Hoshizaki 73168 service manual Problem Possible Cause Remedy

Page 35

Problem

Possible Cause

 

 

Remedy

[1]

Cabinet

g)

Defrost

1.

Defrost time

1.

See "4. Cabinet Defrost."

 

temperature too

 

 

 

insufficient to remove

 

 

 

high. (continued)

 

 

 

frost. Operation in

 

 

 

 

 

 

 

humid conditions.

 

 

 

 

 

 

2. Incomplete defrost.

2. See "4. Cabinet Defrost."

 

 

h)

Air Filter or Condenser

1.

Clogged, dirty.

1.

Clean.

 

 

i)

Cabinet Fan Motor

1.

Defective.

1.

Check and replace.

 

 

j)

Cabinet Liquid Line

1.

Does not open.

1.

Check and replace.

 

 

 

Valve

 

 

 

 

 

 

k)

Service Valve(s)

1.

Partially or completely

1.

Confirm service valve is

 

 

 

 

 

closed.

 

open.

 

 

l)

Refrigerant

1.

Leak.

1.

Recover, repair leak,

 

 

 

 

 

 

 

replace drier, evacuate, and

 

 

 

 

 

 

 

recharge.

 

 

m) Expansion Valve

1.

Operating erratically.

1.

Check and replace.

 

 

n)

Compressor

1.

Defective.

1.

See "1.[3] Compressor will

 

 

 

 

 

 

 

not start or stops operating."

 

 

o)

Control Board

1.

Defective.

1.

Replace.

[2]

Cabinet temperature

a)

Setpoint and/or

1.

Incorrect.

1.

Correct setting(s).

 

too low.

 

Temperature

 

 

 

See "II.D.4.c) Temperature

 

 

 

Correction Factor

 

 

 

Setpoint" or  

 

 

 

 

 

 

 

"II.D.4.f) Temperature

 

 

 

 

 

 

 

Correction Factor" for

 

 

 

 

 

 

 

defaults.

 

 

b)

Frozen Food

1.

Frozen food recently

1.

Allow time for unit to return

 

 

 

 

 

placed in refrigerator.

 

to setpoint temperature.

 

 

c)

Cabinet Thermistor

1.

Defective.

1.

Check and replace.

 

 

d)

Cabinet Liquid Line

1.

Does not close.

1.

Check and replace.

 

 

 

Valve

 

 

 

 

 

 

e)

Compressor Relay

1.

Defective; contacts

1.

Replace.

 

 

 

 

 

welded.

 

 

 

 

f)

Control Board

1.

In alarm or defective.

1.

See "III.A Alarm Signals" or

 

 

 

 

 

 

 

replace.

35

Image 35
Contents Superior Degree Reliability Number Issued Revised Hoshizaki AMERICA, INC Contents Page Page Unit Important Safety InformationSerious injury Indicates important information about the use and careDimensions Specifications Nameplate RatingsII. General Information Construction Sequence of Operation Power Switch ON, Rail Cooling Switch OFFPower Switch ON, Rail Cooling Switch Normal or LOW Cabinet Defrost Cool Down RestartRail Defrost Cabinet Defrost Power Switch ON, Rail Cooling Switch OFFOperation Power Switch ON, Rail Cooling Switch OFF CabinetRail Cooling Power Switch ON, Rail Cooling Switch Normal or LOW PositionCabinet and Rail Cooling Control Board Location Control BoardControl Board Layout Front RearCompressor Short Cycle Protection LED Display and Service Lock-OutAlarm Signal Service MenuTemperature Display Controls and AdjustmentsSwitch Settings Cabinet Defrost Temperature SetpointEnergy Saving Mode Temperature Correction Factor Service Menu Access Service MenuService Menu Chart Control Board Replacement Alarm SignalsControl Board Check Procedure Compressor Protector Thermistor CheckPerimeter Heater Alarm Signals III. Service DiagnosisAlarm Priority Problem Reset, Corrections, and Adjustments Reset Options High Temperature Alarm E1Low Temperature Alarm E2 Cabinet Defrost Alarm E3 High Condenser Temperature Alarm clogged filter E7 5a. Secondary Defrost Thermistor Rail, not used Defrost Thermistor cabinet Malfunction Alarm E8Possible Causes Condenser Thermistor Malfunction Alarm E9 No Operation Service ChartControl Board Alarms EA and ED Cabinet Cooling Problem Possible Cause Remedy Rail Cooling Cabinet Defrost Other Refrigerant Recovery IV. Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404A BrazingPage Refrigerant Recovery Procedure Removal and Replacement of Refrigeration System CartridgePage Refrigeration System Pump‑Down Procedure Page Defrost Thermistor Rail Thermistor Removal and Replacement of Compressor Removal and Replacement of Cabinet Evaporator Removal and Replacement of Expansion Valve Removal and Replacement of Liquid Line Valve Removal and Replacement of Condenser Defrost Thermistor Removal and Replacement of Thermistors and ThermostatCabinet Thermistor Rail Thermistor Defrost ThermostatCondenser Thermistor clogged filter Removal and Replacement of Defrost HeaterCabinet Fan Motor Removal and Replacement of Fan MotorsRail Fan Motor Condenser Fan MotorDoor Re-Hinging and Drawer Conversion Removal and Replacement of Door GasketWork Surface Cleaning and Maintenance InstructionsDoor/Drawer Gaskets Rail and Rail CoverExterior Cabinet InteriorAir Filter MaintenancePower Supply Connection Rail Condensate PanShutdown and Long Storage HPR100A-D Refrigeration Circuit VI. Technical InformationHPR46A-D Wiring Diagrams2a. HPR72A-D Auxiliary Code U-5 and Earlier 2b. HPR72A-D Auxiliary Code U-6 and Later Awaiting Data