1.Ensure frypot is filled with cooking oil or shortening.

2.Set the temperature control knob to 325°F (162°C) and insert a good grade thermometer or pyrometer into the frypot so that it touches the temperature probe guard.

3.When the burner cycles off, set the temperature control knob to 340°F (170°C). As the reading on the thermometer or pyrometer nears the control knob setting, but before the burner cycles off, reset the knob to 325°F (162°C). Just as the reading on the thermometer or pyrometer drops below 325°F (162°C), the burner should cycle on. If it does not, calibration is required. Contact a Factory Authorized Service Center (FASC) for service.

Check Computer Magic III Set Point Accuracy

(NOTE: This check applies only to units equipped with Computer Magic III.5 Controllers.)

1.Insert a good-grade thermometer or pyrometer into the oil, with the end touching the fryer temperature probe.

2.When the computer displays Check Computer Magic III Set Point Accuracywith no red dot between the first and second dashes

(indicating that the frypot contents are within the cooking range), press the Clean Gas Valve Vent Tube switch once to display the temperature of the cooking oil or shortening as sensed by the temperature probe.

3.Press the Manual background switch twice to display the set point.

4.Note the temperature on the thermometer or pyrometer. All three readings should be within ±5°F (2°C) of each other. If not, contact a Factory Authorized Service Center for assistance.

Clean Gas Valve Vent Tube

1.Carefully unscrew the vent tube from the valve. (NOTE: The vent tube may be straightened.)

2.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.

3.Remove the wire and blow through the tube to ensure it is clear.

4.Reinstall tube and bend it so that the opening is pointing downward.

5-4

Image 37
Contents CF Series Installation andGas Fryers APRILREQUIREMENTS in Chapter 2 of this manual for specifics Page CHAPTER 2 Installation Instructions TABLE OF CONTENTSCHAPTER 5 Preventive Maintenance CHAPTER 6 Operator TroubleshootingCF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION 1.2 Parts Ordering and Service Information1.1 Applicability and Validity 1.4 European Community CE Specific Information 1.3 Safety InformationCE Standard for Incoming Gas Pressures CF SERIES GAS FRYERS CHAPTER 1 INTRODUCTION1.5 Equipment Description Warranty on your equipment 1.6 Installation, Operating, and Service Personnel1.7 Definitions 1.8 Shipping Damage Claim Procedure 2.1 General Installation Requirements CF SERIES GAS FRYERS CHAPTER 2 INSTALLATION INSTRUCTIONSThe fryers must be installed with a 6 150 mm clearance at both sides and back when installed adjacent to combustible construction no clearance is required when installed adjacent to noncombustible construction. A minimum of 24 600 mm clearance should be provided at the front of the fryer The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped NAT only to natural gas, those stamped PRO only to propane gas, and those stamped MFG only to manufactured gas 2.3 Pre-Connection Preparations 2.2 Caster/Leg Installation4. Test the fryer electrical system 2.4 Connection to Gas Line CE Standard 2.5 Converting to Another Gas Type CE Gas Conversion Instructions Non-CE Gas Conversion InstructionsCE Only 2-10Non-CE Only CF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS 3.1 Start-Up ProcedureNon-CE Gas Valve CE Gas ValveCF SERIES GAS FRYERS CHAPTER 3 OPERATING INSTRUCTIONS ACCESSING THE PILOTLIGHTING THE PILOT ON NON-CE FRYERS least five minutes before attempting to re-light1. Ensure power to the unit is OFF, and then press the OFF red button. Wait 5 minutes branded locations 3.2 Boiling-Out the Frypot5. For units equipped with a Computer Magic III.5 Computer 3.4 Controller Operation and Programming 3.3 Shutting the Fryer Down4.1 Draining and Manual Filtering CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONSIf you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container 4.2 Filter Magic II Filtration System Operation 4.2 Filter Magic II Filtration System Operation cont 7. Replace the crumb tray in the filter pan 1. To filter the oil, bring oil to operating temperature and turn the fryer power OFF. Then open the drain valve on the fryer you have selected to be filtered. If necessary, use the Fryer’s Friend steel rod to clear the drain from inside the frypot as necessary of the fryer and may cause injury CF SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS DANGERDrain handle in the closed position 5.1 Fryer Preventive Maintenance Checks and Services CF SERIES GAS FRYERS CHAPTER 5 PREVENTATIVE MAINTENANCEInspect Fryer and Accessories for Damage Clean Fryer Cabinet Inside and OutClean Float Switch and Shaft Check Recovery TimeDrain and Clean Frypot Clean Detachable Parts and Accessories Check Thermostat Controller Thermostat Calibration Clean Gas Valve Vent TubeCheck Computer Magic III Set Point Accuracy Check Burner Manifold Pressure Fryer 5.3 Annual/Periodic System InspectionBuilt-In Filtration System 6.1 Introduction CF SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTINGBurner will not controller power andlight Solid state analogindicator is on but indicator does notmode. cont CM III.5 displays6.4 Troubleshooting the Built-In Filtration System 6.3 Troubleshooting Fryers with Thermostat ControlsBurner does not Unit will not go intofiltering. cont 6.4 Troubleshooting the Built-In Filtration System contPump starts, but no transfer takes placeor the transfer is very Power Shower is notslow. cont spraying properlyFlame is visible 6.5 Troubleshooting Abnormal Burner Operationabove flue opening and burner is6.6 Replacing the Controller or Controller Wiring Harness THIS PAGE INTENTIONALLY LEFT BLANK Shipping Address 8700 Line Avenue, Shreveport, Louisiana SERVICE HOTLINEFAX Parts 1-318-219-7140 FAX Tech Support Price $12.00