Frymaster CF Series operation manual Cf Series Gas Fryers Introduction, Applicability and Validity

Page 5
CF SERIES GAS FRYERS

CF SERIES GAS FRYERS

CHAPTER 1: INTRODUCTION

1.1 Applicability and Validity

The CF Series Gas Fryer model family has been approved by the European Union for sale and installation in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE.

This manual is applicable to and valid for all CF Series Gas Fryer units sold in English- speaking countries, including those in the European Union. Where conflicts exist between instructions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes.

This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.7.

1.2 Parts Ordering and Service Information

In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door.

Parts orders must be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711.

When ordering parts, the following information is required:

Model Number:

Serial Number:

Type of Gas or Voltage:

Item Part Number:

Quantity Needed:

Service information may be obtained by contacting your local FASC. Information may also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865- 1711.

When requesting service, please have the following information ready:

Model Number:

Serial Number:

Type of Gas:

In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.

1-1

Image 5
Contents CF Series Installation andGas Fryers APRILREQUIREMENTS in Chapter 2 of this manual for specifics Page CHAPTER 2 Installation Instructions TABLE OF CONTENTSCHAPTER 5 Preventive Maintenance CHAPTER 6 Operator Troubleshooting1.1 Applicability and Validity 1.2 Parts Ordering and Service InformationCF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION 1.4 European Community CE Specific Information 1.3 Safety InformationCE Standard for Incoming Gas Pressures CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.5 Equipment Description 1.7 Definitions 1.6 Installation, Operating, and Service PersonnelWarranty on your equipment 1.8 Shipping Damage Claim Procedure 2.1 General Installation Requirements CF SERIES GAS FRYERS CHAPTER 2 INSTALLATION INSTRUCTIONSThe fryers must be installed with a 6 150 mm clearance at both sides and back when installed adjacent to combustible construction no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 600 mm clearance should be provided at the front of the fryer The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped NAT only to natural gas, those stamped PRO only to propane gas, and those stamped MFG only to manufactured gas 2.3 Pre-Connection Preparations 2.2 Caster/Leg Installation4. Test the fryer electrical system 2.4 Connection to Gas Line CE Standard 2.5 Converting to Another Gas Type CE Gas Conversion Instructions Non-CE Gas Conversion InstructionsNon-CE Only 2-10CE Only CF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS 3.1 Start-Up ProcedureNon-CE Gas Valve CE Gas ValveCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS ACCESSING THE PILOTLIGHTING THE PILOT ON NON-CE FRYERS least five minutes before attempting to re-light1. Ensure power to the unit is OFF, and then press the OFF red button. Wait 5 minutes branded locations 3.2 Boiling-Out the Frypot5. For units equipped with a Computer Magic III.5 Computer 3.4 Controller Operation and Programming 3.3 Shutting the Fryer Down4.1 Draining and Manual Filtering CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONSIf you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container 4.2 Filter Magic II Filtration System Operation 4.2 Filter Magic II Filtration System Operation cont 7. Replace the crumb tray in the filter pan 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF. Then open the drain valve on the fryer you have selected to be filtered. If necessary, use the Fryer’s Friend steel rod to clear the drain from inside the frypot as necessary of the fryer and may cause injury CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS DANGERDrain handle in the closed position 5.1 Fryer Preventive Maintenance Checks and Services CF SERIES GAS FRYERS CHAPTER 5 PREVENTATIVE MAINTENANCEInspect Fryer and Accessories for Damage Clean Fryer Cabinet Inside and OutDrain and Clean Frypot Check Recovery TimeClean Float Switch and Shaft Clean Detachable Parts and Accessories Check Computer Magic III Set Point Accuracy Clean Gas Valve Vent TubeCheck Thermostat Controller Thermostat Calibration Check Burner Manifold Pressure Fryer 5.3 Annual/Periodic System InspectionBuilt-In Filtration System 6.1 Introduction CF SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTINGBurner will not controller power andlight Solid state analogindicator is on but indicator does notmode. cont CM III.5 displays6.4 Troubleshooting the Built-In Filtration System 6.3 Troubleshooting Fryers with Thermostat ControlsBurner does not Unit will not go intofiltering. cont 6.4 Troubleshooting the Built-In Filtration System contPump starts, but no transfer takes placeor the transfer is very Power Shower is notslow. cont spraying properlyFlame is visible 6.5 Troubleshooting Abnormal Burner Operationabove flue opening and burner is6.6 Replacing the Controller or Controller Wiring Harness THIS PAGE INTENTIONALLY LEFT BLANK Shipping Address 8700 Line Avenue, Shreveport, Louisiana SERVICE HOTLINEFAX Parts 1-318-219-7140 FAX Tech Support Price $12.00