GAS
It is recommended that a sediment trap (drip leg) be installed in the gas supply line. If the gas pressure exceeds 14” water column, a pressure regulator must be installed, to provide a maximum of 14” water column gas pressure to the gas control valve.
Connect the gas supply piping to the input side of the gas control valve. Location and pressure data are shown on the specification sheet.
Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI
The appliance and its individual
ELECTRICAL
Electrical installation must be in accordance with local codes and/or the National Electric Code ANSI/NFPA 70- 1990 (USA) or the Canadian Electrical Code CSA Standard C22.1 (Canada). The kettle must be electrically grounded by the installer.
A separate fused disconnect switch must be supplied and installed in the high voltage electrical supply line.
The wire gauge size and electric supply must match the power requirements specified on the kettle’s rating plate. The waterproof conduit enclosed permanent copper wiring must be adequate to carry the required current at the rated voltage. Refer to the specification sheet or rating label for electrical specifications and location of electrical connections.
Remove the screws securing the component cover (located to the left rear side of kettle), and remove the cover. A wiring diagram is affixed to the inside of the cover. Feed conduit enclosed permanent copper wiring through the
with the screws.
WATER
The sealed jacket of the
jacket.
CLEANING
After installation the kettle must be thoroughly cleaned and sanitized prior to cooking.
WARRANTY
Our Company supports a worldwide network of Maintenance and Repair Centres. Contact your nearest Maintenance and Repair Centre for replacement parts, service, or information regarding the proper maintenance and repair of your cooking equipment
In order to preserve the various agency safety certification (UL, A.G.A., NSF, ASME/Ntl. Bd., etc.), only