Extron electronic DVS 605 Information request, Backup/restore configuration, Product naming, type

Page 61
Information request

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

 

 

Information request

 

 

General information

I/i

VidX!AudX!•VtypX#StdX1)BlkX3!HrtX1#VrtX1#

 

 

PipX!]

 

Backup/restore configuration NOTE: Aud “X!” response is a “-” on the non audio model. “Vtyp” returns the detected input type (X!*\) . E1*{config type} NOTE: Blk “X3!” response is “0” unless video is muted, then the response is “1”

Query firmware

Q/q

x.xx]

View firmware version.

version

 

 

 

Query full firmware

*Q/*q

x.xx.xxxx]

View full firmware version details.

version

 

 

 

Query part number

N/n

zz-zzz-zz]

View part number.

View internal

E20STAT}

Stat20X1!]

Temperature in degrees Celsius.

temperature

 

 

 

Backup/restore configuration

Cfg1*{config NOTE: {config type} = 0 = IP config (ip.cfg), 1 = event config (event.cfg), 2 = unit specific parameters (box.cfg), type}] The files are stored on directory /nortxe-backup created on the unit by the “save” commands.

Save device

E1*{config type}

Cfg1*{config

Save unit configuration to file system.

configuration

XF}

type}]

 

Restore device

E0*{config type}

Cfg1*{config

Restore unit configuration from file system.

configuration

XF}

type}]

 

 

 

 

 

Product naming

 

 

 

E0*{config type} NOTE: The 24 superscript shown below indicates that the user will get an E24 error on an IP Link-based device Product naming (such as the DVS 605) if the user is not logged in as Administrator when trying to alter names.

Set unit name 24

EX1@CN}

IpnX1@]

Set unit name to X1@.

Set unit name to

E•CN}

IpnX10)]

Set unit name to default X10).

factory default 24

 

 

 

View unit name

ECN}

X1@]

View unit name.

EX1@CN} NOTE: X! = Input selection, 1 to 5

X# = Input video format, 0 = No signal detected (only valid for detected input format query, such as X!*\), 1 = RGB,

2 = YUV Auto, 3 = RGBcvS, 4 = S-video, 5 = Composite, 6 = DVI/HDMI (Only available for IN3, IN4, and IN5)

X1) = Input standard, 0 = No signal detected (current input), 1 = NTSC 3.85, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM

- = N/A (occurs when input is an active RBG, YUV Auto [but not NTSC/PAL], or HDMI signal

X1! = Internal temperature (in degrees Celsius)

X1@ = Unit name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-).

The first character must be an alpha character. The last character must not be a minus. No blank or space characters are

permitted, and no distinction is made between upper- and lowercase.

X1# = Horizontal and vertical frequencies (format is three digit with single decimal and leading zeros for example, 075.3)

X3! = Video mute: 0 = off/disable, 1 = on/enable (mute to black)

X10) = Default name: combination of model name and last 3 pairs of MAC address (for example DVS-605-Series-07-8C-EC)

