Frymaster CF Series operation manual

Page 27
If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.

CF SERIES GAS FRYERS

CHAPTER 4: FILTRATION INSTRUCTIONS

If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container.

3.Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

Manual background DANGER

DO NOT insert anything into the drain from the front to unclog the valve. Hot oil will

rush out, creating an extreme hazard.

Manual background WARNING

DO NOT hammer on the drain valve with the Fryer’s Friend. This will damage the drain valve ball and prevent the valve from sealing securely, resulting in a leaky valve.

4.After draining the oil, clean all food particles and residual oil from the frypot. If the fryer is equipped with a float switch, clean it at this time. The float switch prevents frypot damage in the event the power switch is not OFF while draining used oil. The float switch must be cleaned on a regular basis to ensure proper operation. Use caution as frypot residue can cause severe burns if it contacts bare skin.

5.Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil or solid shortening to the bottom OIL-LEVELline.

Manual background DANGER

When using solid shortening, pack it down into the cool-zone and the bottom of the frypot. DO NOT operate the fryer with a block of shortening sitting in the upper portion of the frypot. Irreparable damage to the frypot and a potential flash fire will result.

4-2

Image 27
Contents APRIL Installation andCF Series Gas FryersREQUIREMENTS in Chapter 2 of this manual for specifics Page CHAPTER 6 Operator Troubleshooting TABLE OF CONTENTSCHAPTER 2 Installation Instructions CHAPTER 5 Preventive Maintenance1.2 Parts Ordering and Service Information CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.1 Applicability and Validity CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION 1.3 Safety Information1.4 European Community CE Specific Information CE Standard for Incoming Gas Pressures1.5 Equipment Description 1.6 Installation, Operating, and Service Personnel Warranty on your equipment1.7 Definitions 1.8 Shipping Damage Claim Procedure 2.1 General Installation Requirements CF SERIES GAS FRYERS CHAPTER 2 INSTALLATION INSTRUCTIONSThe fryers must be installed with a 6 150 mm clearance at both sides and back when installed adjacent to combustible construction no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 600 mm clearance should be provided at the front of the fryer The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped NAT only to natural gas, those stamped PRO only to propane gas, and those stamped MFG only to manufactured gas 2.3 Pre-Connection Preparations 2.2 Caster/Leg Installation4. Test the fryer electrical system 2.4 Connection to Gas Line CE Standard 2.5 Converting to Another Gas Type CE Gas Conversion Instructions Non-CE Gas Conversion Instructions2-10 CE OnlyNon-CE Only CE Gas Valve 3.1 Start-Up ProcedureCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS Non-CE Gas Valveleast five minutes before attempting to re-light ACCESSING THE PILOTCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS LIGHTING THE PILOT ON NON-CE FRYERS1. Ensure power to the unit is OFF, and then press the OFF red button. Wait 5 minutes branded locations 3.2 Boiling-Out the Frypot5. For units equipped with a Computer Magic III.5 Computer 3.4 Controller Operation and Programming 3.3 Shutting the Fryer Down4.1 Draining and Manual Filtering CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONSIf you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container 4.2 Filter Magic II Filtration System Operation 4.2 Filter Magic II Filtration System Operation cont 7. Replace the crumb tray in the filter pan 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF. Then open the drain valve on the fryer you have selected to be filtered. If necessary, use the Fryer’s Friend steel rod to clear the drain from inside the frypot as necessary of the fryer and may cause injury CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS DANGERDrain handle in the closed position Clean Fryer Cabinet Inside and Out CF SERIES GAS FRYERS CHAPTER 5 PREVENTATIVE MAINTENANCE5.1 Fryer Preventive Maintenance Checks and Services Inspect Fryer and Accessories for DamageCheck Recovery Time Clean Float Switch and ShaftDrain and Clean Frypot Clean Detachable Parts and Accessories Clean Gas Valve Vent Tube Check Thermostat Controller Thermostat CalibrationCheck Computer Magic III Set Point Accuracy Check Burner Manifold Pressure Fryer 5.3 Annual/Periodic System InspectionBuilt-In Filtration System 6.1 Introduction CF SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTINGSolid state analog controller power andBurner will not lightCM III.5 displays indicator does notindicator is on but mode. contUnit will not go into 6.3 Troubleshooting Fryers with Thermostat Controls6.4 Troubleshooting the Built-In Filtration System Burner does nottransfer takes place 6.4 Troubleshooting the Built-In Filtration System contfiltering. cont Pump starts, but nospraying properly Power Shower is notor the transfer is very slow. contand burner is 6.5 Troubleshooting Abnormal Burner OperationFlame is visible above flue opening6.6 Replacing the Controller or Controller Wiring Harness THIS PAGE INTENTIONALLY LEFT BLANK Price $12.00 SERVICE HOTLINEShipping Address 8700 Line Avenue, Shreveport, Louisiana FAX Parts 1-318-219-7140 FAX Tech Support