Hoshizaki 73168 service manual Cabinet Defrost

Page 37

4. Cabinet Defrost

Problem

Possible Cause

 

 

Remedy

[1]

Cabinet fan motors

a) Cabinet Fan Relay

1.

Bad contacts (closed).

1.

Check for continuity and

 

on.

 

 

 

 

replace.

 

 

b) Control Board

1.

Defective.

1.

Replace.

[2]

Evaporator does

a) Defrost Thermistor

1.

Defective.

1.

See "II.E. Thermistor

 

not defrost

 

 

 

 

Check."

 

completely.

b) Defrost

1.

Not enough defrosts

1.

Factory default is once

 

 

 

 

occurring per day.

 

every 6 hours. See "II.D.5.

 

 

 

 

Operation in humid

 

Service Menu."

 

 

 

 

conditions.

 

 

 

 

c) Defrost Heater

1.

Defective.

1.

Replace heater.

 

 

d) Defrost Thermostat

1.

Defective, turning off

1.

Replace defrost thermostat.

 

 

 

 

heaters prematurely,

 

 

 

 

 

 

or fused open.

 

 

 

 

e) Cabinet Liquid Line

1.

Does not close.

1.

Check and replace.

 

 

Valve

 

 

 

 

[3]

Defrost cycle too

a) Defrost

1.

Not enough defrosts

1.

Factory default is once

 

long. (E3 Defrost

 

 

occurring per day.

 

every 6 hours. See "II.D.5

 

Alarm)

 

 

Operation in humid

 

Service Menu."

 

 

 

 

conditions.

 

 

 

 

b) Defrost Thermistor

1.

Defective.

1.

Replace.

 

 

c) Defrost Heater

1.

Defective.

1.

Replace heater.

 

 

d) Defrost Thermostat

1.

Defective, turning off

1.

Replace defrost thermostat.

 

 

 

 

heaters prematurely,

 

 

 

 

 

 

or fused open.

 

 

 

 

e) Control Board

1.

Defective.

1.

Replace.

37

Image 37
Contents Superior Degree Reliability Number Issued Revised Hoshizaki AMERICA, INC Contents Page Page Serious injury Important Safety InformationIndicates important information about the use and care UnitDimensions Specifications Nameplate RatingsII. General Information Construction Power Switch ON, Rail Cooling Switch Normal or LOW Power Switch ON, Rail Cooling Switch OFFSequence of Operation Cabinet Defrost Cool Down RestartRail Defrost Cabinet Defrost Power Switch ON, Rail Cooling Switch OFFOperation Power Switch ON, Rail Cooling Switch OFF CabinetRail Cooling Power Switch ON, Rail Cooling Switch Normal or LOW PositionCabinet and Rail Cooling Control Board Location Control BoardControl Board Layout Front RearAlarm Signal LED Display and Service Lock-OutService Menu Compressor Short Cycle ProtectionSwitch Settings Controls and AdjustmentsTemperature Display Energy Saving Mode Temperature SetpointCabinet Defrost Temperature Correction Factor Service Menu Access Service MenuService Menu Chart Control Board Check Procedure Alarm SignalsControl Board Replacement Perimeter Heater Thermistor CheckCompressor Protector Alarm Signals III. Service DiagnosisAlarm Priority Problem Reset, Corrections, and Adjustments Reset Options High Temperature Alarm E1Low Temperature Alarm E2 Cabinet Defrost Alarm E3 High Condenser Temperature Alarm clogged filter E7 Possible Causes Defrost Thermistor cabinet Malfunction Alarm E85a. Secondary Defrost Thermistor Rail, not used Condenser Thermistor Malfunction Alarm E9 Control Board Alarms EA and ED Service ChartNo Operation Cabinet Cooling Problem Possible Cause Remedy Rail Cooling Cabinet Defrost Other Service for Refrigerant Lines IV. Removal and Replacement of ComponentsRefrigerant Recovery Evacuation and Recharge R-404A BrazingPage Refrigerant Recovery Procedure Removal and Replacement of Refrigeration System CartridgePage Refrigeration System Pump‑Down Procedure Page Defrost Thermistor Rail Thermistor Removal and Replacement of Compressor Removal and Replacement of Cabinet Evaporator Removal and Replacement of Expansion Valve Removal and Replacement of Liquid Line Valve Removal and Replacement of Condenser Cabinet Thermistor Removal and Replacement of Thermistors and ThermostatDefrost Thermistor Rail Thermistor Defrost ThermostatCondenser Thermistor clogged filter Removal and Replacement of Defrost HeaterCabinet Fan Motor Removal and Replacement of Fan MotorsRail Fan Motor Condenser Fan MotorDoor Re-Hinging and Drawer Conversion Removal and Replacement of Door GasketWork Surface Cleaning and Maintenance InstructionsExterior Rail and Rail CoverCabinet Interior Door/Drawer GasketsPower Supply Connection MaintenanceRail Condensate Pan Air FilterShutdown and Long Storage HPR100A-D Refrigeration Circuit VI. Technical InformationHPR46A-D Wiring Diagrams2a. HPR72A-D Auxiliary Code U-5 and Earlier 2b. HPR72A-D Auxiliary Code U-6 and Later Awaiting Data