Frymaster CF Series or the transfer is very, slow. cont, Power Shower is not, spraying properly

Page 46
or the transfer is very

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6.4 Troubleshooting the Built-In Filtration System (cont.)

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

B. Improperly installed or prepared

 

 

filter pan components.

B. Remove the oil from the filter pan

 

 

 

Test: Close the drain valve.

and replace the filter paper,

 

ensuring that the filter paper

 

Move the filter handle to the OFF

 

support screen is in place under

 

position, pull the filter pan (and

 

the paper.

 

Power Shower, if so equipped)

 

 

 

from the unit. Move the filter

If this does not correct the

 

handle to the ON position.

 

problem, the filter tube suction

 

 

Pump starts, but no

If a strong stream of air is being

tube is probably blocked. Remove

the blockage using a thin, flexible

transfer takes place

pumped out of the oil return port

wire. If unable to remove the

or the transfer is very

(or the Power Shower port), the

blockage, call FASC.

slow. (cont.)

problem is with the filter pan

 

 

components.

 

 

 

C. Verify that filter connection

 

 

O-rings are present and in good

 

C. Improperly installed or prepared

condition.

 

 

 

filter pan components.

Replace the filter paper, ensuring

 

 

that the filter paper support screen

 

 

is properly positioned under the

 

 

paper.

 

 

 

 

A. Plugged openings or solidified

 

 

shortening in the Power Shower.

A. Clean the Power Shower per

 

 

 

Test: Look for oil squirting out

instructions in Chapter 5 of this

 

manual.

 

around the Power Shower gasket.

 

 

Power Shower is not

If so, Power Shower is obstructed.

 

B. Missing/worn O-rings and gasket

B. Verify that O-rings and gasket are

spraying properly.

on Power Shower.

present and in good condition.

 

C. Missing paper in filter pan. (This

 

 

causes too much pressure in the

 

 

oil return lines, resulting in a

C. Verify that filter paper is properly

 

strong flow through the Power

installed in the filter pan.

 

Shower, but also squirting of oil

 

 

from around the gasket.)

 

6-6

Image 46
Contents Gas Fryers Installation andCF Series APRILREQUIREMENTS in Chapter 2 of this manual for specifics Page CHAPTER 5 Preventive Maintenance TABLE OF CONTENTSCHAPTER 2 Installation Instructions CHAPTER 6 Operator TroubleshootingCF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION 1.2 Parts Ordering and Service Information1.1 Applicability and Validity CE Standard for Incoming Gas Pressures 1.3 Safety Information1.4 European Community CE Specific Information CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.5 Equipment Description Warranty on your equipment 1.6 Installation, Operating, and Service Personnel1.7 Definitions 1.8 Shipping Damage Claim Procedure CF SERIES GAS FRYERS CHAPTER 2 INSTALLATION INSTRUCTIONS 2.1 General Installation RequirementsThe fryers must be installed with a 6 150 mm clearance at both sides and back when installed adjacent to combustible construction no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 600 mm clearance should be provided at the front of the fryer The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped NAT only to natural gas, those stamped PRO only to propane gas, and those stamped MFG only to manufactured gas 2.2 Caster/Leg Installation 2.3 Pre-Connection Preparations4. Test the fryer electrical system 2.4 Connection to Gas Line CE Standard 2.5 Converting to Another Gas Type Non-CE Gas Conversion Instructions CE Gas Conversion InstructionsCE Only 2-10Non-CE Only Non-CE Gas Valve 3.1 Start-Up ProcedureCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS CE Gas ValveLIGHTING THE PILOT ON NON-CE FRYERS ACCESSING THE PILOTCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS least five minutes before attempting to re-light1. Ensure power to the unit is OFF, and then press the OFF red button. Wait 5 minutes 3.2 Boiling-Out the Frypot branded locations5. For units equipped with a Computer Magic III.5 Computer 3.3 Shutting the Fryer Down 3.4 Controller Operation and ProgrammingCF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS 4.1 Draining and Manual FilteringIf you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container 4.2 Filter Magic II Filtration System Operation 4.2 Filter Magic II Filtration System Operation cont 7. Replace the crumb tray in the filter pan 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF. Then open the drain valve on the fryer you have selected to be filtered. If necessary, use the Fryer’s Friend steel rod to clear the drain from inside the frypot as necessary CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS DANGER of the fryer and may cause injuryDrain handle in the closed position Inspect Fryer and Accessories for Damage CF SERIES GAS FRYERS CHAPTER 5 PREVENTATIVE MAINTENANCE5.1 Fryer Preventive Maintenance Checks and Services Clean Fryer Cabinet Inside and OutClean Float Switch and Shaft Check Recovery TimeDrain and Clean Frypot Clean Detachable Parts and Accessories Check Thermostat Controller Thermostat Calibration Clean Gas Valve Vent TubeCheck Computer Magic III Set Point Accuracy Check Burner Manifold Pressure 5.3 Annual/Periodic System Inspection FryerBuilt-In Filtration System CF SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTING 6.1 Introductionlight controller power andBurner will not Solid state analogmode. cont indicator does notindicator is on but CM III.5 displaysBurner does not 6.3 Troubleshooting Fryers with Thermostat Controls6.4 Troubleshooting the Built-In Filtration System Unit will not go intoPump starts, but no 6.4 Troubleshooting the Built-In Filtration System contfiltering. cont transfer takes placeslow. cont Power Shower is notor the transfer is very spraying properlyabove flue opening 6.5 Troubleshooting Abnormal Burner OperationFlame is visible and burner is6.6 Replacing the Controller or Controller Wiring Harness THIS PAGE INTENTIONALLY LEFT BLANK FAX Parts 1-318-219-7140 FAX Tech Support SERVICE HOTLINEShipping Address 8700 Line Avenue, Shreveport, Louisiana Price $12.00