Multiquip DCA-100SSJU Single Phase 480V, 440V, or 416 Volt, Phase, 480V, 440V, or 416 Volt

Page 39

Table of Contents

DCA-100SSJU — OUTPUT TERMINAL PANEL OVERVIEW

Voltage Selector Switch- 3 Phase 480/277V Position The following are additional voltages available when the voltage selector switch is in the 3 phase 480/277V position. (See figure 26 below.)

FIGURE 27. Voltage

Selector Switch 270/120V

Single Phase

Position

Single Phase: 480V, 440V, or 416 Volt

The following connection, with the voltage selector switch locked into the 3 phase 480/277V position (See Figure 26), can offer SINGLE PHASE power at 480V, 440V, or 416V.

After hooking up the hard wires to the lugs as shown in figure 29 below, 480V will be the voltage with the Voltage Regulator Knob turned toward maximum. 440 volt will be reached when the Voltage Regulator Knob is turned down, and 416 volt when the Voltage Regulator Knob is toward the lowest setting (See Figure 27).

FIGURE 26. Voltage Selector Switch 480/277V Single Phase

FIGURE 29. Hard Wire Hookup for Single Phase 480V, 440V,

Position

or 416V

3 Phase, 480V, 440V, or 416 Volt

The following connection, with the voltage selector switch locked into the 3 phase 480/277V position (See Figure 26), can offer THREE PHASE power at 480V, 440V, or 416V.

After hooking up the hard wires to the lugs as shown in figure 28 below, 480V will be the voltage with the Voltage Regulator Knob turned toward maximum. 440 volt will be reached when the Voltage Regulator Knob is turned down, and 416 volt when the Voltage Regulator Knob is toward the lowest setting (See Figure 27).

Single Phase: 277V, 254V, or 240V

The following connection, with the voltage selector switch locked into the 3 phase 480/277V position (See Figure 26), can offer SINGLE PHASE power at 277V, 254V, or 240V.

After hooking up the hard wires to the lugs as shown in figure 30 below, 277V will be the voltage with the Voltage Regulator Knob turned toward maximum. 254 volt will be reached when the Voltage Regulator Knob is turned down, and 240 volt when the Voltage Regulator Knob is toward the lowest setting (See Figure 27).

FIGURE 28. Hard Wire Hook-up for Three Phase 480V, 440V,

FIGURE 30. Hard Wire Hookup for Single Phase 277V, 254V,

or 416V

 

or 240V

DCA-100SSJU — PARTS AND OPERATION MANUAL (STD)— REV. #2 (05/03/01) — PAGE 39

Image 39
Contents MQ Power DCA-100SSJU Whisperwatttm Generator Table of Contents Heres HOW to GET Help Table of Contents USA Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryEmergencies Maintenance SafetyRules for Safe Operation TransportingDCA-100SSJU Towing Rules for Safe Operation Towing Safety PrecautionsDCA-100SSJU -TRAILER-SAFETY Guidelines Explanation of ChartCoupler Type of hitch used on the trailer for towing TRLR-10XF DCA-100SSJU -TRAILER-SPECIFICATIONSElectrical DCA-100SSJU -TRAILER-SPECIFICATIONSElectric Brakes Electric Brake AdjustmentDCA-100SSJU Trailer Braking System BrakesHydraulic/Air/Surge Brakes DCA-100SSJU -TRAILER Braking SystemSuspension DCA-100SSJU Trailer Tires & SuspensionTires/Wheels/Lug Nuts Tire Wear/InflationTorque Ft.-Lbs Lug Nut Torque RequirementsNever use an pneumatic air gun to tighten wheel lug nuts DCA-100SSJU -TRAILERWIRING Diagrams Electric Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingHydraulic Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingDCA-100SSJU Generator Decals DCA-100SSJU Generator Decals Generator Specifications DCA-100SSJU SpecificationsDCA-100SSJU General Information Major Components DCA-100SSJU Major ComponentsDimensions DCA-100SSJU Dimensions TOP, Side and FrontPage Control Panel DCA-100SSJU Control PanelDCA-100SSJU Control Panel Engine Operating Panel DCA-100SSJU Engine Operating Panel with KEYFuel Gauge Indicates amount of diesel fuel available DCA-100SSJU Engine Operating Panel with KEYDCA-100SSJU Engine Operating Panel with Mpec DCA-100SSJU Engine Operating Panel with Mpec Volt Receptacle Connecting LoadDCA-100SSJU Output Terminal Panel Overview Circuit BreakersDCA-100SSJU Output Terminal Panel Overview DCA-100SSJU Outputterminal Panel Overview AC Ammeter How to read the output terminal gauges480/240V Hard Wire Hookup 240/120V Hard Wire HookupSingle Phase 480V, 440V, or 416 Volt Phase, 480V, 440V, or 416 VoltSingle Phase 277V, 254V, or Single Phase 240V, 220V, or 208 Volt Phase, 240V, 220V, or 208 VoltSingle Phase 139V, 127V, or Voltage Selector Switch- Single Phase 240/120V Position Single Phase 120 VoltSingle Phase, 240 Volt DCA-100SSJU Installation Outdoor InstallationIndoor Installation Typical Generator Grounding Application DCA-100SSJU InstallationDCA-100SSJU PRE-SETUP Coolant DCA-100SSJU PRE-SETUPLubrication Oil ManualCleaning the Radiator Air Cleaner Fan Belt TensionOperation in Freezing Weather Piping and Hose Connection Battery Cable InstallationWhen connecting battery do the following WiringWatts =1.732 x Voltage x Amperage Single Phase LoadThree Phase Load DCA-100SSJU Load ApplicationBefore Starting Generator and Control Panel Before Starting EngineClose all engine enclosure doors Figure DCA-100SSJU Generator START-UP Procedure ManualFrequency Meter Hz Place the Off/Manual/Auto switch in the Auto position up DCA-100SSJU Generator START-UP Procedure AutoDCA-100SSJU Generator Shutdown Procedure DCA-100SSJU Maintenance Inspection / Maintenance DCA-100SSJU MaintenanceEngine Troubleshooting DCA-100SSJU -TROUBLESHOOTING EngineDCA-100SSJU -TROUBLESHOOTING Engine Engine & Generator Troubleshooting DCA-100SSJU -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-100SSJU Troubleshooting MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnN7400296~ Qty DescriptionDCA-100SSJU --- Generator Assy Generator Assy GeneratorDCA-100SSJU --- Control BOX Assy DCA-100SSJU Control BOX Assy DCA-100SSJU --- Control BOX Assy DCA-100SSJU DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy QTY Remarks 700001 to 7400296~ DCA-100SSJU --- Engine Operating Panel AssyEngine Operating Panel Assy DCA-100SSJU --- Output Terminal Assy DCA-100SSJU Output Terminal Assy Output TerminalDCA-100SSJU --- Battery Assy 0040006000 06022201964D-2 0602220921DCA-100SSJU --- Muffler Assy DCA-100SSJU Muffler Assy DCA-100SSJU --- Fuel Tank Assy N74000027~ 031108160 0605505070020108060 0273080000Enclosure Assy DCA-100SSJU --- Enclosure AssyEnclosure Assy DCA-100SSJU --- Enclosure Assy 0601850097 Replaces M3453200102N7400027 to 011208060DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Decals Decals Effective July 1 Page Heres HOW to GET Help