure*

4" W.C. (10 mbars)

11" W.C. (27.5 mbars)

 

 

 

Orifice Diameter

See Table Above.

See Table Above.

 

 

 

Burner Marking

None

None

 

 

 

Pilot Marking

26N

16LP

 

 

 

Gas pressure at the regulator

4" W.C. (10 mbars)

11" W.C. (27.5 mbars)

[Inches W.C. (mbar)]*

 

 

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating.

3-9

Image 25
Contents 8195895 Page Page Table of Contents Preventative Maintenance This page Intentionally Left Blank After Purchase Service InformationOrdering Parts Service Personnel Safety InformationQualified and/or Authorized Operating Personnel Qualified Service Personnel Qualified Installation PersonnelThis page Intentionally Left Blank General Receiving and Unpacking EquipmentIf your equipment arrives damaged Rating Plate Principles of OperationPre-Installation ANSI/NFPA #70 Equipment Installed at High AltitudesAir Supply and Ventilation This page Intentionally Left Blank Leg and Caster Installation Installing the FryerGeneral Leveling the Fryer Leg and Rigid Caster InstallationLegs Only Rigid Casters OnlyFront ViewRear Side View Installing Optional Swivel CastersNational Code Requirements Gas ConnectionsRecommended Gas Supply Line Sizes Gas Types Number of Fryers Supply Line SpecificationsManual shut-off valve Rigid ConnectionsRegulating Gas Pressure Gas Connections GAS Supply for Which IT is not Configured Adjustments/Adaptation To Different GasesBTU Gas InputsON/PILOT/OFF Gas Conversion ProceduresNatural Gas to Propane Kit Propane To Natural Gas Kit Gas Conversion ComponentsElectrical Connections Initial Start-up Dean Millivolt Series GAS Fryers NON-CE Fryer OperationsDean Millivolt Series GAS Fryers NON-CE Fryer Operations Boil-Out Procedure Final Preparation Dean Millivolt Series GAS Fryers NON-CE Fryer Operations This page Intentionally Left Blank Weekly Periodic/ Annual Pilot Burner Malfunction Dean Millivolt Series GAS Fryers NON-CE TroubleshootingMain Burner Malfunctions Recommended Spare Parts Wiring DiagramsService Hotline