Multiquip DCA-100SSJU Battery Cable Installation, When connecting battery do the following

Page 47

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 43) are properly connected to the battery terminals as shown below. The RED cable is connected to the positive terminal of the battery, and the BLACK cable is connected to the negative terminal of the battery.

Figure 43. Battery Connections

CAUTION :

If the battery cable is connected incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

When connecting battery do the following:

1.DO NOT connect the battery cables to the battery terminals when the Off/Manual/Auto switch is in either the manual or auto position (ON). ALWAYS make sure that the Off/Manual/Auto switch is in the OFF position when connecting the battery.

2.Place a small amount of grease around both battery terminals. This will ensure a good connection and will help prevent corrosion around the battery terminals.

Table of Contents

DCA-100SSJUPRE-SETUP

CAUTION :

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

DCA-100SSJU — PARTS AND OPERATION MANUAL (STD)— REV. #2 (05/03/01) — PAGE 47

Image 47
Contents MQ Power DCA-100SSJU Whisperwatttm Generator Table of Contents Heres HOW to GET Help Table of Contents USA Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryEmergencies Maintenance SafetyRules for Safe Operation TransportingDCA-100SSJU Towing Rules for Safe Operation Towing Safety PrecautionsCoupler Type of hitch used on the trailer for towing DCA-100SSJU -TRAILER-SAFETY GuidelinesExplanation of Chart TRLR-10XF DCA-100SSJU -TRAILER-SPECIFICATIONSElectrical DCA-100SSJU -TRAILER-SPECIFICATIONSElectric Brakes Electric Brake AdjustmentDCA-100SSJU Trailer Braking System BrakesHydraulic/Air/Surge Brakes DCA-100SSJU -TRAILER Braking SystemSuspension DCA-100SSJU Trailer Tires & SuspensionTires/Wheels/Lug Nuts Tire Wear/InflationNever use an pneumatic air gun to tighten wheel lug nuts Torque Ft.-LbsLug Nut Torque Requirements DCA-100SSJU -TRAILERWIRING Diagrams Electric Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingHydraulic Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingDCA-100SSJU Generator Decals DCA-100SSJU Generator Decals Generator Specifications DCA-100SSJU SpecificationsDCA-100SSJU General Information Major Components DCA-100SSJU Major ComponentsDimensions DCA-100SSJU Dimensions TOP, Side and FrontPage Control Panel DCA-100SSJU Control PanelDCA-100SSJU Control Panel Engine Operating Panel DCA-100SSJU Engine Operating Panel with KEYFuel Gauge Indicates amount of diesel fuel available DCA-100SSJU Engine Operating Panel with KEYDCA-100SSJU Engine Operating Panel with Mpec DCA-100SSJU Engine Operating Panel with Mpec Volt Receptacle Connecting LoadDCA-100SSJU Output Terminal Panel Overview Circuit BreakersDCA-100SSJU Output Terminal Panel Overview DCA-100SSJU Outputterminal Panel Overview AC Ammeter How to read the output terminal gauges480/240V Hard Wire Hookup 240/120V Hard Wire HookupSingle Phase 277V, 254V, or Single Phase 480V, 440V, or 416 VoltPhase, 480V, 440V, or 416 Volt Single Phase 139V, 127V, or Single Phase 240V, 220V, or 208 VoltPhase, 240V, 220V, or 208 Volt Single Phase, 240 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase 120 Volt Indoor Installation DCA-100SSJU InstallationOutdoor Installation Typical Generator Grounding Application DCA-100SSJU InstallationDCA-100SSJU PRE-SETUP Coolant DCA-100SSJU PRE-SETUPLubrication Oil ManualOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension Piping and Hose Connection Battery Cable InstallationWhen connecting battery do the following WiringWatts =1.732 x Voltage x Amperage Single Phase LoadThree Phase Load DCA-100SSJU Load ApplicationBefore Starting Generator and Control Panel Before Starting EngineClose all engine enclosure doors Figure DCA-100SSJU Generator START-UP Procedure ManualFrequency Meter Hz Place the Off/Manual/Auto switch in the Auto position up DCA-100SSJU Generator START-UP Procedure AutoDCA-100SSJU Generator Shutdown Procedure DCA-100SSJU Maintenance Inspection / Maintenance DCA-100SSJU MaintenanceEngine Troubleshooting DCA-100SSJU -TROUBLESHOOTING EngineDCA-100SSJU -TROUBLESHOOTING Engine Engine & Generator Troubleshooting DCA-100SSJU -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-100SSJU Troubleshooting MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnN7400296~ Qty DescriptionDCA-100SSJU --- Generator Assy Generator Assy GeneratorDCA-100SSJU --- Control BOX Assy DCA-100SSJU Control BOX Assy DCA-100SSJU --- Control BOX Assy DCA-100SSJU DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy QTY Remarks 700001 to 7400296~ DCA-100SSJU --- Engine Operating Panel AssyEngine Operating Panel Assy DCA-100SSJU --- Output Terminal Assy DCA-100SSJU Output Terminal Assy Output TerminalDCA-100SSJU --- Battery Assy 0040006000 06022201964D-2 0602220921DCA-100SSJU --- Muffler Assy DCA-100SSJU Muffler Assy DCA-100SSJU --- Fuel Tank Assy N74000027~ 031108160 0605505070020108060 0273080000Enclosure Assy DCA-100SSJU --- Enclosure AssyEnclosure Assy DCA-100SSJU --- Enclosure Assy 0601850097 Replaces M3453200102N7400027 to 011208060DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Decals Decals Effective July 1 Page Heres HOW to GET Help