CF SERIES GAS FRYERS
CHAPTER 3: OPERATING INSTRUCTIONS
For units equipped with other than Thermostat Controls
Place the computer/controller ON/OFF switch in the ON position and set the controller to – or program the computer for – the desired cooking temperature, referred to as the setpoint. The
NOTE: In KFC
approved procedure.
3.2Boiling-Out the Frypot
To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Frymaster recommends boiling out the frypot each time the oil or shortening is changed.
branded locations.
DANGER
Never leave the fryer unattended during the
1.Before lighting the burner, close the fryer drain valve(s) and fill the frypot to the bottom OIL- LEVEL line with a mixture of cold water and automatic dishwashing detergent.
2.For units equipped with a Thermostat or Solid State (Analog) Controller:
Set the thermostat to the lowest setting. Turn the fryer on as described in Section 3.1. Allow the solution to come to a boil, and then turn the gas valve knob to PILOT. Allow the solution to set for 30 minutes. Turn the fryer back on and allow the solution to come to a boil. Turn gas valve knob to OFF and allow solution to set for 30 minutes. Proceed to Step #8, this section.
3.For units equipped with a Digital Controller, set the setpoint to 195°F (91°C).
4.For units equipped with a Basket Lift Timer, press the