WARNING

Airborne particles.

Can cause severe injury or blindness.

Wear protective goggles and clothing when using power tools, hand tools, or compressed air.

Tightening the hardware. Flying projectiles can cause severe injury or death. Loose hardware can cause the hardware or pulley to release from the generator set engine and can cause

personal injury. Retorque all crankshaft and rotor hardware after servicing. Do not loosen the crankshaft hardware or rotor thrubolt when making adjustments or servicing the generator set. Rotate the crankshaft manually in a clockwise direction only. Turning the crankshaft bolt or rotor thrubolt counterclockwise can loosen the hardware.

Servicing the generator set when it is operating. Exposed moving parts can cause severe injury or death. Keep hands, feet, hair, clothing, and test leads away from the belts and pulleys when the generator set is running. Replace guards, screens, and covers before operating the generator set.

Notice

NOTICE

This generator set has been rewired from its nameplate voltage to

246242

NOTICE

Voltage reconnection. Affix a notice to the generator set after reconnecting the set to a voltage different from the voltage on the nameplate. Order voltage reconnection decal 246242 from an authorized service distributor/dealer.

NOTICE

Hardware damage. The engine and generator set may use both American Standard and metric hardware. Use the correct size tools to prevent rounding of the bolt heads and nuts.

NOTICE

When replacing hardware, do not substitute with inferior grade hardware. Screws and nuts are available in different hardness ratings. To indicate hardness, American Standard hardware uses a series of markings, and metric hardware uses a numeric system. Check the markings on the bolt heads and nuts for identification.

NOTICE

Canadian installations only. For standby service connect the output of the generator set to a suitably rated transfer switch in accordance with Canadian Electrical Code, Part 1.

NOTICE

This generator set does not comply with United States Coast Guard (USCG) requirements and must not be used for marine applications. For marine installations use only generator sets specified for marine use. USCG Regulation 33CFR183 requires that a generator set must be ignition protected when used in a gasoline-fueled environment.

TP-6335 9/04

Safety Precautions and Instructions V

Image 9
Contents TP-6335 9/04 ModelPage Table of Contents Page Safety Precautions and Instructions BatteryAccidental Starting Exhaust System Engine Backfire/Flash FireFuel System Hazardous NoiseHazardous Voltage/ Electrical Shock Moving Parts Hot Parts246242 VI Safety Precautions and Instructions TP-6335 9/04 Generator Set Specifications Installation StandardsIntroduction Generator Set OperationIntroduction TP-6335 9/04 General Considerations Location and MountingLocation Vehicle-Floor MountingLocation and Mounting TP-6335 9/04 Cooling System High Water Temperature SwitchAir Requirements Block HeatersCooling System TP-6335 9/04 Exhaust System Planning Clearance RequirementsExhaust Piping, If Used Gasoline Fuel SystemFuel Filters or Strainers LP GasFuel Lines Fuel Pump Lift Capability Max., Gasoline Models Fuel Pump Lift and Fuel ConsumptionFuel System TP-6335 9/04 Electrical System Electrical ConnectionsAC Load Lead Connections Transfer Switch Connections Wire AC Circuit Circuit Breaker Considerations Circuit ProtectionElectrical Connections Circuit Breaker InstallationADC 2100 Continuous Power Mode Jumper CCA Battery and ConnectionsView B Remote ConnectionElectrical System TP-6335 9/04 Dimension Drawing, Gasoline Fuel System Installation DrawingDimension Drawing, LP Fuel System Dimension Drawing, Floor Template Installation Drawing TP-6335 9/04 Reconnection/Adjustments Four-Lead Reconnection 100--120-Volt, 2-Wire Configuration200--220--240-Volt, 2-Wire Configuration For Models with ADC Configuration Mode Time Out Advanced Digital Control ADCController Software Version Number Voltage Adjustment Adjusting the Voltage, Gain, and Volts/HzOn Figure Output Voltage Adjustment ModeFrom Figure V EController Configuration Controller Parameters N c V E 11 Save Mode after configuring generator set parameters Reconnection/Adjustments TP-6335 9/04 General Wattage Requirements Appendix a Generator Selection and Wattage RequirementsAnsi Appendix B AbbreviationsLCB Page Page By Kohler Co. All rights reserved