Pitco Frialator L20-332 manual To the PURCHASER, Owner and Store Manager

Page 2

TO THE PURCHASER, OWNER AND STORE MANAGER

Please review these warnings prior to posting them in a prominent location for reference.

TO THE PURCHASER

Post in a prominent location the instructions to be followed in the event that an operator smells gas. Obtain this information from your local gas supplier.

WARNING

DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WARNING

Improper installation, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this appliance.

WARNING

Installation, maintenance and repairs should be performed by a Pitco Authorized Service and Parts (ASAP) company technician or other qualified personnel. Installation, maintenance or repairs by an unauthorized and unqualified personnel will void the warranty.

WARNING

Installation and all connections must be made according to national and local regulations and codes in force.

WARNING

During the warranty period if a customer elects to use a non- original part or modifies an original part purchased from Pitco and/or its Authorized Service and Parts (ASAP) companies, this warranty will be void. In addition, Pitco and its affiliates will not be liable for any claims, damages or expenses incurred by the customer which arises directly or indirectly, in whole or in part, due to the installation of any modified part and/or received from an unauthorized service center.

WARNING

This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.

WARNING

Adequate means must be provided to LIMIT the movement or this appliance without depending on the gas or electrical cord connection. Single appliances equipped with legs must be stabilized by installing anchor straps. All appliances equipped with casters must be stabilized by installing restraining chains.

WARNING

An appliance equipped with casters and a flexible gas line must be connected to the gas supply with a quick disconnect device. This quick disconnect must comply with ANSI Z24.41.

WARNING

DO NOT alter or remove structural material on the appliance to accommodate placement under a ventilation hood.

WARNING

This appliance is intended for professional use only and should be operated by fully trained and qualified personnel.

WARNING

If the appliance is equipped with a power cord and it is damaged, it must be replaced by a Pitco Authorized Service and Parts (ASAP) company technician, or a similarly qualified person in order to avoid a hazard.

WARNING

The power supply must be disconnected before servicing, maintaining or cleaning this appliance.

WARNING

WARNING

DO NOT attempt to move this appliance or transfer hot liquids from one container to another when the unit is at operating temperature or filled with hot liquids. Serious personal injury could result if skin comes in contact with the hot surfaces or liquids.

WARNING

DO NOT sit or stand on this appliance. The appliance’s front panel, tank, splash back, tank cover, workshelf, drain board is not a step. Serious injury could result from slipping, falling or contact with hot liquids.

WARNING

NEVER use the appliance as a step for cleaning or accessing the ventilation hood. Serious injury could result from slips, trips or from contacting hot liquids.

WARNING

The oil/shortening level should NOT fall below the minimum indicated level line at any time. The use of old shortening can be dangerous as it will have a reduced flash point and be more prone to surge boiling.

WARNING

The contents of the crumb catch and/or filter pan of any filter system must be emptied into a fireproof container at the end of each day. Some food particles can spontaneously combust if left soaking in certain types of oil or shortening.

WARNING

Completely shut the appliance down when shortening/oil is being drained from the appliance. This will prevent the appliance from heating up during the draining and filling process. Serious injury can occur.

WARNING

This appliance is intended for indoor use only.

WARNING

DO NOT operate appliance unless all panels and access covers are attached correctly.

WARNING

It is recommended that this appliance be inspected by a qualified service technician for proper performance and operation on a yearly basis.

WARNING

There is an open flame inside this appliance. The unit may get hot enough to set nearby materials on fire. Keep the area around the appliance free from combustibles.

WARNING

DO NOT supply the appliance with a gas that is not indicated on the data plate. If you need to convert the appliance to another type of fuel, contact your dealer.

WARNING

DO NOT use an open flame to check for gas leaks!

WARNING

If gas flow to appliance is interrupted, or pilots extinguish, wait 5 minutes before attempting to relight the pilot to allow any residual gas in appliance to dissipate.

WARNING

Ensure that the appliance can get enough air to keep the flame burning correctly. If the flame is starved for air, it can give off a dangerous carbon monoxide gas. Carbon monoxide is a clear odorless gas that can cause suffocation.

