Omega Engineering 25, 48, 20, 30 manual To insert a ‘pause’ into a program

Page 23
To insert a ‘pause’ into a program

To insert a ‘pause’ into a program

To insert a pause after an existing stage, follow the steps for inserting a stage as above.

Highlight the ‘Number cycles’ line then press “Pause”

The prompt line will flash between ‘CHANGE TO PAUSE?’ and ‘YES or NO’.

Press “Enter”

to insert a pause.

The stage number will then be highlighted with ‘Pause’ as the only line.

23

Image 23
Contents Shop online at TCY 20, 25, 30Thermal Cyclers User’sGuideFor immediate technical or application assistance OMEGAnet Online Service omega.comInternet e-mail info@omega.com Servicing North AmericaContents Operator Safety 2. Safety and installation1. Introduction ELECTRICIAN InstallationReplacement cable UnpackingWorking Conditions Heated Lid 3. Cycler TCY SpecificationTemperature Heating/Cooling RateHeated lid 4. User operation and consumablesDimensions Power0.5ml Tubes Information Configuration TCYTCProgramsMethods00 to selectMethods Configuration5. Front panel controls ProgramsThe Down arrow key The keysThe End, Finish or Exit key The Up arrow keyThe Alpha/Numeric keys 6. Programming the CYCLERStep MethodsPrograms00 Information ConfigurationStage CycleOption 1 Creating programs using templates 2 STEP TEMPLATESTEP Run ProgramMethodTo save the program To give a program a nameTo edit a field or step in an existing program ProgramsMethods00 Information ConfigurationSet password to select to select DONNA 7 Run programmethod5m00 Post hold10.0 72.0ºC105ºC UNNAMED #10.0ºCºC To set a password for a selected programTypical 3-Step PCR Example programsProgramming New*New- program ** 2 STEP TEMPLATE 5012 3 STEP TEMPLATEdescribed above To insert additional stepsTo delete a step to edit the step asTo add a new stage at the end to insertstage To add a new stage before an existing oneThe prompt line will flash between ‘CHANGE TO PAUSE?’ and ‘YES or NO’ To insert a ‘pause’ into a programto go into edit mode To program increment or decrement temperature or timeTemperature profile of incremented Hold Time at step 3 of each cycle Press “Enter” Press “Pause”twice to go into edit Stopping what you are doing Run ProgrammethodGEORGE View methodProgramTo run a program Run methodProgramNewprogramMethods to select72.0ºC Sample58.0ºC Hold @Unit s/n 8. Configuration7. Information Block s/nidSettings ProgramSettingsdefaultsxxxx PasswordsFormat memoryPasswords Thiswill delete SURE ?9. Notes on transferring protocols from other thermal cyclers Underside of the CYCLER TCY 10. User maintenanceCleaning your CYCLER Heater Block removal11. Some frequently asked questions Fuses 12. Additional informationFault Finding Insulation testingRETURN REQUESTS/INQUIRIES WARRANTY/DISCLAIMERpH/CONDUCTIVITY TEMPERATUREPRESSURE, STRAIN AND FORCE FLOW/LEVEL