Multiquip operation manual DCA-100SSJU Engine Operating Panel with KEY

Page 31

Table of Contents

DCA-100SSJU — ENGINE OPERATING PANEL (WITH KEY)

The definitions below describe the controls and functions of the DCA-100SSJU " Engine Operating Panel " (Figure 9).

1.Panel light - Normally used in dark places or at night. When activated, panel will luminate. When the generator is not in use, turn the panel light switch to the ‘OFF’ position.

2.Panel light switch- When activated, will turn on control panel light.

3.Oil Pressure Gauge – Normal operation should be about 25 psi. When starting the generator the oil pressure may read a bit higher, but after the engine warms up the oil pressure should return to normal.

4.WaterTemperature Gauge – During normal operation this gauge be should read between 165oF to 215oF.

5.Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

6.Fuel Gauge - Indicates amount of diesel fuel available.

7.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

8.EngineThrottle Lever- This lever will change the speed of the engine from high to low.

9.Pre-Heat Button – Press hold this button to start the engine in cold conditions.

10.Starter Switch with Key – This switch has three different positions: Stop-Turn the key to stop the engine. Start-Turn the key to this position to start the engine. Release the key once the engine has started and it will automatically return to the operating position.

11.Oil Pressure Indicator - This indicator lets the operator know the oil pressure is dangerously high or low and will shut down the engine.

12.Water Temperature Indicator - This indicator lets the operator know the water temperature is dangerously high and will shut down the engine.

DCA-100SSJU — PARTS AND OPERATION MANUAL (STD)— REV. #2 (05/03/01) — PAGE 31

Image 31
Contents MQ Power DCA-100SSJU Whisperwatttm Generator Table of Contents Heres HOW to GET Help Table of Contents USA Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryEmergencies Maintenance SafetyRules for Safe Operation TransportingDCA-100SSJU Towing Rules for Safe Operation Towing Safety PrecautionsExplanation of Chart DCA-100SSJU -TRAILER-SAFETY GuidelinesCoupler Type of hitch used on the trailer for towing TRLR-10XF DCA-100SSJU -TRAILER-SPECIFICATIONSElectrical DCA-100SSJU -TRAILER-SPECIFICATIONSElectric Brakes Electric Brake AdjustmentDCA-100SSJU Trailer Braking System BrakesHydraulic/Air/Surge Brakes DCA-100SSJU -TRAILER Braking SystemSuspension DCA-100SSJU Trailer Tires & SuspensionTires/Wheels/Lug Nuts Tire Wear/InflationLug Nut Torque Requirements Torque Ft.-LbsNever use an pneumatic air gun to tighten wheel lug nuts DCA-100SSJU -TRAILERWIRING Diagrams Electric Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingHydraulic Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingDCA-100SSJU Generator Decals DCA-100SSJU Generator Decals Generator Specifications DCA-100SSJU SpecificationsDCA-100SSJU General Information Major Components DCA-100SSJU Major ComponentsDimensions DCA-100SSJU Dimensions TOP, Side and FrontPage Control Panel DCA-100SSJU Control PanelDCA-100SSJU Control Panel Engine Operating Panel DCA-100SSJU Engine Operating Panel with KEYFuel Gauge Indicates amount of diesel fuel available DCA-100SSJU Engine Operating Panel with KEYDCA-100SSJU Engine Operating Panel with Mpec DCA-100SSJU Engine Operating Panel with Mpec Volt Receptacle Connecting LoadDCA-100SSJU Output Terminal Panel Overview Circuit BreakersDCA-100SSJU Output Terminal Panel Overview DCA-100SSJU Outputterminal Panel Overview AC Ammeter How to read the output terminal gauges480/240V Hard Wire Hookup 240/120V Hard Wire HookupPhase, 480V, 440V, or 416 Volt Single Phase 480V, 440V, or 416 VoltSingle Phase 277V, 254V, or Phase, 240V, 220V, or 208 Volt Single Phase 240V, 220V, or 208 VoltSingle Phase 139V, 127V, or Single Phase 120 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase, 240 Volt Outdoor Installation DCA-100SSJU InstallationIndoor Installation Typical Generator Grounding Application DCA-100SSJU InstallationDCA-100SSJU PRE-SETUP Coolant DCA-100SSJU PRE-SETUPLubrication Oil ManualAir Cleaner Fan Belt Tension Cleaning the RadiatorOperation in Freezing Weather Piping and Hose Connection Battery Cable InstallationWhen connecting battery do the following WiringWatts =1.732 x Voltage x Amperage Single Phase LoadThree Phase Load DCA-100SSJU Load ApplicationBefore Starting Generator and Control Panel Before Starting EngineClose all engine enclosure doors Figure DCA-100SSJU Generator START-UP Procedure ManualFrequency Meter Hz Place the Off/Manual/Auto switch in the Auto position up DCA-100SSJU Generator START-UP Procedure AutoDCA-100SSJU Generator Shutdown Procedure DCA-100SSJU Maintenance Inspection / Maintenance DCA-100SSJU MaintenanceEngine Troubleshooting DCA-100SSJU -TROUBLESHOOTING EngineDCA-100SSJU -TROUBLESHOOTING Engine Engine & Generator Troubleshooting DCA-100SSJU -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-100SSJU Troubleshooting MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnN7400296~ Qty DescriptionDCA-100SSJU --- Generator Assy Generator Assy GeneratorDCA-100SSJU --- Control BOX Assy DCA-100SSJU Control BOX Assy DCA-100SSJU --- Control BOX Assy DCA-100SSJU DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy QTY Remarks 700001 to 7400296~ DCA-100SSJU --- Engine Operating Panel AssyEngine Operating Panel Assy DCA-100SSJU --- Output Terminal Assy DCA-100SSJU Output Terminal Assy Output TerminalDCA-100SSJU --- Battery Assy 0040006000 06022201964D-2 0602220921DCA-100SSJU --- Muffler Assy DCA-100SSJU Muffler Assy DCA-100SSJU --- Fuel Tank Assy N74000027~ 031108160 0605505070020108060 0273080000Enclosure Assy DCA-100SSJU --- Enclosure AssyEnclosure Assy DCA-100SSJU --- Enclosure Assy 0601850097 Replaces M3453200102N7400027 to 011208060DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Decals Decals Effective July 1 Page Heres HOW to GET Help