The appliance is NOT jet stream approved. DO NOT clean the appliance with a water jet.

ii

L20-332, rev.1 (05/11)

Image 2
Contents English To the PURCHASER, Owner and Store Manager Operation Features Specific to Models with Filters Model SG6H FryerReplacing the Filter Media if Equipped ANNUAL/PERIODIC Preventative Maintenance and InspectionFiltering with a Filter Drawer if Equipped Control BOX & Electrical ComponentsSelf Cleaning Burner System not on ALL Models SG6H SFSG6H Accessories DescriptionChecking Your NEW Appliance Model SG6H Fryerinstallation Installation Clearances LEG/CASTER Installation and LevelingQuick Disconnect Connection Fuel Supply Line Leak and Pressure TestingGAS Connection Installation CE GAS Table not Applicable to ALL ModelsElectrical Connections Ventilation and Fire Safety Systems InspectionLighting Instructions Initial AdjustmentsFilling the Appliance ON/OFFOFF Main Burner System Adjustment Initial Cleaning Operational Features Cook Tank Front Panel Self Cleaning Burner System if equippedFilter Pump Reset Button Drain Valve Handle Blue Shown in the closed positionSG6H Filling the Cooker TankTank Capacity Model Filling the Tank with Liquid ShorteningModel SG6H Fryer Appliance Start UP Cooking Tips Typical Timer ButtonsCooking Fry Thickness 350F 360F 370FComplete Shutdown Standby ModeAppliance Shutdown Daily Preventative Maintenance Flush Hose Operation if EquippedPreventative Maintenance Appliance InspectionCleaning the Cabinet Cleaning the Cook TankDo not leave the appliance unattended during cleaning Filter Cleaning if EquippedMonthly Preventative Maintenance Boil OUT ProcedureTemperature Check Mechanical InspectionFilter System if Equipped Ventilation HoodDrain Valve Interlock Power FailureHigh Temperature Limit L20-332, rev 05/11 Problem Probable Causes Corrective Actions Troubleshooting ChartsFryer Troubleshooting Chart Filter Troubleshooting Chart if EquippedTroubleshooting Display Explanation ActionL20-332, rev 05/11

L20-332 specifications

The Pitco Frialator L20-332 is an exceptional commercial deep fryer designed for high-volume frying operations. Delivers reliability, efficiency, and advanced technology tailored for busy kitchens, this unit is a top choice for restaurants, cafes, and catering services. Its robust construction and innovative designs make it ideal for frying a variety of foods, from crispy French fries to golden chicken wings.

One of the standout features of the L20-332 is its high production capacity. With a generous 40 lbs. oil capacity per tank, the fryer is capable of supporting large batches, making it possible to keep up with customer demand during peak hours. The fryer is equipped with two fry tanks, providing a total oil capacity of 80 lbs., which allows chefs to prepare multiple items simultaneously, enhancing productivity and efficiency.

The Pitco Frialator L20-332 incorporates advanced heating technology that ensures even heating throughout the oil. This unit utilizes a highly efficient gas burner system that optimizes energy consumption while delivering consistent frying temperatures. The ability to quickly recover heat after food is added ensures that cooks maintain optimal frying conditions without significant temperature drops, which is crucial for achieving perfectly cooked food.

Additionally, this fryer features a durable stainless steel exterior that not only enhances its aesthetic appeal but also makes it easy to clean and maintain. The stainless steel construction resists rust and corrosion, ensuring longevity even in the busiest kitchen environments. Its adjustable legs allow for easy installation and adaptability to various kitchen layouts.

Safety is paramount in any commercial kitchen, and the L20-332 addresses this with effective features such as an integrated high-limit temperature control and a manual reset for safe operation. An easily accessible drain valve simplifies oil changes and maintenance, allowing for efficient cleaning routines.

Easy-to-use controls provide operators with precise temperature settings and cooking times, ensuring consistency and quality in every dish. The design of the fryer also includes a built-in filtration system that extends oil life and boosts the flavor of fried products, resulting in cost savings for the business.

In summary, the Pitco Frialator L20-332 is a powerful and reliable deep fryer equipped with advanced features designed for high-volume cooking. Its combination of efficient heating technology, user-friendly controls, and durable materials make it an ideal addition to any commercial kitchen looking to maximize productivity while delivering exceptional food quality.