Kohler 13ERG, 15ERG, 10ERG Location and Mounting, General Considerations, Vehicle-Floor Mounting

Page 13

Section 2 Location and Mounting

2.1 General Considerations

Consider the following items concerning the generator set and Section 2.2 for the proposed location.

1.Select a generator set having adequate capacity to handle the electrical load.

2.Design the fuel system to prevent fuel starvation of the main or generator set engine.

3.Ensure that the exhaust system meets all safety requirements after installation.

4.Ensure compatibility of all electrical systems (battery, load, and remote switch) with the vehicle’s electrical systems.

2.2 Location

Note: This generator set is not designed for installation in a compartment or enclosure.

Before making final plans for locating the generator set, ensure the following:

1.The location has sufficient room to maintain required minimum clearances.

2.The location provides enough air flow to allow required cooling and combustion.

3.The location can support the generator set weight.

4.The location provides ample room for routine service of the generator set’s engine, controller, cooling system, and fuel system components.

See the current generator set specification sheet or Section 7 of this manual for generator set dimensions and weights.

For angular operating limits, consult the operation manual.

2.3 Vehicle-Floor Mounting

Install the Kohler mobile generator set on an open vehicle’s floor or truck bed. Follow the guidelines below. Contact an authorized Kohler service distributor/dealer with your specific application questions.

Minimum clearance. Allow clearance for vibration and cooling during operation. Minimum clearance for vibration (top, front, rear, and sides) is 38 mm (1 1/2 in.). Keep the radiator end unobstructed for proper air flow.

Additional clearance. Generator set service requires more clearance than 38 mm (1 1/2 in.). Design the mounting location to allow for sufficient room to easily remove the generator set to perform major service.

Securely fasten the generator set to avoid unwanted movement from vibration and road shock. Attach the generator set vibromounts directly to the vehicle’s frame. See Figure 2-1 for vibromount installation.

 

Vibromount

 

 

 

Top View

 

 

 

 

 

Vibromount

 

 

 

Side View

 

 

 

1

2

3

 

 

 

 

4

 

 

 

 

5

 

Color

Mounting Location

 

6

 

Purple (2)

Engine end

7

 

 

White (2)

Generator end

 

 

 

 

 

ADV6816-

1.

Lock nut

 

 

 

2.

Flat washer (7/16 x 1)

 

 

3.

Generator set frame

 

 

4.

Vibromount

 

 

 

5.

Vehicle frame

 

 

 

6.

Flat washer (13/32 x 2)

 

 

7.

Screw (3/8--16 x 2--1/4)

 

 

Figure 2-1 Vibromount Installation

TP-6335 9/04

Location and Mounting 3

Image 13
Contents TP-6335 9/04 ModelPage Table of Contents Page Battery Safety Precautions and InstructionsAccidental Starting Exhaust System Engine Backfire/Flash FireHazardous Noise Fuel SystemHazardous Voltage/ Electrical Shock Moving Parts Hot Parts246242 VI Safety Precautions and Instructions TP-6335 9/04 Generator Set Specifications Installation StandardsIntroduction Generator Set OperationIntroduction TP-6335 9/04 General Considerations Location and MountingLocation Vehicle-Floor MountingLocation and Mounting TP-6335 9/04 Cooling System High Water Temperature SwitchAir Requirements Block HeatersCooling System TP-6335 9/04 Exhaust System Clearance Requirements PlanningExhaust Piping, If Used Gasoline Fuel SystemLP Gas Fuel Filters or StrainersFuel Lines Fuel Pump Lift Capability Max., Gasoline Models Fuel Pump Lift and Fuel ConsumptionFuel System TP-6335 9/04 Electrical Connections Electrical SystemAC Load Lead Connections Transfer Switch Connections Wire AC Circuit Circuit Breaker Considerations Circuit ProtectionElectrical Connections Circuit Breaker InstallationADC 2100 Continuous Power Mode Jumper CCA Battery and ConnectionsView B Remote ConnectionElectrical System TP-6335 9/04 Dimension Drawing, Gasoline Fuel System Installation DrawingDimension Drawing, LP Fuel System Dimension Drawing, Floor Template Installation Drawing TP-6335 9/04 Reconnection/Adjustments Four-Lead Reconnection 100--120-Volt, 2-Wire Configuration200--220--240-Volt, 2-Wire Configuration For Models with ADC Advanced Digital Control ADC Configuration Mode Time OutController Software Version Number Voltage Adjustment Adjusting the Voltage, Gain, and Volts/HzOn Figure Output Voltage Adjustment ModeFrom Figure V EController Configuration Controller Parameters N c V E 11 Save Mode after configuring generator set parameters Reconnection/Adjustments TP-6335 9/04 General Wattage Requirements Appendix a Generator Selection and Wattage RequirementsAnsi Appendix B AbbreviationsLCB Page Page By Kohler Co. All rights reserved