DVS 605 • SIS Communication and Control

55

Image 61
Contents with Seamless Switching SCALERS AND SIGNAL PROCESSORSUser Guide HDCP-CompliantScalerSafety Instructions • English Safety InstructionsChinese Simplified(简体中文) Instructions de sécurité • FrançaisCopyright FCC Class A NoticeTrademarks Software Commands Specifications AvailabilityConventions Used in this Guide NotificationsUsing the Default Web Pages ContentsSIS Communication and Control Mounting the DVS DVS 605 Series Description IntroductionLicensed Third-partySoftware Used in the DVS Licensed Third-partySoftware Used in the DVSPackage LicenseVideo Inputs Key FeaturesVideo Outputs General AudioDVS 605 • Introduction DVS 605 • Introduction Controlling the DVS Rear Panel Connections DVS 605 Rear Panel Features — All ModelsRear Panel Cabling FigureDVS using the LockIt bracket as follows Figure 2. LockIt Bracket Mounting Options Audio Input Connector WiringFigure Figure 5. Audio Output Connector Wiring Figure 4. Audio Output Connector WiringFigure 6. RJ-45LAN Connector Wiring DVS 605 • Rear Panel Connections •Other DVS 605 Operating Features •Front Panel Overview •Powering UpFigure 7. DVS 605 Front Panel Features OperationDefault Display Cycle Powering UpMenu Navigation Using Front Panel Controls Figure 8. Typical Default Display CycleFigure 9. Top Level Menus Menu OverviewDVS 605 • Operation Figure 10. Main MenuFigure 11. User Preset Menu User PresetsPicture Control Figure 12. Picture Control MenuFigure 13. Input Configuration Menu Input ConfigurationInput video types InputResolutions and Refresh Rates Output ConfigurationFigure 14. Output Configuration Menu Sync Polarity Analog Output FormatHDMI Format HDCP NotificationHDCP Authorized HDCP Status: Inputs & OutputsGenlock/AFL Modes Genlock/AFL Offset Description Audio Delay Setting Audio Configuration All ModelsFigure 17. Audio Configuration Menu Figure 18. Advanced Configuration Menu Advanced ConfigurationAspect Ratio Auto-Image Auto-Imagethreshold settingsAuto Memory Overscan Switch typeTest pattern OSD durationFactory Reset View Comm SettingsFigure 21. Edit Comm Settings Menu Exit MenuFigure 22. Front Panel Lockout Front Panel Lockout Executive ModesEnable Executive Mode Disable Executive ModeDVS 605 Operation Window vs. Image Size Position — An OverviewFront Panel Activation Picture-in-picturePIP ModeNOTES Figure 24. Default Main and PIP Window Layouts PIP PresetsPower Save Other DVS 605 Operating FeaturesCustom EDID/Custom Output Resolution Screen SaveThe OSD Bug Hardwired IR PortAudio Format Audio SourceDVS 605 Reset Mode Summary Resetting the UnitFigure 25. Reset Mode Comparison Reset All IP Reset to Factory Defaults SettingsCopyright Information SIS Communication and Control•Commands and Responses Host to Scaler CommunicationsPassword Information Commands and ResponsesError Responses Error Response ReferencesDVS 605 • SIS Communication and Control Symbol DefinitionsDVS 605 SIS Communication and Control Figure 29. SIS Command EDID TableDVS 605 SIS Communication and Control DVS 605 • SIS Communication and Control DVS 605 • SIS Communication and Control SIS IP command definitionsDVS 605 • SIS Communication and Control Command SIS Command and Response TableASCII Command ResponseInput name Additional DescriptionAuto-Image Horizontal startASCII Command CommandResponse Additional DescriptionVideo mute Picture AdjustmentsColor TintVertical position window Horizontal position windowHorizontal position image Vertical position imagePower save mode Output ConfigurationHorizontal size image Output scaler rateVolume control audio models only Audio Configuration Audio mute global settingsAudio delay available on all models CommandAudio output format Audio input formatAudio follow CommandUser preset name Presets User presetsInput presets Input preset nameTest pattern Advanced ConfigurationFreeze Auto memories per input Effect duration Video effect Front panel security lockout Executive Mode HDCP notification green screen/messageGenlock Video signal presenceGenlock/AFL Offset CommandReset commands Hardwired IR portPicture In Picture PIP on/offInformation request Backup/restore configurationProduct naming CommandFirmware version requests Ethernet data portCommand ASCII TelnetInformation requests IP setup commandsCommand ASCII TelnetNOTE: E X12!CA File erase commands Directory commandsRe-mapport designations CommandAccessing the Default Web Pages Using the Default Web Pages•Accessing the Default Web Pages Navigating the Default Web PagesTo check compatibility view settings Navigating the Default Web PagesTurning Off Compatibility Mode AV Controls Panel Configuration PagesAuto-Imagebutton AV input buttons inputsVideo and audio mute buttons Breakaway audio check box audio models onlyFreeze button Figure 34. Input Configuration Panel Signal typeInput renaming RGB ScaledFilm Detect Aspect ratioAuto-Image Auto MemoryAnalog signal format ResolutionFigure 35. Input Configuration Panel Refresh rateSwitch transition Digital output signal formatGenlock Test patternFigure 36. EDID Minder Page EDID Minder PageFigure 37. Assigning EDIDs Assigning EDIDsSignal Sampling Image Settings PageFigure 38. Image Settings Page Settings Included Within Presets User PresetsSetting User PresetOverscan Input PresetsFigure 40. PIP Settings Page PIP Settings PagePIP input selection Snap PIP toSize and Position PIP picture controlsHorizontal Size and Vertical Size fields Horizontal Pos and Vertical Pos fieldsFigure 41. PIP Preset Default Window Locations PIP presetsFigure 42. Audio Config Page Audio Settings PageNone •2-CHDigital •Full DigitalStereo Dual MonoFigure 43. Preset Management Page Preset Management Pagea.Recall: Inputs, Size & Position, or b.Recall: Size & Position OnlyFigure 44. Device Settings Page Device Settings Page1.Select the Enable On Screen Display check box Screen Saver SettingsOn Screen Display Message HDCP NotificationAuto Switch Unit Information Page Hardware PagesFigure 46. Unit Information Page See Licensed Third-partySoftware Used in theFigure 48. Connection Settings Page Connection Settings PageDevice Name Page Figure 47. Device Name PageEthernet Settings RS-232SettingsFirmware Loader Page Figure 49. Firmware Loader PageFigure 50. Executive/Power Mode Page Executive/Power Mode PageExecutive Mode Date and Time Page Power ModeMute Video and Sync Figure 51. Date and Time PageFigure 52. Password Page Password PageFigure 53. Reset Device Page Reset Device Pagedevice name, DHCP setting, and port mapping Mounting Tabletop PlacementMounting the DVS UL Guidelines for Rack Mounted DevicesFurniture Mounting Rack MountingFigure 54. Rack Mounting the DVS Figure 55. Furniture Mounting the DVSUSA, Canada, South America Extron Warrantyand Central America Japan
Related manuals
Manual 4 pages 24.4 Kb