Multiquip DCA-100SSJU operation manual Parts Ordering Procedures, Usa

Page 5

Table of Contents

PARTS ORDERING PROCEDURES

Dealer account number

Dealer name and address

Shipping address (if different than billing address)

Return fax number

Applicable model number

Quantity, part number and description of each part

Specify preferred method of shipment:

UPS Ground

UPS Second Day or Third Day* UPS Next Day*

Federal Express Priority One (please provide us with your Federal Express account number)*

Airborne Express*

Truck or parcel post

*Normally shipped the same day the order is received, if prior to 2PM west coast time.

Earn Extra Discounts when

you order by FAX!

All parts orders which include complete part numbers and are received by fax qualify for the following extra discounts:

Number of

 

line items ordered

Additional Discount

1-9 items

3%

10+ items**

5%

Get special freight allowances when you order 10 or more line items via FAX!**

UPS Ground Service at no charge for freight

PS Third Day Service at one-half of actual freight cost

No other allowances on freight shipped by any other carrier.

**Common nuts, bolts and washers (all items under $1.00 list price) do not count towards the 10+ line items.

*DISCOUNTS ARE SUBJECT TO CHANGE*

Fax order discount and UPS special programs revised June 1, 1995

Extra

Fax

Discount

USA

 

for

Domestic

 

 

Only

 

 

 

 

Dealers

 

UPS

 

 

 

only

Special

 

ed orders

 

For

fax

 

 

 

Now! Direct TOLL-FREE access

to our Parts Department!

Toll-free nationwide:

800-421-1244

Toll-free FAX:

800/6-PARTS-7800-672-7877

DCA-100SSJU — PARTS AND OPERATION MANUAL (STD)— REV. #2 (05/03/01) — PAGE 5

Image 5
Contents MQ Power DCA-100SSJU Whisperwatttm Generator Table of Contents Heres HOW to GET Help Table of Contents USA Parts Ordering ProceduresRules for Safe Operation General SafetyRadiator Rules for Safe OperationLoading and Unloading Crane BatteryRules for Safe Operation Maintenance SafetyTransporting EmergenciesDCA-100SSJU Towing Rules for Safe Operation Towing Safety PrecautionsCoupler Type of hitch used on the trailer for towing DCA-100SSJU -TRAILER-SAFETY GuidelinesExplanation of Chart TRLR-10XF DCA-100SSJU -TRAILER-SPECIFICATIONSElectrical DCA-100SSJU -TRAILER-SPECIFICATIONSDCA-100SSJU Trailer Braking System Electric Brake AdjustmentBrakes Electric BrakesHydraulic/Air/Surge Brakes DCA-100SSJU -TRAILER Braking SystemTires/Wheels/Lug Nuts DCA-100SSJU Trailer Tires & SuspensionTire Wear/Inflation SuspensionNever use an pneumatic air gun to tighten wheel lug nuts Torque Ft.-LbsLug Nut Torque Requirements DCA-100SSJU -TRAILERWIRING Diagrams Electric Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingHydraulic Brake Troubleshooting DCA-100SSJU -TRAILER-BRAKE TroubleshootingDCA-100SSJU Generator Decals DCA-100SSJU Generator Decals Generator Specifications DCA-100SSJU SpecificationsDCA-100SSJU General Information Major Components DCA-100SSJU Major ComponentsDimensions DCA-100SSJU Dimensions TOP, Side and FrontPage Control Panel DCA-100SSJU Control PanelDCA-100SSJU Control Panel Engine Operating Panel DCA-100SSJU Engine Operating Panel with KEYFuel Gauge Indicates amount of diesel fuel available DCA-100SSJU Engine Operating Panel with KEYDCA-100SSJU Engine Operating Panel with Mpec DCA-100SSJU Engine Operating Panel with Mpec DCA-100SSJU Output Terminal Panel Overview Connecting LoadCircuit Breakers Volt ReceptacleDCA-100SSJU Output Terminal Panel Overview DCA-100SSJU Outputterminal Panel Overview AC Ammeter How to read the output terminal gauges480/240V Hard Wire Hookup 240/120V Hard Wire HookupSingle Phase 277V, 254V, or Single Phase 480V, 440V, or 416 VoltPhase, 480V, 440V, or 416 Volt Single Phase 139V, 127V, or Single Phase 240V, 220V, or 208 VoltPhase, 240V, 220V, or 208 Volt Single Phase, 240 Volt Voltage Selector Switch- Single Phase 240/120V PositionSingle Phase 120 Volt Indoor Installation DCA-100SSJU InstallationOutdoor Installation Typical Generator Grounding Application DCA-100SSJU InstallationDCA-100SSJU PRE-SETUP Lubrication Oil DCA-100SSJU PRE-SETUPManual CoolantOperation in Freezing Weather Cleaning the RadiatorAir Cleaner Fan Belt Tension When connecting battery do the following Battery Cable InstallationWiring Piping and Hose ConnectionThree Phase Load Single Phase LoadDCA-100SSJU Load Application Watts =1.732 x Voltage x AmperageBefore Starting Generator and Control Panel Before Starting EngineClose all engine enclosure doors Figure DCA-100SSJU Generator START-UP Procedure ManualFrequency Meter Hz Place the Off/Manual/Auto switch in the Auto position up DCA-100SSJU Generator START-UP Procedure AutoDCA-100SSJU Generator Shutdown Procedure DCA-100SSJU Maintenance Inspection / Maintenance DCA-100SSJU MaintenanceEngine Troubleshooting DCA-100SSJU -TROUBLESHOOTING EngineDCA-100SSJU -TROUBLESHOOTING Engine Engine & Generator Troubleshooting DCA-100SSJU -TROUBLESHOOTING GENERATOR/ENGINEMpec Troubleshooting DCA-100SSJU Troubleshooting MpecItems Found In the Items Number Column Explanation of Code in Remarks ColumnN7400296~ Qty DescriptionDCA-100SSJU --- Generator Assy Generator Assy GeneratorDCA-100SSJU --- Control BOX Assy DCA-100SSJU Control BOX Assy DCA-100SSJU --- Control BOX Assy DCA-100SSJU DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy DCA-100SSJU Engine and Radiator Assy QTY Remarks 700001 to 7400296~ DCA-100SSJU --- Engine Operating Panel AssyEngine Operating Panel Assy DCA-100SSJU --- Output Terminal Assy DCA-100SSJU Output Terminal Assy Output TerminalDCA-100SSJU --- Battery Assy 4D-2 06022201960602220921 0040006000DCA-100SSJU --- Muffler Assy DCA-100SSJU Muffler Assy DCA-100SSJU --- Fuel Tank Assy 020108060 06055050700273080000 N74000027~ 031108160Enclosure Assy DCA-100SSJU --- Enclosure AssyEnclosure Assy DCA-100SSJU --- Enclosure Assy N7400027 to Replaces M3453200102011208060 0601850097DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Rubber Seal Assy DCA-100SSJU --- Decals Decals Effective July 1 Page Heres HOW to GET Help