FIELD CONVERSION INSTRUCTIONS - Natural Gas to Propane Gas
Power Burner Gas Kettles
| BTU's per | Gas | Water | # of | |
| Hour | Type | Column | Orifices | |
140000 | NAT | 3.5 | 1 | ||
140000 | LP | 3.5 | 1 | ||
|
|
|
| ||
|
|
|
| ||
|
|
|
| ||
190000 | NAT | 3.5 | 1 | ||
190000 | LP | 3.5 | 1 | ||
|
|
|
| ||
|
|
|
| ||
|
|
|
|
TOP COVER
NOTE: Use thread sealant compatible with propane gas on all threaded piping connections.
1.Disconnect electrical connection.
2.Shut off main gas supply and disconnect kettle from supply line.
3.Remove TOP COVER.
4.Remove PLUG and SPRING.
5.Remove GAS ORIFICE and “O” RING.
6.Replace with new GAS ORIFICE and “O” RING.
7.Replace SPRING and PLUG.
8.Replace TOP COVER.
9.Place gas conversion label next to rating label.
10.Reconnect electrical supply.
“O” RING
GAS ORIFICE
SPRING
PLUG
Conversion Parts Required
KGL-40
Part No. | Description | Quantity |
KE95549 | Conversion Label | 1 |
|
|
|
Air Intake Washer | 1 | |
|
|
|
Gas Orifice | 1 | |
|
|
|
“O” Ring | 1 | |
|
|
|
KGL-60 to 100
Part No. | Description | Quantity |
KE95549 | Conversion Label | 1 |
|
|
|
Air Intake Washer | 1 | |
|
|
|
Gas Orifice | 1 | |
|
|
|
“O” Ring | 1 | |
|
|
|