Frymaster CF Series Troubleshooting the Built-In Filtration System cont, filtering. cont

Page 45
6.4 Troubleshooting the Built-In Filtration System (cont.)

CF SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6.4 Troubleshooting the Built-In Filtration System (cont.)

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

B. Failed filter handle microswitch.

 

 

Test: If this is a multi-pot fryer,

B. If the switch is loose, tighten the

 

attempt to operate the pump using

 

a different handle. If the pump

screws holding it in place,

 

ensuring that when the handle is

 

starts, the handle microswitch is

 

placed in the ON position, the

 

out of alignment or has failed.

 

lever on the microswitch is

 

 

 

When the handle is placed in the

pressed firmly against the switch.

 

 

Pump won’t start.

ON position, the lever on the

If the switch has failed, call

microswitch should be firmly

FASC.

 

pressed against the switch. If so,

OR

 

the switch has failed. If not, the

 

Pump stops during

switch is loose and/or misaligned.

 

C. Pump blockage.

C. Pump blockages are usually

filtering. (cont.)

caused by sediment build-up in

 

Test: Close the drain valve. Place

the pump due to improperly sized

 

or installed filter paper and

 

the filter handle in the OFF

 

failure to use the crumb screen.

 

position, allow the pump to cool

 

Call FASC to have blockage

 

for at least 45 minutes, and then

 

cleared.

 

press the reset button on the pump

 

 

 

motor. Pull the filter pan from the

Ensure that filter paper is of the

 

unit and then activate the pump.

 

proper size and is installed

 

If the pump motor hums and then

 

properly, and that the crumb

 

stops, the pump is blocked.

 

screen is used.

 

 

 

 

A. To properly filter, the oil should

 

 

be at or near 350°F (177°C). At

 

 

temperatures lower than this, the

Pump starts, but no

 

oil becomes too thick to pass

 

through the filter medium easily,

transfer takes place

A. Oil/shortening is too cold for

resulting in much slower oil

or the transfer is

filtering.

return and eventual overheating of

very slow.

 

 

the filter pump motor. Ensure

 

 

 

 

that the oil is at or near frying

 

 

temperature before draining into

 

 

filter pan.

6-5

Image 45
Contents CF Series Installation andGas Fryers APRILREQUIREMENTS in Chapter 2 of this manual for specifics Page CHAPTER 2 Installation Instructions TABLE OF CONTENTSCHAPTER 5 Preventive Maintenance CHAPTER 6 Operator Troubleshooting1.2 Parts Ordering and Service Information CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.1 Applicability and Validity 1.4 European Community CE Specific Information 1.3 Safety InformationCE Standard for Incoming Gas Pressures CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.5 Equipment Description 1.6 Installation, Operating, and Service Personnel Warranty on your equipment1.7 Definitions 1.8 Shipping Damage Claim Procedure 2.1 General Installation Requirements CF SERIES GAS FRYERS CHAPTER 2 INSTALLATION INSTRUCTIONSThe fryers must be installed with a 6 150 mm clearance at both sides and back when installed adjacent to combustible construction no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 600 mm clearance should be provided at the front of the fryer The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped NAT only to natural gas, those stamped PRO only to propane gas, and those stamped MFG only to manufactured gas 2.3 Pre-Connection Preparations 2.2 Caster/Leg Installation4. Test the fryer electrical system 2.4 Connection to Gas Line CE Standard 2.5 Converting to Another Gas Type CE Gas Conversion Instructions Non-CE Gas Conversion Instructions2-10 CE OnlyNon-CE Only CF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS 3.1 Start-Up ProcedureNon-CE Gas Valve CE Gas ValveCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS ACCESSING THE PILOTLIGHTING THE PILOT ON NON-CE FRYERS least five minutes before attempting to re-light1. Ensure power to the unit is OFF, and then press the OFF red button. Wait 5 minutes branded locations 3.2 Boiling-Out the Frypot5. For units equipped with a Computer Magic III.5 Computer 3.4 Controller Operation and Programming 3.3 Shutting the Fryer Down4.1 Draining and Manual Filtering CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONSIf you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container 4.2 Filter Magic II Filtration System Operation 4.2 Filter Magic II Filtration System Operation cont 7. Replace the crumb tray in the filter pan 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF. Then open the drain valve on the fryer you have selected to be filtered. If necessary, use the Fryer’s Friend steel rod to clear the drain from inside the frypot as necessary of the fryer and may cause injury CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS DANGERDrain handle in the closed position 5.1 Fryer Preventive Maintenance Checks and Services CF SERIES GAS FRYERS CHAPTER 5 PREVENTATIVE MAINTENANCEInspect Fryer and Accessories for Damage Clean Fryer Cabinet Inside and OutCheck Recovery Time Clean Float Switch and ShaftDrain and Clean Frypot Clean Detachable Parts and Accessories Clean Gas Valve Vent Tube Check Thermostat Controller Thermostat CalibrationCheck Computer Magic III Set Point Accuracy Check Burner Manifold Pressure Fryer 5.3 Annual/Periodic System InspectionBuilt-In Filtration System 6.1 Introduction CF SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTINGBurner will not controller power andlight Solid state analogindicator is on but indicator does notmode. cont CM III.5 displays6.4 Troubleshooting the Built-In Filtration System 6.3 Troubleshooting Fryers with Thermostat ControlsBurner does not Unit will not go intofiltering. cont 6.4 Troubleshooting the Built-In Filtration System contPump starts, but no transfer takes placeor the transfer is very Power Shower is notslow. cont spraying properlyFlame is visible 6.5 Troubleshooting Abnormal Burner Operationabove flue opening and burner is6.6 Replacing the Controller or Controller Wiring Harness THIS PAGE INTENTIONALLY LEFT BLANK Shipping Address 8700 Line Avenue, Shreveport, Louisiana SERVICE HOTLINEFAX Parts 1-318-219-7140 FAX Tech Support Price $12.00