NovaJet 800 Series Service Manual

Calibration Menu

*

About

Diagnostics Menu

 

Cartridge Info.

 

 

Test Print

 

 

Exit

Figure 3-23. Service Menu.

3.Select the “Calibration Menu” from the Service Menu.

4.The Calibration Menu shown in Figure 3-24 is where the deadband tests are performed. Select “Slow Db Test” to run the slow deadband test.

Deadband Test

*

 

Slow Db Test

Slow Deadband

Single Line Test

 

All Lines Test

Exit

Figure 3-24. Calibration (Deadband) Menu.

5.When the plot is complete, select “Slow Deadband” at the Calibration Menu. This brings up the options menu for the slow deadband adjustment. This menu is similiar to the menu depicted in Figure 3-21.

6.Observe the plot and using either “Prev Option” or “Next Option”, rotate through the selections until the value you want is selected. Press “Ok” to accept the selection and return to the Calibration Menu.

Maintenance 3-36

Page 88
Image 88