SAFETY THERMOSTAT:
Incorrect Installations
✔
Probe fully inserted in tube
Wiring is properly
connected
1 | 2 | 3 | Safety thermostat | |
|
|
| 1 probe is not | |
|
|
| completely | |
|
|
| inserted into | |
|
|
| tubing. | |
|
|
| Safety thermostat | |
|
|
| 2 probe is removed | |
|
|
| from tubing. | |
✘ | ✘ | ✘ | Safety thermostat | |
3 electrical | ||||
Probe | Probe | Thermostat | connection is | |
removed | removed | electrically | bypassed. | |
partially | completely | bypassed | ||
|
Low Water Level Probe:
✔Probe properly attached
(A)
(B)
Probe bypassed by | ✘ | Probe bypassed by |
✘ running (A) an | (B) grounding the | |
additional wire |
| connecting wire |
Operating
Thermostat:
265º | 260º - 270º | |
MAXIMUM | ||
| ||
| ✔ KETTLE | |
| TEMPERATURE |
Air
Switch:
✔
Wiring is properly connected
If maximum temperature is not in this range (on empty kettle), refer to the
CALIBRATING
PROCEDURE.
Incorrect Installation
✘
Switch electrically bypassed