Jenn-Air W10282143B manual Connect Water Supply, Connecting the Water Line, Rear View

Page 7

Connect Water Supply

Read all directions before you begin.

IMPORTANT:

Plumbing shall be installed in accordance with the International Plumbing Code and any local codes and ordinances.

Use copper tubing or Whirlpool supply line, Part Number 8212547RP, and check for leaks.

Install tubing only in areas where temperatures will remain above freezing.

Tools needed

Gather the required tools and parts before starting installation:

Flat-blade screwdriver

⁷⁄₁₆" and ¹⁄₂" open-end wrenches or two adjustable wrenches

¹⁄₄" nut driver

NOTE: Do not use a piercing-type or ³⁄₁₆" (4.76 mm) saddle valve which reduces water flow and clogs more easily.

Connecting the Water Line

1.Turn off main water supply. Turn on nearest faucet long enough to clear line of water.

2.Using a ¹⁄₂" copper supply line with a quarter-turn shutoff valve or the equivalent, connect the ice maker as shown.

NOTE: To allow sufficient water flow to the ice maker a minimum ¹⁄₂" size copper supply line is recommended.

A

B

A.Bulb

B.Nut

3.Now you are ready to connect the copper tubing. Use ¹⁄₄" (6.35 mm) OD soft copper tubing for the cold water supply.

Ensure that you have the proper length needed for the job. Be sure both ends of the copper tubing are cut square.

Slip compression sleeve and compression nut on copper tubing as shown. Insert end of tubing into outlet end squarely as far as it will go. Screw compression nut onto outlet end with adjustable wrench. Do not overtighten.

A B

C

A. Compression sleeve

C. Copper tubing

B. Compression nut

 

4.Place the free end of the tubing into a container or sink, and turn on main water supply and flush out tubing until water is clear. Turn off shutoff valve on the water pipe.

NOTE: Always drain the water line before making the final connection to the inlet of the water valve to avoid possible water valve malfunction.

5.Bend the copper tubing to meet the water line inlet which is located on the back of the ice maker cabinet as shown. Leave a coil of copper tubing to allow the ice maker to be pulled out of the cabinet or away from the wall for service.

REAR VIEW

A

B

C

D

A. Water supply tube clamp

B. Vent hose (drain pump models only)

C. Inlet water tube clamp and supply line connector

D. Drain hose (drain pump models only)

6.Remove and discard the short, black plastic tube from the end of the water line inlet.

7.Thread the nut onto the end of the tubing. Tighten the nut by hand. Then tighten it with a wrench two more turns. Do not overtighten.

NOTE: To avoid rattling, be sure the copper tubing does not touch the cabinet’s side wall or other parts inside the cabinet.

A

B

C

D

A. Line to ice maker

 

C. Ferrule (purchased)

B. Nut (purchased)

 

D. Supplied line from ice maker

8.Install the water supply tube clamp around the water supply line to reduce strain on the coupling.

9.Turn shutoff valve ON.

10.Check for leaks. Tighten any connections (including connections at the valve) or nuts that leak.

