Omega Engineering 20, 48, 30 ProgramsMethods00 Information Configuration, Set password to select

Page 17
To edit a field or step in an existing program

To edit a field or step in an existing program

ProgramsMethods[0][0] Information Configuration

[ProgramsMethods[0][0] Information Configuration[ ,  to select ] , Set password to select ]

DONNA [7] Run programmethod

View programmethod Edit programmethod Copy programmethod Delete programmethod

Set password

[Edit a selected field or step , to select ]

When the unit is switched on the display will show this screen.

If known, type in the ‘Speed dial’ number for the required program and press “Enter” This will take you directly to the required program.

If you do not know the ‘Speed dial’ number, press “Enter” to access the list of stored programs.

Either:

1.Scroll to the required program using the “Up Arrow” or “Down Arrow” keys

or

2.Type the first letter of the program name in the ‘New program’ field; this will then list all the program names

beginning with that letter. Use the “Up

Arrow” or “Down Arrow” keys to select the required program.

Press “Enter” to accept

The full set of options for a program is shown here; these are shown on the LCD screen three lines at a time.

Use the “Down Arrow” and/or the “Up

Arrow”keys to select the option you require.

Press the “Enter” key

to select the

option.

 

Edit a selected field or step

Select ‘Edit program’ and a screen similar to this will appear.

Use the “Down arrow” and/or the “Up

arrow” keys to select the field or step you want to edit.

You can now edit the active field or step by first pressing the “Enter” key

17

Image 17
Contents Thermal Cyclers TCY 20, 25, 30User’sGuide Shop online atInternet e-mail info@omega.com OMEGAnet Online Service omega.comServicing North America For immediate technical or application assistanceContents Operator Safety 2. Safety and installation1. Introduction Replacement cable InstallationUnpacking ELECTRICIANWorking Conditions Temperature 3. Cycler TCY SpecificationHeating/Cooling Rate Heated LidDimensions 4. User operation and consumablesPower Heated lid0.5ml Tubes ProgramsMethods00 TCYTCto select Information Configuration5. Front panel controls ConfigurationPrograms MethodsThe End, Finish or Exit key The keysThe Up arrow key The Down arrow keyThe Alpha/Numeric keys 6. Programming the CYCLERStage MethodsPrograms00 Information ConfigurationCycle StepSTEP 2 STEP TEMPLATERun ProgramMethod Option 1 Creating programs using templatesTo save the program To give a program a nameSet password to select ProgramsMethods00 Information Configurationto select DONNA 7 Run programmethod To edit a field or step in an existing program10.0 Post hold72.0ºC 5m0010.0ºCºC UNNAMED #To set a password for a selected program 105ºCProgramming Example programsNew*New- program ** 2 STEP TEMPLATE 5012 3 STEP TEMPLATE Typical 3-Step PCRTo delete a step To insert additional stepsto edit the step as described abovestage to insertTo add a new stage before an existing one To add a new stage at the endThe prompt line will flash between ‘CHANGE TO PAUSE?’ and ‘YES or NO’ To insert a ‘pause’ into a programTemperature profile of incremented Hold Time at step 3 of each cycle To program increment or decrement temperature or timePress “Enter” Press “Pause” to go into edit modetwice to go into edit GEORGE Run ProgrammethodView methodProgram Stopping what you are doingNewprogramMethods Run methodProgramto select To run a program58.0ºC SampleHold @ 72.0ºC7. Information 8. ConfigurationBlock s/nid Unit s/nxxxx ProgramSettingsdefaultsPasswordsFormat memory Settingswill delete ThisSURE ? Passwords9. Notes on transferring protocols from other thermal cyclers Cleaning your CYCLER 10. User maintenanceHeater Block removal Underside of the CYCLER TCY11. Some frequently asked questions Fault Finding 12. Additional informationInsulation testing FusesRETURN REQUESTS/INQUIRIES WARRANTY/DISCLAIMERPRESSURE, STRAIN AND FORCE TEMPERATUREFLOW/LEVEL pH/CONDUCTIVITY