7

Image 7
Contents W10282143B USE & Care GuideManual DE USO Y Cuidado Guide D’UTILISATION ET D’ENTRETIENÍndice Table of ContentsTable DES Matières Tools and Parts ICE Maker SafetyInstallation Instructions Custom Panel Dimensions Top of Panel Option 1 Without Hinge-Side Spacer Option 2 With Hinge-Side Spacer Front of PanelLocation Requirements Unpack the Ice MakerRecommended grounding method Electrical RequirementsWater Supply Requirements LevelingConnect Water Supply Connecting the Water LineRear View Gravity Drain System Install Custom Overlay PanelConnecting the Drain Drain Connection#8 x ¹⁄₂ Pan-head wood screw Adhesive pads Custom panel Ice Maker DoorRemove Door Hinge pinNormal Sounds ICE Maker USE Using the ControlsHow Your Ice Maker Works Ice Maker System CleaningICE Maker Care Exterior SurfacesInterior Components Vacation and Moving CareTo shut down the ice maker Your ice maker will not operate TroubleshootingFor ice makers with a drain pump installed Ice Maker OperationIce Quality Assistance or ServicePlumbing Problems Ice ProductionDisclaimer of Representations Outside of Warranty JENN-AIRICE Maker WarrantyThree Year Limited Warranty Parts and Labor Items Excluded from WarrantyHerramientas y piezas Dimensiones del panel hecho La medidaSeguridad DE LA Fábrica DE Hielo Instrucciones DE InstalaciónParte superior del panel Opción 1 Sin el espaciador del lado de la bisagraOpción 2 Con el espaciador del lado de la bisagra Frente del panelRequisitos de ubicación Desempaque la fábrica de hieloMétodo recomendado para la conexión a tierra Requisitos eléctricosRequisitos del suministro de agua NivelaciónConexión de la tubería de agua Conexión del suministro de aguaVista Posterior Conexión del desagüe Conexión del desagüeSistema de desagüe por gravedad Sistema de la bomba de desagüe en algunos modelosPuerta de la fábrica de hielo Instale el panel de revestimiento Hecho a la medidaSaque la puerta Volver a colocar la puerta Bisagra superiorBisagra inferior Invertir las bisagrasProceso de elaboración de hielo USO DE LA Fábrica DE HieloSonidos normales Cómo funciona su fábrica de hieloUso de los controles Cuidado DE LA Fábrica DE HieloLimpieza Tapa de la rejilla de corte Tornillos CondensadorComponentes interiores Un condensador sucio u obstruidoPara apagar la fábrica de hielo Cuidado durante las vacaciones y MudanzasTornillo de mariposa Soporte de la pala para el hielo Funcionamiento de la fábrica de hielo Solución DE ProblemasProducción de hielo Ayuda O Servicio Técnico Problemas de plomeríaCalidad del hielo Exclusión DE Garantías Implícitas Garantía DE LA Fábrica DE Hielo JENN-AIRExclusiones DE LA Garantía Esta garantía limitada no cubreExclusión DE Declaraciones Fuera DE LA Garantía Outillage et pièces Instructions D’INSTALLATIONDimensions du panneau personnalisé Sécurité DE LA Machine À GlaçonsPartie supérieure du panneau Option 1 Sans cale despacement côté charnièreOption 2 Avec cale despacement côté charnière Avant du panneauDéballage de la machine à glaçons Exigences demplacementNivellement Méthode de mise à la terre recommandéeSpécifications électriques Spécifications de l’alimentation en eauRaccordement du tuyau d’eau Raccordement à la canalisation d’eauVUE Arrière Raccordement du drain de vidange Raccordement au drain de vidangeVidange par gravité Système avec pompe de vidange sur certains modèlesAxe de la charnière Installation du panneau décoratif personnaliséPorte de la machine à glaçons Dépose de la porteCharnière inférieure Réinstallation de la porteInversion des charnières Charnière supérieureFabrication de la glace Utilisation DE LA Machine GlaçonsSons normaux Fonctionnement de la machine GlaçonsEntretien DE LA Machine Glaçons Utilisation des commandesNettoyage Bac à eau Vis à ailette du bac à eau Capuchon de vidange CondenseurComposants intérieurs Un condenseur sale ou obstruéArrêt de la machine à glaçons Précautions à prendre avant les vacances ou un déménagementVis à ailette Support de pelle à glace La machine à glaçons semble bruyante DépannageProduction de glaçons La machine à glaçons ne fonctionne pasQualité des glaçons Assistance OU ServiceProblèmes de plomberie La présente garantie limitée ne couvre pas Garantie DE Machine À Glaçons JENN-AIRGarantie Limitée DE Trois ANS Pièces ET MAIN-D’ŒUVRE Éléments Exclus DE LA Garantie2011 All rights reserved W10282143B